Date: 3/12/2021
<br /> Made By: SGT
<br /> Project: Four Corners-All Buildings
<br /> Description: Stud Bearing Data
<br /> Note:Refer to following calcs for capacities
<br /> Stud Bearing Capacitices 9'-0"Stud Height
<br /> Area*Cb Plate Crushing Exterior Interior
<br /> Stud Size and Number z
<br /> (in ) (Ibs) (Ibs) (Ibs)
<br /> 2x4 DF#2 Stud 6.5625 4,100 NA 1,990
<br /> (2)2x4 DF#2 Studs 11.8125 7,380 NA 3,990
<br /> (3)2x4 DF#2 Stud 17.0625 10,660 NA 5,990
<br /> 2x6 DF#2 Stud 10.3125 6,440 5,850 5,360
<br /> (2)2x6 DF#2 Stud 18.5625 11,600 11,750 10,740
<br /> (3)2x6 DF#2 Stud 26.8125 16,750 NA 16,000
<br /> *The above calcuations are base on plate crushing on Pressure Treated DF#2 Base Plate
<br /> Fpc= 625 psi
<br /> Tables select minimum value
<br /> 2x4 Stud Bearing Wall Capacitices 9'-0"Stud Height of calculated stud capacity and
<br /> z Plate Crushing Exterior Interior plate crushing for determining
<br /> Stud Size and Number Area (in ) (plf) (plf) (plf)
<br /> 2x4 DF#2 Stud @ 16"o.c. 6.5625 3,070 NA 1,490 bearing wall capacity.
<br /> 2x4 DF#2 Stud @ 12"o.c. 6.5625 4,100 NA 1,990
<br /> 2x4 DF#2 Stud @ 8"o.c. 6.5625 6,140 NA 2,980
<br /> (2)2x4 DF#2 Studs @ 12"o.c. 11.8125 7,380 NA 1 3,990
<br /> 2x6 Stud Bearing Wall Capacitices 9'-0"Stud Height
<br /> z Plate Crushing Exterior Interior
<br /> Stud Size and Number Area (in ) (plf) (plf) (plf)
<br /> 2x6 DF#2 Stud @ 16"o.c. 10.3125 4,830 4,380 4,020
<br /> 2x6 DF#2 Stud @ 12"o.c. 10.3125 6,440 5,850 5,360
<br /> 2x6 DF#2 Stud @ 8"o.c. 10.3125 9,650 8,770 8,030 Tables select minimum value
<br /> (2)2x6 DF#2 Stud @ 12"o.c. 18.5625 11,600 11,750 10,740 of calculated stud capacity at
<br /> 12" O.C. including lateral wind
<br /> pressure and extrapolates it for
<br /> 2x4 Built-up Post Bearing Capacitices 9'-0"Stud Height the different stud spacing.
<br /> z Plate Crushing Exterior Interior
<br /> Stud Size and Number Area (in ) (Ibs) (Ibs) (plf)
<br /> 2x4 DF#2 Stud 6.5625 4,100 NA 1,990
<br /> (2)2x4 DF#2 Studs 11.8125 7,380 NA 3,990
<br /> (3)2x4 DF#2 Stud 17.0625 10,660 NA 5,990
<br /> 2x6 Built-up Post Bearing Capacitices 9'-0"Stud Height
<br /> z Plate Crushing Exterior Interior
<br /> Stud Size and Number Area (in ) (Ibs) (Ibs) (plf)
<br /> 2x6 DF#2 Stud 10.3125 6,440 5,850 5,360
<br /> (2)2x6 DF#2 Stud 18.5625 11,600 11,750 10,740
<br /> (3)2x6 DF#2 Stud 26.8125 16,750 NA 16,000
<br />
|