LUMEN OUTPUT:
<br />PER HOUR WITH A GUST FACTOR OF 1.3.
<br />JDX SPECS/REQUIREMENTS:
<br />CONTRACTOR TO REVIEW THE BELOW LISTED JURISDICTIONAL REQUIREMENTS AND ENSURE
<br />ALL CONSTRUCTION MEETINGS OR EXCEED THE JURISDICTIONAL REQUIREMENTS.
<br />EMQT & DRAWINGS:
<br />SHOP DRAWINGS FOR TRAFFIC SIGNAL AND LUMINAIRE POLES: WITHIN 20 DAYS
<br />FOLLOWING EXECUTION OF THE CONTRACT, OR APPROVAL OF ELECTRICAL SUBCONTRACTOR,
<br />THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR THE TRAFFIC SIGNAL AND
<br />LUMINAIRE POLES TO BE USED ON THE PROJECT. WITHIN 20 DAYS FOLLOWING APPROVAL
<br />OF THE SHOP DRAWINGS, THE CONTRACTOR SHALL SUBMIT A LETTER TO THE ENGINEER
<br />CERTIFYING THAT THE POLES HAVE BEEN ORDERED AND CERTIFYING THE MANUFACTURER'S
<br />PLANNED DELIVERY DATE.
<br />EQUIPMENT SUBMITTAL FOR TRAFFIC SIGNAL EQUIPMENT: WITHIN 20 DAYS FOLLOWING
<br />EXECUTION OF THE CONTRACT, THE CONTRACTOR SHALL SUBMIT 3 COPIES OF COMPLETE
<br />CATALOG DATA FOR THE FOLLOWING ITEMS:
<br />• LOAD SWITCHES
<br />• CONFLICT MONITOR
<br />• DETECTOR AMPLIFIERS
<br />• PREEMPTION EQUIPMENT
<br />• LOOP SEALANT
<br />• VEHICLE & PEDESTRIAN SIGNAL HEADS & HARDWARE
<br />• SERVICE CABINETS
<br />• TERMINAL CABINETS
<br />• SIGNAL CONTROLLERS AND SOFTWARE
<br />• VIDEO DETECTION SYSTEMS
<br />• FIBER DISTRIBUTION UNITS
<br />• FIBER SWITCHES
<br />• CCTV CAMERA SYSTEM
<br />• DETECTOR CABLE
<br />• DETECTOR LOOP WIRE
<br />INDUCTION LOOPS _ _ _ _ _ _ _ _ _ _ _ _
<br />ACTUAL ORDERING OF THE EQUIPMENT.
<br />FULL J I f\IIV i
<br />ALL CONDUIT SHOWN IN THE PLANS, PROPOSED AND EXISTING CONDUIT TO RECEIVE
<br />CONDUCTORS, AND CONDUIT INSTALLED FOR FUTURE USE, SHALL HAVE FLAT WOVEN
<br />POLYESTER TAPE INSTALLED AND SECURED AT EITHER END OF THE RUN. TAPE SHALL BE
<br />DETECTABLE, �/❑ MINIMUM WIDTH AND PRINTED WITH SEQUENTIAL FOOTAGE MARKINGS.
<br />PULL STRENGTH SHALL BE 900LBS MINIMUM.
<br />CONDUIT SEALING
<br />MECHANICAL PLUGS FOR CABINET CONDUIT SEALING SHALL BE ONE OF THE FOLLOWING:
<br />1. TYCO ELECTRONICS — TDUX
<br />2. JACKMOON — TRIPLEX DUCT PLUGS
<br />3. 0—Z GEDNEY — CONDUIT SEALING BUSHINGS
<br />THE MECHANICAL PLUG SHALL WITHSTAND A MINIMUM OF 5 PSI OF PRESSURE.
<br />RIGID METAL CONDUIT FITTINGS AND APPURTENANCES
<br />SECTION 9-29.1(2) IS SUPPLEMENTED WITH THE FOLLOWING:
<br />CONDUIT COATINGS
<br />ELECTROPLATED COUPLINGS ARE NOT ALLOWED.
<br />SURFACE MOUNTING CONDUIT ATTACHMENT COMPONENTS
<br />CHANNEL SUPPORTS AND ALL FASTENING HARDWARE COMPONENTS SHALL BE TYPE 304
<br />STAINLESS STEEL. CONDUIT CLAMPS SHALL BE ONE PIECE, TWO BOLT UNITS WITH LOCK
<br />WASHERS.
