LUMEN OUTPUT: <br />PER HOUR WITH A GUST FACTOR OF 1.3. <br />JDX SPECS/REQUIREMENTS: <br />CONTRACTOR TO REVIEW THE BELOW LISTED JURISDICTIONAL REQUIREMENTS AND ENSURE <br />ALL CONSTRUCTION MEETINGS OR EXCEED THE JURISDICTIONAL REQUIREMENTS. <br />EMQT & DRAWINGS: <br />SHOP DRAWINGS FOR TRAFFIC SIGNAL AND LUMINAIRE POLES: WITHIN 20 DAYS <br />FOLLOWING EXECUTION OF THE CONTRACT, OR APPROVAL OF ELECTRICAL SUBCONTRACTOR, <br />THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR THE TRAFFIC SIGNAL AND <br />LUMINAIRE POLES TO BE USED ON THE PROJECT. WITHIN 20 DAYS FOLLOWING APPROVAL <br />OF THE SHOP DRAWINGS, THE CONTRACTOR SHALL SUBMIT A LETTER TO THE ENGINEER <br />CERTIFYING THAT THE POLES HAVE BEEN ORDERED AND CERTIFYING THE MANUFACTURER'S <br />PLANNED DELIVERY DATE. <br />EQUIPMENT SUBMITTAL FOR TRAFFIC SIGNAL EQUIPMENT: WITHIN 20 DAYS FOLLOWING <br />EXECUTION OF THE CONTRACT, THE CONTRACTOR SHALL SUBMIT 3 COPIES OF COMPLETE <br />CATALOG DATA FOR THE FOLLOWING ITEMS: <br />• LOAD SWITCHES <br />• CONFLICT MONITOR <br />• DETECTOR AMPLIFIERS <br />• PREEMPTION EQUIPMENT <br />• LOOP SEALANT <br />• VEHICLE & PEDESTRIAN SIGNAL HEADS & HARDWARE <br />• SERVICE CABINETS <br />• TERMINAL CABINETS <br />• SIGNAL CONTROLLERS AND SOFTWARE <br />• VIDEO DETECTION SYSTEMS <br />• FIBER DISTRIBUTION UNITS <br />• FIBER SWITCHES <br />• CCTV CAMERA SYSTEM <br />• DETECTOR CABLE <br />• DETECTOR LOOP WIRE <br />INDUCTION LOOPS _ _ _ _ _ _ _ _ _ _ _ _ <br />ACTUAL ORDERING OF THE EQUIPMENT. <br />FULL J I f\IIV i <br />ALL CONDUIT SHOWN IN THE PLANS, PROPOSED AND EXISTING CONDUIT TO RECEIVE <br />CONDUCTORS, AND CONDUIT INSTALLED FOR FUTURE USE, SHALL HAVE FLAT WOVEN <br />POLYESTER TAPE INSTALLED AND SECURED AT EITHER END OF THE RUN. TAPE SHALL BE <br />DETECTABLE, �/❑ MINIMUM WIDTH AND PRINTED WITH SEQUENTIAL FOOTAGE MARKINGS. <br />PULL STRENGTH SHALL BE 900LBS MINIMUM. <br />CONDUIT SEALING <br />MECHANICAL PLUGS FOR CABINET CONDUIT SEALING SHALL BE ONE OF THE FOLLOWING: <br />1. TYCO ELECTRONICS — TDUX <br />2. JACKMOON — TRIPLEX DUCT PLUGS <br />3. 0—Z GEDNEY — CONDUIT SEALING BUSHINGS <br />THE MECHANICAL PLUG SHALL WITHSTAND A MINIMUM OF 5 PSI OF PRESSURE. <br />RIGID METAL CONDUIT FITTINGS AND APPURTENANCES <br />SECTION 9-29.1(2) IS SUPPLEMENTED WITH THE FOLLOWING: <br />CONDUIT COATINGS <br />ELECTROPLATED COUPLINGS ARE NOT ALLOWED. <br />SURFACE MOUNTING CONDUIT ATTACHMENT COMPONENTS <br />CHANNEL SUPPORTS AND ALL FASTENING HARDWARE COMPONENTS SHALL BE TYPE 304 <br />STAINLESS STEEL. CONDUIT CLAMPS SHALL BE ONE PIECE, TWO BOLT UNITS WITH LOCK <br />WASHERS. <br />NON—METALLIC CONDUIT <br />SECTION 9-29.1(4) IS SUPPLEMENTED WITH THE FOLLOWING: <br />PVC CONDUIT SHALL BE EITHER SCHEDULE 40 OR SCHEDULE 80, AS INDICATED ON THE <br />PLANS. SCHEDULE 80 SHALL BE REQUIRED FOR ALL STREET CROSSINGS AND FOR THE <br />BOTTOM 10' OF POLE RISERS. SCHEDULE 80 SHALL BE USED FOR ALL CONDUITS THAT <br />ARE INSTALLED USING DIRECTIONAL BORE METHOD. BELL END BUSHINGS SHALL BE <br />INSTALLED ON ALL CONDUIT ENDS. CONDUIT RUNS, WITHOUT INNERDUCT, INSTALLED <br />USING DIRECTIONAL BORING METHOD SHALL BE SCHEDULE 80 HIGH DENSITY <br />POLYETHYLENE (HDPE) IF THE RUNS ENTER/CROSS THE TRAVELED WAY OR SHOULDER, <br />AND SCHEDULE 40 HPDE FOR RUNS THAT DO NOT ENTER OR CROSS THE TRAVELED WAY <br />OR SHOULDER. <br />LUMINAIRES: <br />SECTION 8-20.3(13)C IS SUPPLEMENTED WITH THE FOLLOWING <br />UNLESS OTHERWISE NOTED, LUMINAIRES IN THE PROJECT WILL BE FURNISHED AND <br />INSTALLED BY THE CONTRACTOR. <br />STREET LUMINAIRES (LED) <br />STREET LUMINAIRES SHALL BE AN INTEGRAL UNIT WITH THE SPECIFIED OPTICAL <br />PERFORMANCE, AND MECHANICAL FEATURES THAT FACILITATE INSTALLATION AND <br />MAINTENANCE. THE FIXTURE SHALL HAVE A FULL SIZE TERMINAL BLOCK AND QUICK <br />ELECTRICAL DISCONNECTS TO ASSURE EASY INSTALLATION, LEVELING, AND MAINTENANCE <br />ACCESS. A FLUSH HOUSE —SIDE SHIELD PLATE SHALL BE FACTORY SUPPLIED AND <br />INSTALLED IF REQUIRED BY THE PLANS. <br />THE HOUSING SHALL BE CAST ALUMINUM WITH A UNIVERSAL 4 BOLT SLIPFITTER FOR A <br />TWO INCH NOMINAL MOUNTING TENON. THE UNIT SHALL HAVE COOLING FINS TO MAKE <br />FOR A LONG —LIFE, EFFICIENT LED UNIT. ELECTRICAL COMPONENTS SHALL BE ACCESSIBLE <br />WITHOUT TOOLS AND MOUNTED ON OR BEHIND A REMOVABLE POWER DOOR. THE POWER <br />DOOR SHALL FEATURE QUICK ELECTRICAL DISCONNECTS TO THE TERMINAL BOARD AND <br />LED BOARD. THE LUMINAIRE SHALL BE PROVIDED WITH A ANSI SEVEN PIN (PCR7) <br />PHOTOCELL RECEPTACLE. <br />EACH LUMINAIRE SHALL BE PROVIDED WITH A LONG LIFE PHOTOCELL COMPATIBLE WITH <br />THE SEVEN PIN (PCR7) RECEPTACLE. THE FOLLOWING PHOTOCELLS ARE PRE —APPROVED <br />FOR USE: <br />RIPLEY LIGHTING CONTROLS LONG LIFE II 6390LL—BK-2.8 <br />SUN —TECH TRS-2-8190 <br />DARK TO LIGHT DLL ELITE 127-2.8 IR <br />THE LED NOMINAL CORRELATED COLOR TEMPERATURE SHALL BE 40000K +/— 2000K WITH <br />A CRI >_ 70. THE LIGHT EMITTING DIODES SHALL BE HIGH FLUX, HIGH POWER WHITE LED <br />PRODUCING A MINIMUM OF 90% OF INITIAL INTENSITY AT 70,000 HOURS OF LIFE. THE <br />LEDS SHALL PROVIDE A COPY OF THEIR TEST DOCUMENTATION TO THE ENGINEER FOR <br />THE IES LM-80 TESTING PROCEDURE. THE LEDS SHALL BE MERCURY AND LEAD FREE. <br />NOMINAL LUMEN EFFICACY SHALL EXCEED 108 LUMENS/W. <br />INDIVIDUAL MICRO —LENS OPTICS SHALL PRODUCE IES TYPE 2 OR TYPE 3 FULL CUTOFF <br />DISTRIBUTIONS WITH 0% LUMENS ABOVE 900 NADIR. THE POWER SUPPLY SHALL HAVE <br />LESS THAN 20% TOTAL HARMONIC DISTORTION AND A MINIMUM POWER FACTOR OF 0.90. <br />THE EMC SHALL MEET OR EXCEED FCC CFR PART 15. TRANSIENT VOLTAGES SHALL <br />COMPLY WITH ANSI C62.41 CAT. A. AN INTEGRAL SURGE PROTECTOR SHALL MEET <br />ANSI/IEEE C62.45, C62.41.2, IEC61000-4-2, AND IEC 61000-4-4. EACH LUMINAIRE <br />SHALL BE PROVIDED WITH A STANDARD 3" X 3" ANSI LABEL INDICATING THE WATTAGE AND <br />THE LIGHT SOURCE TYPE (LED), USING BLACK LETTERS ON A REFLECTIVE WHITE <br />BACKGROUND. <br />THE FINISH SHALL BE A FADE AND ABRASION RESISTANT, EPDXY POLYESTER POWDER <br />COAT WITH A LIGHT GRAY COLOR. THE LUMINAIRE SHALL MEET UL LISTING FOR WET <br />LOCATIONS AND MAINTAIN AN IP66 RATING FOR THE OPTICS COMPARTMENT AND AN IP54 <br />RATING OR BETTER FOR THE POWER COMPARTMENT. <br />SMALL LUMINAIRE (200W HPS RELATIVE EQUIVALENT): <br />TYPE 2 OR TYPE 3 DISTRIBUTION: >_ 9,200 LUMENS <br />MEDIUM LUMINAIRE (250W HPS RELATIVE EQUIVALENT): <br />TYPE 2 OR TYPE 3 DISTRIBUTION: >_ 1 1,700 LUMENS <br />LARGE LUMINAIRE (400W HPS RELATIVE EQUIVALENT): <br />TYPE 2 OR TYPE 3 DISTRIBUTION: >_ 18,000 LUMENS <br />THE FOLLOWING LISTED FIXTURES MEET THE REQUIRED SPECIFICATIONS: <br />SMALL LUMINAIRE: <br />TYPE 2 DISTRIBUTION: <br />LEOTEK GCM 1-60J—MV-40K-2R—GY-095—PCR7-4B—RWG—WL—BSK <br />SCHREDER SMART2—US-24L093—NW—T2M—SV—GY—D01—AA—AB <br />LED ROADWAY NXT-48M-0-7-2LB-5—GY-3—UL—X-4H—BIRD <br />TYPE 3 DISTRIBUTION: <br />LEOTEK GCM 1-60J—MV-40K-3R—GY-095—PCR7-4B—RWG—WL—BSK <br />SCHREDER SMART2—US-24L093—NW—T3M—SV—GY—D01—AA—AB <br />LED ROADWAY NXT-48M-0-7-3LB-5—GY-3—UL—X-4H—BIRD <br />MEDIUM LUMINAIRE: <br />TYPE 2 DISTRIBUTION: <br />LEOTEK GCM1-60J—MV-40K-2R—GY-125—PCR7-4B—RWG—WL—BSK <br />SCHREDER SMART2—US-36L134—NW—T2M—SV—GY—D0I—AA—AB <br />LED ROADWAY NXT-60M-0-7-2LB-5—GY-3—UL—X-4H—BIRD <br />TYPE 3 DISTRIBUTION: <br />LEOTEK GCM 1-60J—MV-40K-3R—GY-125—PCR7-4B—RWG—WL—BSK <br />SCHREDER SMART2—US-361_134—NW—T3M—SV—GY—D01—AA—AB <br />LED ROADWAY NXT-60M-0-7-3LB-5—GY-3—UL—X-4H—BIRD <br />LARGE LUMINAIRE: <br />TYPE 2 DISTRIBUTION: <br />LEOTEK GCM3-60J—MV-40K-2R—GY-185—PCR7-4B—RWG—WL—BSK <br />SCHREDER SMART3—US-48L185—NW—T2M—SV—GY—D01—AA—AB <br />LED ROADWAY NXT-72M-0-7-2LB-7—GY-3—UL—X-4H—BIRD <br />TYPE 3 DISTRIBUTION: <br />LEOTEK GCM3-60J—MV-40K-3R—GY— 1 85—PCR7-4B—RWG—WL—BSK <br />SCHREDER SMART3—US-481_185—NW—T3M—SV—GY—D01—AA—AB <br />LED ROADWAY NXT-72M-0-7-3LB-7—GY-3—UL—X-4H—BIRD <br />LUMINAIRES <br />SECTION 9-29.10 IS SUPPLEMENTED