WoodWorks® Shearwalls 2352.wsw Feb.20,2023 13:29:46 <br /> HOLD-DOWN DESIGN(flexible seismic design) <br /> Level 1 Tensile ASD <br /> Line- Location[ft] Holddown Force[Ibs] Cap Crit <br /> Wall Posit'n X Y Shear Dead Ev Cmb'd Hold-down [lbs] Resp. <br /> Line 1 <br /> ✓ Elem 0.00 -11.62 524 541 136 119 Refer to upper level <br /> 1-1 R Op 1 0.00 -3.87 3128 215 54 2967 Refer to upper level <br /> 1-1 R End 0.00 -0.12 3652 486 122 3288 HDUB-SDS2. 6765 0.49 <br /> Line 2 <br /> ✓ Elem 24.50 -11.37 627 621 156 162 Refer to upper level <br /> 2-1 R Op 1 24.50 -3.87 2846 2846 HDU8-SDS2. 6765 0.42 <br /> 2-1 R End 24.50 -0.12 3473 621 136 3008 HDU8-SDS2. 6765 0.44 <br /> Line A <br /> A-1 L End 0.12 -11.50 513 330 83 266 HDU2-SDS2. 3075 0.09 <br /> ✓ Elem 8.62 -11.50 1002 1002 Refer to upper level <br /> A-1 L Op 1 10.88 -11.50 527 420 106 213 HDU2-SDS2. 3075 0.07 <br /> A-1 R Op 1 14.13 -11.50 503 405 102 200 HDU2-SDS2. 3075 0.07 <br /> ✓ Elem 19.38 -11.50 1002 1002 Refer to upper level <br /> A-1 R End 24.38 -11.50 488 315 79 253 HDU2-SDS2. 3075 0.08 <br /> Line B <br /> B-1 L End 0.12 0.00 2226 120 30 2136 HDU2-SDS2. 3075 0.69 <br /> B-1 L Op 1 3.88 0.00 721 615 155 261 HDU2-SDS2. 3075 0.08 <br /> B-1 R Op 1 20.63 0.00 1197 615 155 737 HDU2-SDS2. 3075 0.24 <br /> B-1 R End 24.38 0.00 2702 120 30 2612 HD02-SDS2. 3075 0.85 <br /> Level 2 Tensile ASD <br /> Line- Location[ft] Holddown Force[lbs] Cap Crit <br /> Wall , Posit'n X Y Shear Dead Ev Cmb'd Hold-down [Ibs] Resp. <br /> Line 1 <br /> 1-1 L End 0.00 -11.37 135 <br /> 1-1 R End 0.00 -9.12 135 <br /> 1-2 L End 0.00 -8.87 806 486 122 443 HDU2-SDS2. 3075 0.14 <br /> 1-2 R End 0.00 -0.12 806 486 122 443 HDU2-SDS2. 3075 0.14 <br /> Line 2 <br /> 2-1 L End 24.50 -11.37 627 621 156 162 HDU2-SDS2. 3075 0.05 <br /> 2-1 R End 24.50 -0.12 627 621 156 162 HDU2-SDS2. 3075 0.05 <br /> Line A <br /> A-2 L End 8.62 -11.50 1002 1002 HDU2-SDS2. 3075 0.33 <br /> A-2 R End 19.38 -11.53 1002 1002 HDJ2-SDS2. 3075 3.33 <br /> Line B <br /> B-1 R Op 1 4.13 0.00 1375 1375 HDU2-SDS2. 3075 0.45 <br /> B-i L Op 2 8.38 0.00 1375 1375 HDU2-SDS2. 3075 0.45 <br /> B-1 R Op 2 20.63 0.00 931 931 HDU2-SDS2. 3075 0.30 <br /> B-1 R End 24.38 0.00 931 931 HDU2-SDS2. 3075 0.30 <br /> Legend: <br /> Line-Wall: <br /> At wall or opening-Shearline and wall number <br /> At vertical element-Shearline <br /> Posit'n- Position of stud that hold-down is attached to: <br /> V Elem- Vertical element:column or strengthened studs required where not at wall end or opening <br /> L or R End-At left or right wall end <br /> L or R Op n- At left or right side of opening n <br /> t @ Op n- Uplift force tat opening n from offset opening in perforated wall above,from SDPWS 4.3.6.2.1 <br /> Location-Co-ordinates in Plan View <br /> Hold-down Forces: <br /> Shear-Seismic shear overturning component,factored for ASD by 0.7.For perforated walls, T from SDPWS 4.3-8 is used <br /> Dead-Dead load resisting component,factored for ASD by 0.60 <br /> Ev-Vertical seismic load effect from ASCE 7 12.4.2.2=-0.2Sds x ASD seismic factor x unfactored D=0.252 x factored D.Refer to Seismic Information <br /> table for more details. <br /> Cmb'd-Sum of ASD-factored overturning,dead and vertical seismic forces.May also include the uplift force t from perforated walls from SDPWS <br /> 4.3.6.2.1 when openings are staggered. <br /> Hold-down-Device used from hold-down database <br /> Cap-Allowable ASD tension load <br /> Crit.Resp.-Critical Response=Combined ASD force/Allowable ASD tension load <br /> Notes: <br /> Combined force from ASCE 7 2.4.1 load combination 10=-(0.6D-0.7Ev+0.7Eh);Eh(from 12.4.2.1)=-shear overturning force <br /> Refer to Shear Results table for factor Co,and shearline dimensions table for the sum of Li,used to calculate tension force T for perforated walls from <br /> SDPWS Eqn.4.3-8. <br /> Designer is responsible for design of connection from wall to floor or foundation for shear force shown in Shear Results table.Refer to SDPWS 4.3.6.4.3 for <br /> foundation anchor bolt requirements. <br /> 27 <br /> Page 52 of 63 <br />