<br />NON—METALLIC CONDUIT
<br />SECTION 9-29.1(4) IS SUPPLEMENTED WITH THE FOLLOWING:
<br />PVC CONDUIT SHALL BE EITHER SCHEDULE 40 OR SCHEDULE 80, AS INDICATED ON THE
<br />PLANS. SCHEDULE 80 SHALL BE REQUIRED FOR ALL STREET CROSSINGS AND FOR THE
<br />BOTTOM 10' OF POLE RISERS. SCHEDULE 80 SHALL BE USED FOR ALL CONDUITS THAT
<br />ARE INSTALLED USING DIRECTIONAL BORE METHOD. BELL END BUSHINGS SHALL BE
<br />INSTALLED ON ALL CONDUIT ENDS. CONDUIT RUNS, WITHOUT INNERDUCT, INSTALLED
<br />USING DIRECTIONAL BORING METHOD SHALL BE SCHEDULE 80 HIGH DENSITY
<br />POLYETHYLENE (HDPE) IF THE RUNS ENTER/CROSS THE TRAVELED WAY OR SHOULDER,
<br />AND SCHEDULE 40 HPDE FOR RUNS THAT DO NOT ENTER OR CROSS THE TRAVELED WAY
<br />OR SHOULDER.
<br />LUMINAIRES:
<br />SECTION 8-20.3(13)C IS SUPPLEMENTED WITH THE FOLLOWING
<br />UNLESS OTHERWISE NOTED, LUMINAIRES IN THE PROJECT WILL BE FURNISHED AND
<br />INSTALLED BY THE CONTRACTOR.
<br />STREET LUMINAIRES (LED)
<br />STREET LUMINAIRES SHALL BE AN INTEGRAL UNIT WITH THE SPECIFIED OPTICAL
<br />PERFORMANCE, AND MECHANICAL FEATURES THAT FACILITATE INSTALLATION AND
<br />MAINTENANCE. THE FIXTURE SHALL HAVE A FULL SIZE TERMINAL BLOCK AND QUICK
<br />ELECTRICAL DISCONNECTS TO ASSURE EASY INSTALLATION, LEVELING, AND MAINTENANCE
<br />ACCESS. A FLUSH HOUSE —SIDE SHIELD PLATE SHALL BE FACTORY SUPPLIED AND
<br />INSTALLED IF REQUIRED BY THE PLANS.
<br />THE HOUSING SHALL BE CAST ALUMINUM WITH A UNIVERSAL 4 BOLT SLIPFITTER FOR A
<br />TWO INCH NOMINAL MOUNTING TENON. THE UNIT SHALL HAVE COOLING FINS TO MAKE
<br />FOR A LONG —LIFE, EFFICIENT LED UNIT. ELECTRICAL COMPONENTS SHALL BE ACCESSIBLE
<br />WITHOUT TOOLS AND MOUNTED ON OR BEHIND A REMOVABLE POWER DOOR. THE POWER
<br />DOOR SHALL FEATURE QUICK ELECTRICAL DISCONNECTS TO THE TERMINAL BOARD AND
<br />LED BOARD. THE LUMINAIRE SHALL BE PROVIDED WITH A ANSI SEVEN PIN (PCR7)
<br />PHOTOCELL RECEPTACLE.
<br />EACH LUMINAIRE SHALL BE PROVIDED WITH A LONG LIFE PHOTOCELL COMPATIBLE WITH
<br />THE SEVEN PIN (PCR7) RECEPTACLE. THE FOLLOWING PHOTOCELLS ARE PRE —APPROVED
<br />FOR USE:
<br />RIPLEY LIGHTING CONTROLS LONG LIFE II 6390LL—BK-2.8
<br />SUN —TECH TRS-2-8190
<br />DARK TO LIGHT DLL ELITE 127-2.8 IR
<br />THE LED NOMINAL CORRELATED COLOR TEMPERATURE SHALL BE 40000K +/— 2000K WITH
<br />A CRI >_ 70. THE LIGHT EMITTING DIODES SHALL BE HIGH FLUX, HIGH POWER WHITE LED
<br />PRODUCING A MINIMUM OF 90% OF INITIAL INTENSITY AT 70,000 HOURS OF LIFE. THE
<br />LEDS SHALL PROVIDE A COPY OF THEIR TEST DOCUMENTATION TO THE ENGINEER FOR
<br />THE IES LM-80 TESTING PROCEDURE. THE LEDS SHALL BE MERCURY AND LEAD FREE.
<br />NOMINAL LUMEN EFFICACY SHALL EXCEED 108 LUMENS/W.
<br />INDIVIDUAL MICRO —LENS OPTICS SHALL PRODUCE IES TYPE 2 OR TYPE 3 FULL CUTOFF
<br />DISTRIBUTIONS WITH 0% LUMENS ABOVE 900 NADIR. THE POWER SUPPLY SHALL HAVE
<br />LESS THAN 20% TOTAL HARMONIC DISTORTION AND A MINIMUM POWER FACTOR OF 0.90.