WITH THE FOLLOWING: <br />THE CONTRACTOR SHALL INSTALL THE POLE AND BRACKET CABLE TO THE END OF THE <br />LUMINAIRE ARM WITH THIRTY (30) INCHES OF EXCESS WIRE TO HOOK UP THE LUMINAIRE. <br />CONVENTIONAL ROADWAY LUMINAIRES <br />SECTION 9-29.10(1) IS SUPPLEMENTED WITH THE FOLLOWING: <br />THE CONTRACTOR SHALL CHOMLVU TI fMKLSW Em FWMLrFACTOSELI�\IM <br />SPECIFICATIONS: SERIES SMARTLUMETM ROADWAYTM <br />LUMINAIRE SMART2—US SERIES NXTTM <br />MANUFACTURER LEOTEK TM LAMP 24L OR 36L LUMINAIRE NXT—M <br />SERIES GREEN COBRA TM COLOR TEMP 4000°K LAMP 60M <br />LUMINAIRE GCA1 OPTICAL SYSTEM 2 OR 3 COLOR TEMP 4500°K <br />LAMP 60F OR 80F LED OR VOLTAGE 120-277V OR OPTICAL SYSTEM 3LB <br />COLOR TEMP 4300°K FINISH GY (GREY) VOLTAGE 120-277V <br />OPTICAL SYSTEM 2 OR 3 FINISH GY (GREY) <br />VOLTAGE 120-277V <br />FINISH GY (GREY) <br />COVER MARKINGS: <br />SECTION 9-29.2(4) IS SUPPLEMENTED WITH THE FOLLOWING: <br />JUNCTION BOX IDENTIFICATION <br />JUNCTION BOXES, PULL BOXES AND CABLE VAULTS SHALL BE MARKED WITH THE <br />APPROPRIATE LEGEND IN ACCORDANCE WITH THE BEAD WELD DETAILS IN THE STANDARD <br />PLANS AND PER 9-29.2(4). JUNCTION BOXES, PULL BOXES AND CABLE VAULTS <br />CONTAINING ONLY TRAFFIC SIGNAL INTERCONNECT (FIBER OPTIC OR TWISTED PAIR) CABLE <br />SHALL BE MARKED OR EMBOSSED WITH THE LEGEND "COMM". <br />JUNCTION BOXES: <br />SECTION 9-29.2 IS SUPPLEMENTED WITH THE FOLLOWING: <br />ALL JUNCTION BOXES SHALL CONFORM TO THE DETAILS SHOWN ON THE WSDOT STANDARD <br />DRAWINGS J-40 SERIES, CITY OF EVERETT STANDARD DRAWING 805, AND SHALL BE OF <br />THE TYPE INDICATED IN THE PLANS. ALL JUNCTION BOX LIDS AND FRAMES SHALL BE <br />GALVANIZED AND THOSE INSTALLED WITHIN SIDEWALK AREAS SHALL BE SLIP —RESISTANT. <br />ALL JUNCTION BOXES SHALL HAVE BASE SECTIONS AS SHOWN IN CITY OF EVERETT <br />STANDARD DRAWING 805. ALL JUNCTION BOXES TO BE LOCATED IN THE STREET OR <br />SHOULDER AREA SHALL BE HEAVY DUTY JUNCTION BOXES AS DETAILED IN STANDARD <br />PLAN 1-40.20 AND DESCRIBED IN SECTION 9-29.2(1)B. <br />VAULTS SHALL BE AS INDICATED ON THE DRAWINGS SHALL BE 233—LA, 444—LA AND <br />504—LA, OR APPROVED EQUIVALENT. LIDS FOR THE VAULTS SHALL BE 23-2436P, <br />44-332P AND 55-332P, RESPECTIVELY AND SHALL BE SLIP —RESISTANT. <br />ALL JUNCTION BOXES AND VAULTS PLACED IN SIDEWALK OR PEDESTRIAN PATH SHALL <br />MEET A GAP ACCEPTANCE REQUIREMENT OF NO MORE THAN %" WIDE WITH GREATER THAN <br />�/" DEEP DEPRESSION. ANY JUNCTION BOXES OR VAULTS THAT DO NOT MEET THE GAP <br />ACCEPTANCE REQUIREMENT WILL BE REJECTED. <br />CONCRETE JUNCTION BOXES <br />SLIP —RESISTANT TREATMENT ON VAULTS, SLIP —RESISTANT LID, AND SLIP —RESISTANT FRAME <br />SHALL BE TREATED WITH MEBAC#1 AS MANUFACTURED BY IKG INDUSTRIES, OR SLIPNOT <br />GRADE 3—COARSE AS MANUFACTURED BY W.S. MOLNAR CO, OR SAFTRAX TH604 BY <br />THERMION, INC. WHERE THE EXPOSED PORTION OF THE FRAME IS 1/2 INCH WIDE OR <br />LESS THE SLIP —RESISTANT TREATMENT MAY BE OMITTED ON THAT PORTION OF THE <br />FRAME. THE SLIP —RESISTANT LID SHALL BE IDENTIFIED WITH PERMANENT MARKING ON THE <br />UNDERSIDE INDICATING THE TYPE OF SURFACE TREATMENT ("M1" FOR MEBAC#1; OR "S3" <br />FOR SLIPNOT GRADE 3—COARSE, OR TH FOR THERMION) AND THE YEAR MANUFACTURED. <br />THE PERMANENT MARKING SHALL BE 1/8 INCH LINE THICKNESS FORMED WITH A MILD <br />STEEL WELD BEAD. <br />LIGHT STANDARDS: <br />SECTION 9-29.6 IS SUPPLEMENTED WITH THE FOLLOWING: <br />LIGHT STANDARDS OR SIGNAL STANDARDS MAY BE PAINTED OR FINISHED AS IDENTIFIED IN <br />THE PLANS AND SPECIFICATIONS. <br />ALL LIGHTING STANDARDS FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE <br />ALUMINUM, GALVANIZED STEEL, OR CONCRETE AS SPECIFIED ON THE PLANS. UNLESS <br />OTHERWISE NOTED ON THE PLANS, ALUMINUM AND STEEL STANDARDS SHALL HAVE LARGE <br />RADIUS DAVIT LUMINAIRE ARMS. MOUNTING HEIGHTS FOR LIGHT FIXTURES SHALL BE 35' <br />UNLESS OTHERWISE INDICATED ON THE PLANS. THE BASE SHALL HAVE 4 ANCHOR BOLTS <br />WITH A NOMINAL 1 1-12" BOLT CIRCLE OR PER THE POLE FABRICATOR'S STANDARDS FOR <br />THE PARTICULAR POLE. <br />ALL POLES AND ARMS SHALL BE DESIGNED WITH A MINIMUM WEIGHT OF 50 POUNDS FOR <br />THE LUMINAIRE AND TO WITHSTAND PRESSURES CAUSED BY WIND LOADS OF 90 MILES <br />ALL POLES TO BE FURNISHED SHALL MAINTAIN A MINIMUM SAFETY FACTOR ON YIELD <br />STRENGTH AND BASIC WIND PRESSURE PER THE AASHTO RECOMMENDATIONS FOR THE <br />PARTICULAR POLE MATERIAL. <br />THE SHAFTS SHALL BE PROVIDED WITH A 4" X 6" (MINIMUM DIMENSION) FLUSH <br />HANDHOLE NEAR THE BASE DESIGNED TO PREVENT LOSS OF SHAFT STRENGTH AND <br />PROVIDED WITH MATCHING METAL COVERS SECURED WITH STAINLESS STEEL SCREWS OR <br />BOLTS. THE HANDHOLES SHALL BE LOCATED NEAR THE BASE AND ON THE DOWN <br />STREAM SIDE OF TRAFFIC FLOW. A GROUNDING NUT OR PROVISION IN THE HANDHOLE <br />FRAME FOR ACCOMMODATING A THREADED BOLT FOR THE PURPOSE OF ATTACHING <br />GROUNDING CONNECTOR SHALL BE PROVIDED ON THE INSIDE OF THE SHAFT. <br />ALL STREET LIGHTING POLE SHAFTS SHALL BE ROUND AND TAPERED UNLESS OTHERWISE <br />NOTED ON THE PLANS OR APPROVED BY THE ENGINEER. MATERIAL FOR ALUMINUM <br />POLES SHALL BE NATURAL POLISHED ALUMINUM. <br />ALL BOLTS, NUTS, SCREWS, AND WASHERS, BUT NOT INCLUDING ANCHOR BOLTS AND <br />UNLESS OTHERWISE SPECIFICALLY DESIGNATED HEREIN, SHALL BE