Laserfiche WebLink
WoodWorks® Shearwalls 2352.wsw Feb.20,2023 13:29:46 <br /> COLLECTOR FORCES(flexible seismic design) <br /> Level 1 Drag Strut Strap/Blocking <br /> Line- Position on Wall Location[ft] Force[Ibs] Force[Ibs] <br /> Wall or Opening X <--- <br /> Line 1 <br /> Shearline force 1404 1404 <br /> 1-1 Right Opening 1 0.00 -4.00 -915 915 <br /> Line 2 <br /> Shearline force 1404 1404 <br /> 2-1 Right Opening 1 24.50 -4.00 -915 915 <br /> Line A <br /> Shearline force 1404 1404 <br /> A-1 Left Opening 1 11.00 -11.50 95 -115 <br /> A-1 Right Opening 1 14.00 -11.50 -77 57 <br /> Line B <br /> Shearline force 1404 1404 <br /> B-1 Left Opening 1 4.00 0.00 869 -301 <br /> B-1 Right Opening 1 20.50 0.00 -77 644 <br /> Level 2 Drag Strut Strap/Blocking <br /> Line- Position on Wall Location[ft] Force[Ibs] Force[Ibs] <br /> Wall or Opening X <--- <br /> Line 1 <br /> Shearline force 910 910 <br /> 1-2 Left Wall End 0.00 -9.00 -198 198 <br /> Line 2 <br /> Shearline force 910 910 <br /> 2-1 Left Opening 1 24.50 -8.50 -276 276 <br /> 2-1 Right Opening 1 24.50 -2.50 230 -230 <br /> 2-1 Left Opening 1 24.50 -8.50 535 535 <br /> 2-1 Right Opening 1 24.50 -2.50 446 446 <br /> Line A <br /> Shearline force 910 910 <br /> A-2 Left Wall End 8.50 -11.50 -316 316 <br /> A-2 Right Wall End 19.50 -11.50 186 -186 <br /> Line B <br /> Shearline force 910 910 <br /> B-1 Right Opening 1 4.00 0.00 -149 149 <br /> B-1 Left Opening 2 8.50 0.00 224 -224 <br /> B-1 Right Opening 2 20.50 0.00 -222 222 <br /> Legend: <br /> Line-Wall-Shearline and wall number <br /> Position...-Side of opening or wall end that drag strut is attached to <br /> Location-Co-ordinates in Plan View <br /> Drag strut Force-Axial force in transfer element at openings,gaps,or changes in design shear along shearline.+:tension;-:compression. <br /> Based on ASD-factored shearline force shown.For SDC C-F,it is the greater of the design shearline force and the diaphragm force Fpx,added <br /> to shearline force from story above and to forces transferred from discontinuous shearlines factored by overstrength(omega)as per 12.10.1.1. <br /> Refer to Seismic Information table for diaphragm forces and omega factor. <br /> For SDC D-F,if horizontal torsional irregularities 2,3,or 4 are input,or vertical irregularity 4 detected or input,25%increase from 12.3.3.4 applied. <br /> For perforated walls,this force is converted to vmax using 4.3.6.4.1.1. <br /> Strap/Blocking Force-For force-transfer walls,force transferred from above and below opening to shearwall pier. <br /> ->Due to shearline force in the west-to-east or south-to-north direction <br /> <-Due to shearline force in the east-to-west or north-to-south direction <br /> 28 <br /> Page 53 of 63 <br />