<br />THE EMC SHALL MEET OR EXCEED FCC CFR PART 15. TRANSIENT VOLTAGES SHALL
<br />COMPLY WITH ANSI C62.41 CAT. A. AN INTEGRAL SURGE PROTECTOR SHALL MEET
<br />ANSI/IEEE C62.45, C62.41.2, IEC61000-4-2, AND IEC 61000-4-4. EACH LUMINAIRE
<br />SHALL BE PROVIDED WITH A STANDARD 3" X 3" ANSI LABEL INDICATING THE WATTAGE AND
<br />THE LIGHT SOURCE TYPE (LED), USING BLACK LETTERS ON A REFLECTIVE WHITE
<br />BACKGROUND.
<br />THE FINISH SHALL BE A FADE AND ABRASION RESISTANT, EPDXY POLYESTER POWDER
<br />COAT WITH A LIGHT GRAY COLOR. THE LUMINAIRE SHALL MEET UL LISTING FOR WET
<br />LOCATIONS AND MAINTAIN AN IP66 RATING FOR THE OPTICS COMPARTMENT AND AN IP54
<br />RATING OR BETTER FOR THE POWER COMPARTMENT.
<br />SMALL LUMINAIRE (200W HPS RELATIVE EQUIVALENT):
<br />TYPE 2 OR TYPE 3 DISTRIBUTION: >_ 9,200 LUMENS
<br />MEDIUM LUMINAIRE (250W HPS RELATIVE EQUIVALENT):
<br />TYPE 2 OR TYPE 3 DISTRIBUTION: >_ 1 1,700 LUMENS
<br />LARGE LUMINAIRE (400W HPS RELATIVE EQUIVALENT):
<br />TYPE 2 OR TYPE 3 DISTRIBUTION: >_ 18,000 LUMENS
<br />THE FOLLOWING LISTED FIXTURES MEET THE REQUIRED SPECIFICATIONS:
<br />SMALL LUMINAIRE:
<br />TYPE 2 DISTRIBUTION:
<br />LEOTEK GCM 1-60J—MV-40K-2R—GY-095—PCR7-4B—RWG—WL—BSK
<br />SCHREDER SMART2—US-24L093—NW—T2M—SV—GY—D01—AA—AB
<br />LED ROADWAY NXT-48M-0-7-2LB-5—GY-3—UL—X-4H—BIRD
<br />TYPE 3 DISTRIBUTION:
<br />LEOTEK GCM 1-60J—MV-40K-3R—GY-095—PCR7-4B—RWG—WL—BSK
<br />SCHREDER SMART2—US-24L093—NW—T3M—SV—GY—D01—AA—AB
<br />LED ROADWAY NXT-48M-0-7-3LB-5—GY-3—UL—X-4H—BIRD
<br />MEDIUM LUMINAIRE:
<br />TYPE 2 DISTRIBUTION:
<br />LEOTEK GCM1-60J—MV-40K-2R—GY-125—PCR7-4B—RWG—WL—BSK
<br />SCHREDER SMART2—US-36L134—NW—T2M—SV—GY—D0I—AA—AB
<br />LED ROADWAY NXT-60M-0-7-2LB-5—GY-3—UL—X-4H—BIRD
<br />TYPE 3 DISTRIBUTION:
<br />LEOTEK GCM 1-60J—MV-40K-3R—GY-125—PCR7-4B—RWG—WL—BSK
<br />SCHREDER SMART2—US-361_134—NW—T3M—SV—GY—D01—AA—AB
<br />LED ROADWAY NXT-60M-0-7-3LB-5—GY-3—UL—X-4H—BIRD
<br />LARGE LUMINAIRE:
<br />TYPE 2 DISTRIBUTION:
<br />LEOTEK GCM3-60J—MV-40K-2R—GY-185—PCR7-4B—RWG—WL—BSK
<br />SCHREDER SMART3—US-48L185—NW—T2M—SV—GY—D01—AA—AB
<br />LED ROADWAY NXT-72M-0-7-2LB-7—GY-3—UL—X-4H—BIRD
<br />TYPE 3 DISTRIBUTION:
<br />LEOTEK GCM3-60J—MV-40K-3R—GY— 1 85—PCR7-4B—RWG—WL—BSK
<br />SCHREDER SMART3—US-481_185—NW—T3M—SV—GY—D01—AA—AB
<br />LED ROADWAY NXT-72M-0-7-3LB-7—GY-3—UL—X-4H—BIRD
<br />LUMINAIRES
<br />SECTION 9-29.10 IS SUPPLEMENTED WITH THE FOLLOWING:
<br />THE CONTRACTOR SHALL INSTALL THE POLE AND BRACKET CABLE TO THE END OF THE
<br />LUMINAIRE ARM WITH THIRTY (30) INCHES OF EXCESS WIRE TO HOOK UP THE LUMINAIRE.
