My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8102 EVERGREEN WAY EVERETT 4 CORNERS - BLDG A 2025-07-28
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG A
>
8102 EVERGREEN WAY EVERETT 4 CORNERS - BLDG A 2025-07-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2025 7:29:28 AM
Creation date
6/17/2025 9:22:40 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG A
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
527
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EVERETT February 26, 2021 <br /> WAS H I N G TO N Seth Terry <br /> setht@johnsonbraund.com <br /> Johnson Braund Architects <br /> 15200 52"d Ave S, STE 300 <br /> Seattle, WA 98188 <br /> Owner: Four Corners, LLC <br /> Job Address: 8104 Evergreen Way, Bldg A <br /> Plan Check No: B2010-048 <br /> RE: Building Permit Review Letter <br /> Dear Mr.Terry, <br /> In response to the application for a building permit, the plans have been <br /> examined and you are advised that revisions may be necessary before a permit <br /> can be issued. Please review and respond to the comments below. <br /> ARCHITECTURAL <br /> 1. A multi-family residential unit is being constructed and is subject to the <br /> requirements of RCW 64.55. Please complete the RCW 64.55 Building Envelope <br /> Submittal worksheet. <br /> 2. On Sheet A020,total on-site parking stalls provided (684 stalls) in an R-2 <br /> occupancy are greater than (20). Per IBC 427.2, 5%of the parking spaces are <br /> required to have electrical vehicle charging infrastructure. Please clarify and <br /> revise drawings as required as this infrastructure appears to be missing. IBC <br /> 427. <br /> STRUCTURAL <br /> 3. On Sheet S1,the Design Criteria notes a redundancy factor of 1.0. However, <br /> the design permit calculations on page ETABS-1 notes that a redundancy factor <br /> 1.3 is being used on the concrete design permit calculations. Please clarify <br /> which redundancy factor is being used to design the concrete lateral force <br /> resisting system. <br /> PERMIT SERVICES 4. On Sheet S1, some of the wind design criteria such as the component & <br /> cladding wind pressures and importance factor appear to be missing. Please <br /> Q3200 Cedar Street clarify and add this information as required per IBC 1603.1.4. <br /> Everett,WA 98201 <br /> 5. On Sheet S1, some of the earthquake design criteria such as the base shear, <br /> 425.257.8857 seismic response coefficient analysis procedure, and importance factor <br /> 425.257.8857 fax p � Y � p p appear <br /> to be missing. Please clarify and add this information as required per IBC <br /> ® everetteps@everettwa.gov 1603.1.5. <br /> `dob' everettwa.gov/permits <br /> Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.