SITE WORK GENERAL NOTES: <br />GENERAL NOTES: <br />ELECTRICAL INSTALLATION NOTES: <br />GREENFIELD GROUNDING NOTES: <br />1. <br />FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: <br />1. <br />ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT <br />1. <br />THE SUBCONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF <br />CONTRACTOR- MASTEC NETWORK SOLUTIONS <br />SPECIFICATIONS, NEC AND ALL APPLICABLE FEDERAL, STATE, AND LOCAL <br />1. <br />ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, <br />CONSTRUCTION. <br />SUBCONTRACTOR- GENERAL CONTRACTOR (CONSTRUCTION) <br />CODES/ORDINANCES. <br />RADIO, LIGHTNING PROTECTION AND AC POWER GES'S) SHALL BE <br />-qqmp-�t&t <br />CARRIER- AT&T <br />TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER <br />Mobility <br />2. <br />ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES WHERE <br />POLE OWNER- CITY OF EVERETT <br />2. <br />2. <br />CONDUIT ROUTINGS ARE SCHEMATIC. SUBCONTRACTOR SHALL INSTALL CONDUITS SO <br />BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. <br />ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES AND WHERE REQUIRED <br />OEM- ORIGINAL EQUIPMENT MANUFACTURER <br />THAT ACCESS TO EQUIPMENT IS NOT BLOCKED AND TRIP HAZARDS ARE ELIMINATED. <br />FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY <br />2. <br />THE SUBCONTRACTOR SHALL PERFORM IEEE FALL- OF-POTENTAL <br />CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE SUBCONTRACTOR WHEN <br />2. <br />PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING SUBCONTRACTOR SHALL VISIT THE CELL <br />3. <br />WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE <br />RESISTANCE TO EARTH TESTING (PER IEEE 1 100 AND 81) FOR GROUND <br />EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES, SUBCONTRACTOR SHALL <br />SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN <br />REQUIREMENTS OF THE NEC. HILTI EPDXY ANCHORS ARE REQUIRED BY AT&T. <br />ELECTRODE SYSTEMS, THE SUBCONTRACTOR SHALL FURNISH AND <br />PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE <br />BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND <br />INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE <br />LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING <br />SHALL BE BROUGHT TO THE ATTENTION OF CONTRACTOR AND AT&T. <br />4. <br />ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS <br />A TEST RESULT OF 5 OHMS OR LESS. <br />AND EXCAVATION. <br />REQUIRED BY THE NEC. <br />3. <br />ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL <br />3. <br />THE SUBCONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING <br />3. <br />ALL SITE WORK TO COMPLY WITH QAS-STD-10068 "INSTALLATION STANDARDS FOR <br />APPLICABLE CODES, REGULATIONS AND ORDINANCES. SUBCONTRACTOR SHALL ISSUE ALL <br />5. <br />CABLES SHALL NOT BE ROUTED THROUGH LADDER -STYLE CABLE TRAY RUNGS. <br />GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT <br />CONSTRUCTION ACTIVITIES ON MASTEC TOWER SITE" AND LATEST VERSION OF TIA 1019 <br />APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS <br />ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO <br />Network Solutions <br />"STANDARD FOR INSTALLATION, ALTERATION, AND MAINTENANCE OF ANTENNA SUPPORTING <br />AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE <br />6. <br />EACH END OF EVERY POWER, POWER PHASE CONDUCTOR (I.E., HOTS), GROUNDING AND <br />THE CONDUIT AND PROVIDE TESTING RESULTS. <br />STRUCTURES AND ANTENNAS." <br />WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND <br />T1 CONDUCTOR AND CABLE SHALL BE LABELED WITH COLOR -CODED INSULATION OR <br />UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND <br />ELECTRICAL TAPE (3M BRAND, 1 /2" PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, <br />4. <br />METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE <br />4. ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND <br />APPLICABLE REGULATIONS. <br />OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC AND OSHA. <br />ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY <br />PROJECT SPECIFICATIONS. <br />BONDING ACROSS THE DISCONTINUITY WITH #6 AWG COPPER WIRE UL <br />7. <br />ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH PLASTIC TAPE PER <br />APPROVED GROUNDING TYPE CONDUIT CLAMPS. <br />5. <br />IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE <br />4. <br />DRAWINGS PROVIDED HERE ARE NOT TO SCALE AND ARE INTENDED TO SHOW OUTLINE <br />COLOR SCHEDULE. ALL EQUIPMENT SHALL BE LABELED WITH THEIR VOLTAGE RATING, <br />�J i i'' v -r <br />REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. <br />ONLY. <br />PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING AND <br />5. <br />METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED <br />., c- i cr <br />1­ �� 1 1 16- <br />BRANCH CIRCUIT ID NUMBERS (I.E. PANEL BOARD AND CIRCUIT ID'S). <br />EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS <br />'-P'STR"CT"P` �E�„I C E�. <br />6. <br />ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH <br />5. <br />UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, <br />WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL <br />INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, <br />APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED <br />8. <br />PANEL BOARDS (ID NUMBERS) AND INTERNAL CIRCUIT BREAKERS (CIRCUIT ID NUMBERS) <br />BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS <br />2227 W PECOS RD, SUITE 4 <br />PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE <br />ON THE DRAWINGS. <br />SHALL BE CLEARLY LABELED WITH PLASTIC LABELS. <br />EQUIPMENT. <br />CHANDLER, AZ 85224 <br />EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF CONTRACTOR, OWNER AND/OR <br />LOCAL UTILITIES. <br />6. <br />"KITTING LIST" SUPPLIED WITH THE BID PACKAGE IDENTIFIES ITEMS THAT WILL BE SUPPLIED <br />9. <br />ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE <br />6. <br />EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER <br />BY CONTRACTOR. ITEMS NOT INCLUDED IN THE BILL OF MATERIALS AND KITTING LIST SHALL <br />SHARP EDGES. <br />GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT <br />7. <br />THE SUBCONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL <br />BE SUPPLIED BY THE SUBCONTRACTOR. <br />GROUND WIRES, 6 AWG STRANDED COPPER OR LARGER FOR INDOOR <br />SPECIFICATION FOR SITE SIGNAGE. <br />10. <br />POWER, CONTROL AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE <br />BTS; #2 AWG SOLID TINNED COPPER FOR OUTDOOR BTS. <br />7. <br />THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH <br />SINGLE CONDUCTOR (#14 AWG OR LARGER), 600 V, OIL RESISTANT THHN OR THWN-2, <br />8. <br />THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE BTS <br />MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. <br />CLASS B STRANDED COPPER CABLE RATED FOR 90° C (WET 8c DRY) OPERATION LISTED <br />7. <br />CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR <br />EQUIPMENT AND TOWER AREAS. <br />OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED UNLESS OTHERWISE <br />STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE OF THE <br />8. <br />IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, <br />SPECIFIED. <br />GROUND BUS ARE PERMITTED. <br />9. <br />NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN <br />THE SUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY <br />MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. <br />THE CONTRACTOR AND AT&T PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF <br />11. <br />SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE <br />8. <br />ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND <br />INSTALLATION. <br />CONDUCTOR (#6 AWG OR LARGER), 600V, OIL RESISTANT THHN OR THWN-2 GREEN <br />BARS AND THE GROUND RING SHALL BE #2 AWG SOLID TINNED <br />10. <br />THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE <br />CLASS B STRANDED COPPER CABLE RATED FOR 90° C (WET AND DRY) <br />COPPER UNLESS OTHERWISE INDICATED. <br />PRIOR TO FINISHED SURFACE APPLICATION. <br />9 <br />SUBCINSULATION <br />SHALL NE U OF � D <br />TIGR000ND <br />CCABLES ION <br />OPERATION LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED <br />WAEVT-004-B <br />AS STOR GNG <br />GROUNDING HOWN THE POWEAL R, ROUNDING AND EOLCORPLAN DRAWINGS. <br />UNLESS OTHERWISE SPECIFIED. <br />9. <br />ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL <br />11. <br />THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY <br />NOT BE USED FOR GROUNDING CONNECTIONS. <br />SCIP ID: 17726-004-B <br />THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND <br />10. <br />THE SUBCONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, <br />12. <br />POWER AND CONTROL WIRING NOT IN TUBING OR CONDUIT SHALL BE <br />STABILIZED TO PREVENT EROSION AS SPECIFIED ON THE PROJECT SPECIFICATIONS. <br />LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT <br />MULTI -CONDUCTOR, TYPE TC CABLE (#14 AWG OR LARGER), 600 V, OIL RESISTANT <br />10. <br />USE OF 90° BENDS IN THE PROTECTION GROUNDING CONDUCTORS <br />SUBCONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. <br />SHALL BE AVOIDED WHEN 45° BENDS CAN BE ADEQUATELY SUPPORTED. <br />12. <br />SUBCONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. <br />THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90° C (WET AND <br />EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN <br />11. <br />SUBCONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH <br />DRY) OPERATION WITH OUTER JACKET LISTED OR LABELED FOR THE LOCATION USED <br />11. <br />EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING <br />ADDRESS: <br />CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL. <br />AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS <br />UNLESS OTHERWISE SPECIFIED. <br />CONNECTIONS BELOW GRADE. <br />4030 COLBY AVE <br />REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. <br />13. <br />NOTICE TO PROCEED- NO WORK TO COMMENCE PRIOR TO COMPANY'S WRITTEN NOTICE TO <br />13. <br />ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE, COMPRESSION <br />12. <br />ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) <br />EVERETT, WA 98201 <br />PROCEED AND THE ISSUANCE OF A PURCHASE ORDER. <br />12. <br />SUBCONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD <br />WIRE LUGS AND WIRE NUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRE <br />SHALL BE FORMED USING HIGH PRESS CRIMPS. <br />BE REMOVED FROM SITE ON A DAILY BASIS. <br />NUTS SHALL BE RATED FOR OPERATION AT NO LESS THAN 75° C (90° C IF <br />14. <br />ALL CONSTRUCTION MEANS AND METHODS; INCLUDING BUT NOT LIMITED TO, ERECTION <br />AVAILABLE). <br />13. <br />COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY <br />PLANS, RIGGING PLANS, CLIMBING PLANS, AND RESCUE PLANS SHALL BE THE <br />EXOTHERMIC WELD CONNECTIONS. <br />COUNTY: <br />RESPONSIBILITY OF THE GENERAL CONTRACTOR RESPONSIBLE FOR THE EXECUTION OF THE <br />14. <br />RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN <br />WORK CONTAINED HEREIN AND SHALL MEET ANSI/TIA 1019 (LATEST EDITION), OSHA, AND <br />ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND NEC. <br />14. <br />ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED <br />SNOHOMISH COUNTY <br />GENERAL INDUSTRY STANDARDS. ALL RIGGING PLANS SHALL ADHERE TO ANSI/TIA-1019 <br />OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR. <br />(LATEST EDITION) INCLUDING THE REQUIRED INVOLVEMENT OF A QUALIFIED ENGINEER FOR <br />15. <br />ELECTRICAL METALLIC TUBING (EMT) OR RIGID NONMETALLIC CONDUIT (I.E. RIGID PVC <br />CLASS IV CONSTRUCTION. <br />SCHEDULE 40 OR RIGID PVC SCHEDULE 80 FOR LOCATIONS SUBJECT TO PHYSICAL <br />15. <br />APPROVED ANTIOXIDANT COATINGS (I.E. CONDUCTIVE GEL OR PASTE) <br />DAMAGE) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. <br />SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND <br />CONNECTIONS. <br />16. <br />ELECTRICAL METALLIC TUBING (EMT), ELECTRICAL NONMETALLIC TUBING (ENT) OR RIGID <br />NONMETALLIC CONDUIT (RIGID PVC, SCHEDULE 40) SHALL BE USED FOR CONCEALED <br />16. <br />ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A <br />INDOOR LOCATIONS. <br />CORROSION RESISTANT MATERIAL. <br />17. <br />SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL <br />17. <br />MISCELLANEOUS ELECTRICAL AND NON -ELECTRICAL METAL BOXES, <br />ISSUED FOR' <br />STRUCTURAL STEEL NOTES: <br />ELBOWS/90s AND ALL APPROVED ABOVE GRADE PVC CONDUIT. <br />FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN <br />ACCORDANCE WITH THE NEC. <br />18. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED <br />18. BOND ALL METALLIC OBJECTS WITHIN 6 FT. OF MAIN GROUND WIRES <br />1. ALL STEEL WORK SHALL BE PAINTED IN ACCORDANCE WITH THE PROJECT <br />INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. <br />WITH 1 -#2 AWG TIN-PLATED COPPER GROUND CONDUCTOR. <br />SPECIFICATIONS AND IN ACCORDANCE WITH ASTM A36 UNLESS OTHERWISE NOTED. <br />2. BOLTED CONNECTIONS SHALL BE ASTM A325 BEARING TYPE (3/4" 0) CONNECTIONS AND <br />19. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION -TYPE AND <br />APPROVED FOR THE LOCATION USED. SET SCREW FITTINGS ARE NOT ACCEPTABLE. <br />19. GROUND CONDUCTORS USED IN THE FACILITY GROUND AND LIGHTNING <br />SHALL HAVE MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE. <br />PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC <br />20. CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN <br />OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS <br />3. NON-STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8" 0 ASTM A307 <br />ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND NEC. <br />METALLIC CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH <br />BOLTS UNLESS NOTED OTHERWISE. <br />WALLS OR FLOORS, WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT <br />TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC <br />21. WIREWAYS SHALL BE EPDXY -COATED (GRAY) AND INCLUDE A HINGED COVER, DESIGNED <br />MATERIAL SUCH AS PVC PLASTIC CONDUIT SHALL BE USED. WHERE <br />4. INSTALLATION OF CONCRETE EXPANSION/WEDGE ANCHOR, SHALL BE PER <br />TO SWING OPEN DOWNWARDS; SHALL BE PANDUIT TYPE E (OR EQUAL); AND RATED <br />USE OF METAL CONDUIT IS UNAVOIDABLE (E.G., NONMETALLIC CONDUIT <br />MANUFACTURER'S RECOMMENDED PROCEDURE. THE ANCHOR BOLT, DOWEL OR ROD <br />NEMA 1 (OR BETTER). <br />PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE <br />SHALL CONFORM TO MANUFACTURER'S RECOMMENDATION FOR EMBEDMENT DEPTH OR AS <br />BONDED TO EACH END OF THE METAL CONDUIT. <br />SHOWN ON THE DRAWINGS. NO REBAR SHALL BE CUT WITHOUT PRIOR CONTRACTOR <br />22. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON -PERFORATED <br />APPROVAL WHEN DRILLING HOLES IN CONCRETE. SPECIAL INSPECTIONS, REQUIRED BY <br />ABBREVIATIONS AND SYMBOLS: <br />STRAPS AND HANGERS. EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE <br />20. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE <br />GOVERNING CODES, SHALL BE PERFORMED IN ORDER TO MAINTAIN MANUFACTURER'S <br />ABBREVIATIONS: <br />WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN <br />MUST BE #2 TINNED SOLID IN 3/4" LIQUID TIGHT CONDUIT FROM 24" <br />MAXIMUM ALLOWABLE LOADS. <br />SYMBOLS: <br />CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. <br />BELOW GRADE TO WITHIN 3" TO 6" OF CAD TERMINATION POINT. <br />CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT <br />-WELD <br />AGL ABOVE GRADE LEVEL SOLID GROUND BUS BAR <br />OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. <br />THE EXPOSED END OF THE LIQUID TIGHT CONDUIT MUST BE SEALED <br />S <br />WITH SILICONE CAULK (ADD TRANSITIONING GROUND STANDARD DETAIL <br />REV <br />DATE <br />DRWN BY <br />DESCRIPTION <br />QA/QC <br />A <br />11/15/18 <br />SBP <br />PCD FOR REVIEW <br />CW <br />0 <br />04/10/19 <br />SBP <br />CONSTRUCTION SET <br />CW <br />1 <br />06/ 11 / 19 <br />SBP <br />CLIENT COMMENTS <br />CW <br />2 <br />07/19/19 <br />SBP <br />CLIENT COMMENTS <br />CW <br />3 <br />08/14/19 <br />SBP <br />CLIENT COMMENTS <br />CW <br />4 <br />11/20/19 <br />SBP <br />CLIENT COMMENTS <br />CW <br />5 <br />12/ 11 / 19 <br />SBP <br />CLIENT COMMENTS <br />CW <br />6 <br />03/18/20 <br />SBP <br />CLIENT COMMENTS <br />CW <br />7 <br />11/10/20 <br />JD <br />GENERAL, UPDATES <br />CW <br />8 <br />08/03/21 <br />JD <br />JDX COMMENTS <br />CW <br />9 <br />11/09/21 <br />JD <br />JDX COMMENTS <br />CW <br />tti�) <br />(E) <br />tsbt IKHNJI:tIVtK biAiiviv <br />EXISTING <br />� SOLID NEUTRAL BUS BAR <br />I'AKALLtL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. <br />SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL <br />ALL C:C7NUU11 <br />BE <br />••"" """""•` "^""•. �^"" "•^'"""""•"•" "'•""'•" "'^'""^'•" ""^" <br />AS WELL). <br />MIN. <br />MINIMUM <br />SUPPLEMENTAL GROUND CONDUCTOR <br />TEMPORARILY CAPPED FLUSH TO FINISH GRADE TO PREVENT CONCRETE, <br />PLASTER OR <br />REF <br />REFERENCE <br />DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES <br />BY <br />RF RADIO FREQUENCY � 2-POLE THERMAL -MAGNETIC CIRCUIT <br />GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON <br />CONCRETE AND REINFORCING STFFI NOTES: T.e.D. <br />to BE DETERMINED <br />BREAKER <br />LOCKNUT ON OUTSIDE AND INSIDE. <br />T.B.R. <br />TO BE RESOLVED <br />SINGLE -POLE THERMAL -MAGNETIC <br />TYP <br />TYPICAL <br />CIRCUIT BREAKER <br />23. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE <br />1. <br />ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318, ACI <br />REQ <br />REQUIRED <br />e <br />CHEMICAL GROUND ROD <br />GALVANIZED OR EPDXY -COATED SHEET STEEL; SHALL MEET OR EXCEED UL 50 AND <br />336, ASTM A184, ASTM A185 AND THE DESIGN AND CONSTRUCTION SPECIFICATION <br />EGR <br />EQUIPMENT GROUND RING <br />RATED NEMA 1 (OR BETTER) INDOORS OR NEMA 3R (OR BETTER) OUTDOORS. <br />FOR CAST -IN -PLACE CONCRETE. <br />AWG <br />AMERICAN WIRE GAUGE <br />® <br />TEST WELL <br />MGB <br />MASTER GROUND BAR <br />24. METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY -COATED <br />2. <br />ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT <br />EG <br />EQUIPMENT GROUND <br />�� <br />DISCONNECT SWITCH <br />OR NON -CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1; AND RATED <br />28 DAYS, UNLESS NOTED OTHERWISE. SLAB FOUNDATION DESIGN ASSUMING <br />BCW <br />BARE COPPER WIRESIAD <br />NEMA 1 (OR BETTER) INDOORS OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. <br />ALLOWABLE SOIL BEARING PRESSURE OF 2000 PSF. <br />SMART INTEGRATED ACCESS DEVICE <br />� <br />METER <br />GEN <br />GENERATOR <br />EXOTHERMIC WELD (CADWELD) <br />25. NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA <br />3. <br />REINFORCING STEEL SHALL CONFORM TO ASTM A615 GRADE 60 DEFORMED <br />IGR <br />INTERIOR GROUND RING (HALO) <br />(UNLESS OTHERWISE NOTED) <br />OS 2• AND RATED NEMA 1 (OR BETTER) INDOORS OR WEATHER PROTECTED (WP OR <br />UNLESS NOTED OTHERWISE. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 <br />RBS <br />RADIO BASE STATION <br />BETTER) OUTDOORS. <br />WELDED STEEL WIRE FABRIC UNLESS NOTED OTHERWISE. SPLICES SHALL BE CLASS <br />MECHANICAL CONNECTION <br />"B" AND ALL HOOKS SHALL BE STANDARD, UNO. <br />GROUNDING WIRE <br />26. THE SUBCONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE <br />CONTRACTOR BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. <br />4. <br />THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING <br />STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: <br />27. THE SUBCONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES <br />AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND <br />CONCRETE CAST AGAINST EARTH..................3 IN. <br />STANDARDS TO SAFEGUARD LIFE AND PROPERTY. <br />CONCRETE EXPOSED TO EARTH OR WEATHER: <br />#6 AND LARGER..................................2 IN. <br />28. INSTALL PLASTIC LABEL ON THE METER CENTER TO SHOW "AT&T". <br />#5 AND SMALLER & WWF...................1 1 /2 IN. <br />CONCRETE NOT EXPOSED TO EARTH OR WEATHER OR NOT CAST AGAINST THE <br />29. ALL CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE PULL CORD <br />GROUND: <br />INSTALLED. <br />SLAB AND WALLS................................3/4 IN. <br />BEAMS AND COLUMNS ........................1 1 /2 IN. <br />5. <br />A CHAMFER 3/4" SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, <br />UNLESS NOTED OTHERWISE. IN ACCORDANCE WITH ACI 301 SECTION 4.2.4. <br />NEC INSULATOR COLOR CODE <br />DESCRIPTION <br />PHASE/CODE LETTER <br />WIRE COLOR <br />240/ 120 10 <br />LEG 1 <br />BLACK <br />LEG 2 <br />RED <br />AC NEUTRAL <br />N <br />WHITE <br />GROUND (EGC) <br />G <br />GREEN <br />VDC POS <br />+ <br />RED -POLARITY MAR <br />AT TERMINATION <br />VDC NEG <br />- <br />*BLACK -POLARITY <br />MARK AT <br />TERMINATION <br />240V OR 208V, 30 <br />PHASE A <br />BLACK <br />PHASE B <br />RED(ORG. IF HI LEG) <br />PHASE C <br />BLUE <br />480V, 30 <br />PHASE A <br />BROWN <br />PHASE B <br />ORANGE <br />PHASE C <br />YELLOW <br />N, EXA <br />WAsy� F9 <br />co <br />57449 <br />FsSFG/STE �ONA� <br />u� <br />NNa/y%c� <br />SIGNED, 10 NOV2021 <br />EXPIRES, 3 FEB 2022 <br />IT IS A VIOLATION OF LAW FOR ANY PERSON, <br />UNLESS THEY ARE ACTING UNDER THE DIRECTION <br />OF A LICENSED PROFESSIONAL ENGINEER, <br />TO ALTER THIS DOCUMENT. <br />SHEET NUMBER: REVISION: <br />* SEE NEC 210.5(C)(1) AND (2) <br />