<br />CONVENTIONAL ROADWAY LUMINAIRES
<br />SECTION 9-29.10(1) IS SUPPLEMENTED WITH THE FOLLOWING:
<br />THE CONTRACTOR SHALL CHOMLVU TI fMKLSW Em FWMLrFACTOSELI�\IM
<br />SPECIFICATIONS: SERIES SMARTLUMETM ROADWAYTM
<br />LUMINAIRE SMART2—US SERIES NXTTM
<br />MANUFACTURER LEOTEK TM LAMP 24L OR 36L LUMINAIRE NXT—M
<br />SERIES GREEN COBRA TM COLOR TEMP 4000°K LAMP 60M
<br />LUMINAIRE GCA1 OPTICAL SYSTEM 2 OR 3 COLOR TEMP 4500°K
<br />LAMP 60F OR 80F LED OR VOLTAGE 120-277V OR OPTICAL SYSTEM 3LB
<br />COLOR TEMP 4300°K FINISH GY (GREY) VOLTAGE 120-277V
<br />OPTICAL SYSTEM 2 OR 3 FINISH GY (GREY)
<br />VOLTAGE 120-277V
<br />FINISH GY (GREY)
<br />COVER MARKINGS:
<br />SECTION 9-29.2(4) IS SUPPLEMENTED WITH THE FOLLOWING:
<br />JUNCTION BOX IDENTIFICATION
<br />JUNCTION BOXES, PULL BOXES AND CABLE VAULTS SHALL BE MARKED WITH THE
<br />APPROPRIATE LEGEND IN ACCORDANCE WITH THE BEAD WELD DETAILS IN THE STANDARD
<br />PLANS AND PER 9-29.2(4). JUNCTION BOXES, PULL BOXES AND CABLE VAULTS
<br />CONTAINING ONLY TRAFFIC SIGNAL INTERCONNECT (FIBER OPTIC OR TWISTED PAIR) CABLE
<br />SHALL BE MARKED OR EMBOSSED WITH THE LEGEND "COMM".
<br />JUNCTION BOXES:
<br />SECTION 9-29.2 IS SUPPLEMENTED WITH THE FOLLOWING:
<br />ALL JUNCTION BOXES SHALL CONFORM TO THE DETAILS SHOWN ON THE WSDOT STANDARD
<br />DRAWINGS J-40 SERIES, CITY OF EVERETT STANDARD DRAWING 805, AND SHALL BE OF
<br />THE TYPE INDICATED IN THE PLANS. ALL JUNCTION BOX LIDS AND FRAMES SHALL BE
<br />GALVANIZED AND THOSE INSTALLED WITHIN SIDEWALK AREAS SHALL BE SLIP —RESISTANT.
<br />ALL JUNCTION BOXES SHALL HAVE BASE SECTIONS AS SHOWN IN CITY OF EVERETT
<br />STANDARD DRAWING 805. ALL JUNCTION BOXES TO BE LOCATED IN THE STREET OR
<br />SHOULDER AREA SHALL BE HEAVY DUTY JUNCTION BOXES AS DETAILED IN STANDARD
<br />PLAN 1-40.20 AND DESCRIBED IN SECTION 9-29.2(1)B.
<br />VAULTS SHALL BE AS INDICATED ON THE DRAWINGS SHALL BE 233—LA, 444—LA AND
<br />504—LA, OR APPROVED EQUIVALENT. LIDS FOR THE VAULTS SHALL BE 23-2436P,
<br />44-332P AND 55-332P, RESPECTIVELY AND SHALL BE SLIP —RESISTANT.
<br />ALL JUNCTION BOXES AND VAULTS PLACED IN SIDEWALK OR PEDESTRIAN PATH SHALL
<br />MEET A GAP ACCEPTANCE REQUIREMENT OF NO MORE THAN %" WIDE WITH GREATER THAN
<br />�/" DEEP DEPRESSION. ANY JUNCTION BOXES OR VAULTS THAT DO NOT MEET THE GAP
<br />ACCEPTANCE REQUIREMENT WILL BE REJECTED.
<br />CONCRETE JUNCTION BOXES
<br />SLIP —RESISTANT TREATMENT ON VAULTS, SLIP —RESISTANT LID, AND SLIP —RESISTANT FRAME
<br />SHALL BE TREATED WITH MEBAC#1 AS MANUFACTURED BY IKG INDUSTRIES, OR SLIPNOT
<br />GRADE 3—COARSE AS MANUFACTURED BY W.S. MOLNAR CO, OR SAFTRAX TH604 BY
<br />THERMION, INC. WHERE THE EXPOSED PORTION OF THE FRAME IS 1/2 INCH WIDE OR
<br />LESS THE SLIP —RESISTANT TREATMENT MAY BE OMITTED ON THAT PORTION OF THE
<br />FRAME. THE SLIP —RESISTANT LID SHALL BE IDENTIFIED WITH PERMANENT MARKING ON THE
<br />UNDERSIDE INDICATING THE TYPE OF SURFACE TREATMENT ("M1" FOR MEBAC#1; OR "S3"
<br />FOR SLIPNOT GRADE 3—COARSE, OR TH FOR THERMION) AND THE YEAR MANUFACTURED.
