Laserfiche WebLink
Date: 3/12/2021 <br /> Made By: SGT <br /> Project: Four Corners-All Buildings <br /> Description: Stud Bearing Data <br /> Note:Refer to following calcs for capacities <br /> Stud Bearing Capacitices 9'-0"Stud Height <br /> Area*Cb Plate Crushing Exterior Interior <br /> Stud Size and Number z <br /> (in ) (Ibs) (Ibs) (Ibs) <br /> 2x4 DF#2 Stud 6.5625 4,100 NA 1,990 <br /> (2)2x4 DF#2 Studs 11.8125 7,380 NA 3,990 <br /> (3)2x4 DF#2 Stud 17.0625 10,660 NA 5,990 <br /> 2x6 DF#2 Stud 10.3125 6,440 5,850 5,360 <br /> (2)2x6 DF#2 Stud 18.5625 11,600 11,750 10,740 <br /> (3)2x6 DF#2 Stud 26.8125 16,750 NA 16,000 <br /> *The above calcuations are base on plate crushing on Pressure Treated DF#2 Base Plate <br /> Fpc= 625 psi <br /> Tables select minimum value <br /> 2x4 Stud Bearing Wall Capacitices 9'-0"Stud Height of calculated stud capacity and <br /> z Plate Crushing Exterior Interior plate crushing for determining <br /> Stud Size and Number Area (in ) (plf) (plf) (plf) <br /> 2x4 DF#2 Stud @ 16"o.c. 6.5625 3,070 NA 1,490 bearing wall capacity. <br /> 2x4 DF#2 Stud @ 12"o.c. 6.5625 4,100 NA 1,990 <br /> 2x4 DF#2 Stud @ 8"o.c. 6.5625 6,140 NA 2,980 <br /> (2)2x4 DF#2 Studs @ 12"o.c. 11.8125 7,380 NA 1 3,990 <br /> 2x6 Stud Bearing Wall Capacitices 9'-0"Stud Height <br /> z Plate Crushing Exterior Interior <br /> Stud Size and Number Area (in ) (plf) (plf) (plf) <br /> 2x6 DF#2 Stud @ 16"o.c. 10.3125 4,830 4,380 4,020 <br /> 2x6 DF#2 Stud @ 12"o.c. 10.3125 6,440 5,850 5,360 <br /> 2x6 DF#2 Stud @ 8"o.c. 10.3125 9,650 8,770 8,030 Tables select minimum value <br /> (2)2x6 DF#2 Stud @ 12"o.c. 18.5625 11,600 11,750 10,740 of calculated stud capacity at <br /> 12" O.C. including lateral wind <br /> pressure and extrapolates it for <br /> 2x4 Built-up Post Bearing Capacitices 9'-0"Stud Height the different stud spacing. <br /> z Plate Crushing Exterior Interior <br /> Stud Size and Number Area (in ) (Ibs) (Ibs) (plf) <br /> 2x4 DF#2 Stud 6.5625 4,100 NA 1,990 <br /> (2)2x4 DF#2 Studs 11.8125 7,380 NA 3,990 <br /> (3)2x4 DF#2 Stud 17.0625 10,660 NA 5,990 <br /> 2x6 Built-up Post Bearing Capacitices 9'-0"Stud Height <br /> z Plate Crushing Exterior Interior <br /> Stud Size and Number Area (in ) (Ibs) (Ibs) (plf) <br /> 2x6 DF#2 Stud 10.3125 6,440 5,850 5,360 <br /> (2)2x6 DF#2 Stud 18.5625 11,600 11,750 10,740 <br /> (3)2x6 DF#2 Stud 26.8125 16,750 NA 16,000 <br />