<br />THE PERMANENT MARKING SHALL BE 1/8 INCH LINE THICKNESS FORMED WITH A MILD
<br />STEEL WELD BEAD.
<br />LIGHT STANDARDS:
<br />SECTION 9-29.6 IS SUPPLEMENTED WITH THE FOLLOWING:
<br />LIGHT STANDARDS OR SIGNAL STANDARDS MAY BE PAINTED OR FINISHED AS IDENTIFIED IN
<br />THE PLANS AND SPECIFICATIONS.
<br />ALL LIGHTING STANDARDS FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE
<br />ALUMINUM, GALVANIZED STEEL, OR CONCRETE AS SPECIFIED ON THE PLANS. UNLESS
<br />OTHERWISE NOTED ON THE PLANS, ALUMINUM AND STEEL STANDARDS SHALL HAVE LARGE
<br />RADIUS DAVIT LUMINAIRE ARMS. MOUNTING HEIGHTS FOR LIGHT FIXTURES SHALL BE 35'
<br />UNLESS OTHERWISE INDICATED ON THE PLANS. THE BASE SHALL HAVE 4 ANCHOR BOLTS
<br />WITH A NOMINAL 1 1-12" BOLT CIRCLE OR PER THE POLE FABRICATOR'S STANDARDS FOR
<br />THE PARTICULAR POLE.
<br />ALL POLES AND ARMS SHALL BE DESIGNED WITH A MINIMUM WEIGHT OF 50 POUNDS FOR
<br />THE LUMINAIRE AND TO WITHSTAND PRESSURES CAUSED BY WIND LOADS OF 90 MILES
<br />ALL POLES TO BE FURNISHED SHALL MAINTAIN A MINIMUM SAFETY FACTOR ON YIELD
<br />STRENGTH AND BASIC WIND PRESSURE PER THE AASHTO RECOMMENDATIONS FOR THE
<br />PARTICULAR POLE MATERIAL.
<br />THE SHAFTS SHALL BE PROVIDED WITH A 4" X 6" (MINIMUM DIMENSION) FLUSH
<br />HANDHOLE NEAR THE BASE DESIGNED TO PREVENT LOSS OF SHAFT STRENGTH AND
<br />PROVIDED WITH MATCHING METAL COVERS SECURED WITH STAINLESS STEEL SCREWS OR
<br />BOLTS. THE HANDHOLES SHALL BE LOCATED NEAR THE BASE AND ON THE DOWN
<br />STREAM SIDE OF TRAFFIC FLOW. A GROUNDING NUT OR PROVISION IN THE HANDHOLE
<br />FRAME FOR ACCOMMODATING A THREADED BOLT FOR THE PURPOSE OF ATTACHING
<br />GROUNDING CONNECTOR SHALL BE PROVIDED ON THE INSIDE OF THE SHAFT.
<br />ALL STREET LIGHTING POLE SHAFTS SHALL BE ROUND AND TAPERED UNLESS OTHERWISE
<br />NOTED ON THE PLANS OR APPROVED BY THE ENGINEER. MATERIAL FOR ALUMINUM
<br />POLES SHALL BE NATURAL POLISHED ALUMINUM.
<br />ALL BOLTS, NUTS, SCREWS, AND WASHERS, BUT NOT INCLUDING ANCHOR BOLTS AND
<br />UNLESS OTHERWISE SPECIFICALLY DESIGNATED HEREIN, SHALL BE STAINLESS STEEL.
<br />THE LUMINAIRE ARMS SHALL HAVE A NOMINAL LENGTH AS SHOWN ON THE PLANS
<br />MEASURED FROM THE CENTERLINE OF THE SHAFT. THE OUTER PORTION OF THE ARM
<br />SHALL BE NEARLY HORIZONTAL TO PLUS 50 ABOVE HORIZONTAL AND SHALL BE
<br />FURNISHED WITH A 1-1/2" TO 2" O.D. TENON WITH A MAXIMUM LENGTH OF 10" TO FIT
<br />THE LUMINAIRES SPECIFIED HEREIN.
<br />FOUNDATIONS FOR STREET LIGHTS SHALL BE IN ACCORDANCE WITH CITY OF EVERETT
<br />STANDARD PLAN 812.
<br />COMPLETE CALCULATIONS FOR STRUCTURAL DESIGN SHALL BE SUBMITTED WITH THE SHOP
<br />DRAWINGS FOR APPROVAL BEFORE FABRICATION OR ORDERING MATERIAL. THESE
<br />CALCULATIONS SHALL INCLUDE THE STRESSES IN THE POLE AND MAST ARMS, THE
<br />DEFLECTIONS AT THE FREE END OF THE MAST ARM, THE ATTACHMENT OF THE LUMINAIRES
<br />TO THE STRUCTURE, THE CONNECTION BETWEEN THE MAST ARMS AND VERTICAL POLE,
<br />POLE SECTION AT HANDHOLES, BASE PLATE, ANCHOR BOLTS, AND FOUNDATION. THE
<br />SUBMITTAL SHALL INCLUDE THE MATERIAL SPECIFICATIONS AND DETAILS OF THE
<br />FOUNDATION AND ANCHOR BOLTS.
<br />9-29.6(5) FOUNDATION HARDWARE
<br />THE FIRST PARAGRAPH OF SECTION 9-29.6(5) IS REVISED TO READ:
<br />ANCHOR BOLTS FOR TYPE PPB, PS, I, FB, AND RM SIGNAL STANDARDS SHALL CONFORM
<br />TO THE REQUIREMENTS OF ASTM F1554, GRADE 55. NUTS SHALL MEET THE
<br />REQUIREMENTS OF AASHTO M 291, GRADE A. WASHERS SHALL MEET THE REQUIREMENTS
<br />OF ASTM F 844 OR ASTM F 436
<br />ELECTIRICAL SPLICE MATERIALS:
<br />FUSED QUICK —DISCONNECT KITS
<br />SECTION 9-29.7(2) IS SUPPLEMENTED WITH THE FOLLOWING:
<br />SOLDERED COMPRESSION CONNECTIONS ARE NOT ALLOWED. ILLUMINATION FUSED QUICK
<br />DISCONNECTS SHALL BE TYPE 65U, SINGLE DISCONNECT PER CONDUCTOR.
<br />CONTRACTING AGENCY OWED EQUIPMENT:
<br />SECTION 8-20.3(1) IS SUPPLEMENTED WITH THE FOLLOWING:
<br />CONTRACTING AGENCY OWNED EQUIPMENT
<br />A PORTION OF THE TEMPORARY OR EXISTING ELECTRICAL EQUIPMENT TO BE REMOVED
<br />SHALL REMAIN THE PROPERTY OF THE CONTRACTING AGENCY.
<br />WHERE CALLED FOR IN THE PLANS, THE FOLLOWING SHALL BE DISCONNECTED,
<br />DISMANTLED, AND DELIVERED TO THE CONTRACTING AGENCY:
<br />• TRAFFIC SIGNAL CONTROLLER CABINETS, AND ALL AUXILIARY EQUIPMENT AND ETHERNET
<br />SWITCHES IN ALL TRAFFIC SIGNAL CABINETS.
<br />SIGNAL DISPLAYS AND PEDESTRIAN DISPLAYS WHICH REMAIN THE PROPERTY OF THE
<br />CONTRACTING AGENCY SHALL BE DELIVERED TO:
<br />CITY OF EVERETT POLE YARD
<br />4015 RAILWAY AVE.
<br />EVERETT, WA 98201
<br />PHONE: (425) 257-7296
<br />ALL OTHER REMOVED ELECTRICAL EQUIPMENT WHICH REMAINS THE PROPERTY OF THE
<br />CONTRACTING AGENCY SHALL BE DELIVERED TO:
<br />CITY OF EVERETT SIGNAL SHOP
<br />3200 CEDAR ST.
<br />EVERETT, WA 98201
<br />PHONE: (425) 257-7296
<br />FIVE DAYS WRITTEN ADVANCE NOTICE SHALL BE DELIVERED TO THE ENGINEER. DELIVERY
<br />SHALL OCCUR DURING THE HOURS OF 8:00 A.M. TO 2:00 P.M. MONDAY THROUGH FRIDAY.
<br />EQUIPMENT DAMAGED DURING REMOVAL OR DELIVERY SHALL BE REPAIRED OR REPLACED
<br />TO THE ENGINEER'S SATISFACTION AT NO COST TO THE CONTRACTING AGENCY.
<br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR UNLOADING THE EQUIPMENT WHERE
<br />DIRECTED BY THE ENGINEER AT THE DELIVERY SITE.
<br />CONTRACTOR OWNED REMOVALS
<br />ALL REMOVALS ASSOCIATED WITH AN ELECTRICAL SYSTEM, WHICH ARE NOT DESIGNATED TO
<br />REMAIN THE PROPERTY OF THE CONTRACTING AGENCY, SHALL BECOME THE PROPERTY OF
<br />THE CONTRACTOR AND SHALL BE REMOVED FROM THE PROJECT. ALL CONCRETE SIGNAL
<br />POLES, LUMINAIRES, AND OTHER EQUIPMENT NOT LISTED ABOVE SHALL BE THE PROPERTY
<br />OF THE CONTRACTOR AND REMOVED FROM THE PROJECT.
<br />THE CONTRACTOR SHALL:
<br />REMOVE ALL WIRES FOR DISCONTINUED CIRCUITS FROM THE CONDUIT SYSTEM.
<br />REMOVE ELBOW SECTIONS OF ABANDONED CONDUIT ENTERING JUNCTION BOXES.
<br />ABANDONED CONDUIT ENCOUNTERED DURING EXCAVATION SHALL BE REMOVED TO THE
<br />NEAREST OUTLETS OR AS DIRECTED BY THE ENGINEER.
<br />REMOVE FOUNDATIONS ENTIRELY, UNLESS THE PLANS STATE OTHERWISE.
<br />BACKFILL VOIDS CREATED BY REMOVAL OF FOUNDATIONS AND JUNCTION BOXES.
<br />BACKFILLING AND COMPACTION SHALL BE PERFORMED IN ACCORDANCE WITH SECTION
<br />2-09.3(1)E.
<br />ADJUST JUNCTION BOX:
<br />SECTION 8-20.3(6) IS SUPPLEMENTED WITH THE FOLLOWING:
<br />STANDARD DUTY PULL BOXES, CABLE VAULTS AND CONCRETE JUNCTION BOXES INSTALLED
<br />IN SIDEWALKS, WALKWAYS AND SHARED USE PATHS SHALL HAVE SLIP RESISTANT
<br />SURFACES, BE FLUSH WITH SURFACE AND MATCH GRADE OF THE SIDEWALK, WALKWAY
<br />AND SHARED USE PATH. THE BOXES, VAULTS AND JUNCTION BOXES SHALL NOT BE
<br />PLACED IN CURB RAMPS, CURB RAMP LANDINGS, OR THE GUTTER AREAS ASSOCIATED
<br />WITH THE CURB RAMPS. STANDARD DUTY NON —CONCRETE JUNCTION BOXES SHALL NOT
<br />BE INSTALLED IN SIDEWALKS, WALKWAYS OR SHARED USE PATHS.
<br />THE CONTRACTOR SHALL ADJUST EXISTING JUNCTION BOX TO NEW GRADE BY ADJUSTING
<br />GRAVEL PAD, IN ACCORDANCE TO WSDOT STANDARD DRAWINGS J-40 SERIES AND SHALL
<br />BE OF THE TYPE INDICATED IN THE PLANS. THE ADJUSTMENT OPERATIONS SHALL BE
<br />CONDUCTED TO PREVENT DAMAGE TO ANY CONDUITS. ALL PARTS OR MATERIALS DAMAGED
<br />AS A RESULT OF THE CONTRACTOR'S OPERATIONS SHALL BE REPLACED AT NO EXPENSE
<br />TO THE CONTRACTING AGENCY.
<br />IF THE JUNCTION BOX IS REMOVED AND RESET, THE PATCH MATERIAL USED AROUND THE
<br />JUNCTION BOX SHALL BE THE SAME AS THE ADJACENT PAVEMENT. FOR ASPHALT
<br />CONCRETE PAVEMENT ROADWAYS, JUNCTION BOXES LOCATED IN THE TRAVELED WAY SHALL
<br />BE ADJUSTED TO FINAL GRADE AFTER FINAL PAVING IN ACCORDANCE WITH SECTION
<br />5-04.3(13). FOR PORTLAND CEMENT CONCRETE PAVEMENT ROADWAYS, VALVE BOXES
<br />SHALL BE ADJUSTED PRIOR TO THE SURFACE FINISH.
<br />ALL JUNCTION BOXES AND VAULTS PLACED IN SIDEWALK OR PEDESTRIAN PATH SHALL
<br />MEET A GAP ACCEPTANCE REQUIREMENT OF NO MORE THAN �/2❑ WIDE WITH GREATER THAN
<br />1/❑ DEEP DEPRESSION. ANY JUNCTION BOXES OR VAULTS THAT DO NOT MEET THE GAP
<br />ACCEPTANCE REQUIREMENT WILL BE REJECTED.
<br />ALL JUNCTION BOXES AND VAULTS INSTALLED IN SIDEWALK AREAS SHALL HAVE NON—SKID
<br />COVERS. BOTH THE SLIP —RESISTANT LID AND SLIP —RESISTANT FRAME SHALL BE TREATED
<br />WITH MEBAC#1 AS MANUFACTURED BY IKG INDUSTRIES, OR SLIPNOT GRADE 3—COARSE AS
<br />MANUFACTURED BY W.S. MOLNAR CO, OR SAFTRAX TH604 BY THERMION, INC. WHERE THE
<br />EXPOSED PORTION OF THE FRAME IS �h INCH WIDE OR LESS THE SLIP —RESISTANT
<br />TREATMENT MAY BE OMITTED ON THAT PORTION OF THE FRAME. THE SLIP —RESISTANT LID
<br />SHALL BE IDENTIFIED WITH PERMANENT MARKING ON THE UNDERSIDE INDICATING THE TYPE
<br />OF SURFACE TREATMENT (❑M 1 ❑ FOR MEBAC#1 ; OR 11S311FOR SLIPNOT GRADE 3—COARSE,
<br />OR TH FOR THERMION) AND THE YEAR MANUFACTURED. THE PERMANENT MARKING SHALL
<br />BE 1/8 INCH LINE THICKNESS FORMED WITH A MILD STEEL WELD BEAD.
<br />CABLE RACKING IN PULL BOXES AND CABLE VAULTS
<br />THE CONTRACTOR SHALL RACK THE CABLE IN VERTICAL FIGURE EIGHT LOOPS, WHICH
<br />SHALL PERMIT PULLING SLACK FROM THE VAULTS WITHOUT INTRODUCING TWIST TO THE
<br />CABLE.
<br />CABLES SHALL BE SECURED IN RACKED POSITIONS WITH NYLON TIES. IDENTIFICATION OR
<br />WARNING TAGS SHALL BE SECURELY ATTACHED TO THE CABLES IN AT LEAST TWO
<br />LOCATIONS IN EACH PULL BOX OR CABLE VAULT.
<br />ALL COILED CABLE SHALL BE PROTECTED TO PREVENT DAMAGE TO THE CABLE AND
<br />FIBERS. RACKING SHALL INCLUDE SECURING CABLES TO BRACKETS (RACKING HARDWARE)
<br />THAT EXTEND FROM THE SIDE WALLS OF THE PULL BOX.
<br />ALL RACKING HARDWARE SHALL BE STAINLESS STEEL.
<br />at&t
<br />Mobility
<br />Network Solutions
<br />i ` `
<br />lr"f-PASTRUCTUP.E SEPVICES
<br />2227 W PECOS RD, SUITE 4
<br />CHANDLER, AZ 85224
<br />WAEVT-004-B
<br />SCIP ID: 17726-004-B
<br />ADDRESS:
<br />4030 COLBY AVE
<br />EVERETT, WA 98201
<br />COUNTY:
<br />SNOHOMISH COUNTY
<br />10411v-
<br />TCCTTL'Tl L,l1D.
<br />Z V V V Li! i V �_•
<br />REV
<br />DATE
<br />1
<br />DRWN B
<br />DESCRIPTION
<br />QA/QC
<br />A
<br />11 / 15/ 18
<br />SBP
<br />PCD FOR REVIEW
<br />CW
<br />0
<br />04/10/19
<br />SBP
<br />CONSTRUCTION SET
<br />CW
<br />1
<br />06/ 11 / 19
<br />SBP
<br />CLIENT COMMENTS
<br />CW
<br />2
<br />07/19/19
<br />SBP
<br />CLIENT COMMENTS
<br />CW
<br />3
<br />08/14/19
<br />SBP
<br />CLIENT COMMENTS
<br />CW
<br />4
<br />1 11/20/19
<br />SBP
<br />CLIENT COMMENTS
<br />CW
<br />5
<br />12/ 11 / 19
<br />SBP
<br />CLIENT COMMENTS
<br />CW
<br />6
<br />03/18/20
<br />SBP
<br />CLIENT COMMENTS
<br />CW
<br />7
<br />11/10/20
<br />JD
<br />GENERAL, UPDATES
<br />CW
<br />8
<br />08/03/21
<br />JD
<br />JDX COMMENTS
<br />CW
<br />9
<br />11/09/21
<br />JD
<br />JDX COMMENTS
<br />CW
<br />N, EXA
<br />WAsy� F9
<br />C-0� �z
<br />57449
<br />FsSFG/s7f_
<br />�ONAL�
<br />NNa/y%c�
<br />SIGNED, 10 NOV2021
<br />EXPIRES, 3 FEB 2022
<br />IT IS A VIOLATION OF LAW FOR ANY PERSON,
<br />UNLESS THEY ARE ACTING UNDER THE DIRECTION
<br />OF A LICENSED PROFESSIONAL ENGINEER,
<br />TO ALTER THIS DOCUMENT.
<br />SHEET NUMBER:
<br />T 3
<br />'ISION:
<br />9
<br />THE STREET LUMINAIRES SHALL MEET OR EXCEED THE FOLLOWING INITIAL DELIVERED
<br />
|