STAINLESS STEEL. <br />THE LUMINAIRE ARMS SHALL HAVE A NOMINAL LENGTH AS SHOWN ON THE PLANS <br />MEASURED FROM THE CENTERLINE OF THE SHAFT. THE OUTER PORTION OF THE ARM <br />SHALL BE NEARLY HORIZONTAL TO PLUS 50 ABOVE HORIZONTAL AND SHALL BE <br />FURNISHED WITH A 1-1/2" TO 2" O.D. TENON WITH A MAXIMUM LENGTH OF 10" TO FIT <br />THE LUMINAIRES SPECIFIED HEREIN. <br />FOUNDATIONS FOR STREET LIGHTS SHALL BE IN ACCORDANCE WITH CITY OF EVERETT <br />STANDARD PLAN 812. <br />COMPLETE CALCULATIONS FOR STRUCTURAL DESIGN SHALL BE SUBMITTED WITH THE SHOP <br />DRAWINGS FOR APPROVAL BEFORE FABRICATION OR ORDERING MATERIAL. THESE <br />CALCULATIONS SHALL INCLUDE THE STRESSES IN THE POLE AND MAST ARMS, THE <br />DEFLECTIONS AT THE FREE END OF THE MAST ARM, THE ATTACHMENT OF THE LUMINAIRES <br />TO THE STRUCTURE, THE CONNECTION BETWEEN THE MAST ARMS AND VERTICAL POLE, <br />POLE SECTION AT HANDHOLES, BASE PLATE, ANCHOR BOLTS, AND FOUNDATION. THE <br />SUBMITTAL SHALL INCLUDE THE MATERIAL SPECIFICATIONS AND DETAILS OF THE <br />FOUNDATION AND ANCHOR BOLTS. <br />9-29.6(5) FOUNDATION HARDWARE <br />THE FIRST PARAGRAPH OF SECTION 9-29.6(5) IS REVISED TO READ: <br />ANCHOR BOLTS FOR TYPE PPB, PS, I, FB, AND RM SIGNAL STANDARDS SHALL CONFORM <br />TO THE REQUIREMENTS OF ASTM F1554, GRADE 55. NUTS SHALL MEET THE <br />REQUIREMENTS OF AASHTO M 291, GRADE A. WASHERS SHALL MEET THE REQUIREMENTS <br />OF ASTM F 844 OR ASTM F 436 <br />ELECTIRICAL SPLICE MATERIALS: <br />FUSED QUICK —DISCONNECT KITS <br />SECTION 9-29.7(2) IS SUPPLEMENTED WITH THE FOLLOWING: <br />SOLDERED COMPRESSION CONNECTIONS ARE NOT ALLOWED. ILLUMINATION FUSED QUICK <br />DISCONNECTS SHALL BE TYPE 65U, SINGLE DISCONNECT PER CONDUCTOR. <br />CONTRACTING AGENCY OWED EQUIPMENT: <br />SECTION 8-20.3(1) IS SUPPLEMENTED WITH THE FOLLOWING: <br />CONTRACTING AGENCY OWNED EQUIPMENT <br />A PORTION OF THE TEMPORARY OR EXISTING ELECTRICAL EQUIPMENT TO BE REMOVED <br />SHALL REMAIN THE PROPERTY OF THE CONTRACTING AGENCY. <br />WHERE CALLED FOR IN THE PLANS, THE FOLLOWING SHALL BE DISCONNECTED, <br />DISMANTLED, AND DELIVERED TO THE CONTRACTING AGENCY: <br />• TRAFFIC SIGNAL CONTROLLER CABINETS, AND ALL AUXILIARY EQUIPMENT AND ETHERNET <br />SWITCHES IN ALL TRAFFIC SIGNAL CABINETS. <br />SIGNAL DISPLAYS AND PEDESTRIAN DISPLAYS WHICH REMAIN THE PROPERTY OF THE <br />CONTRACTING AGENCY SHALL BE DELIVERED TO: <br />CITY OF EVERETT POLE YARD <br />4015 RAILWAY AVE. <br />EVERETT, WA 98201 <br />PHONE: (425) 257-7296 <br />ALL OTHER REMOVED ELECTRICAL EQUIPMENT WHICH REMAINS THE PROPERTY OF THE <br />CONTRACTING AGENCY SHALL BE DELIVERED TO: <br />CITY OF EVERETT SIGNAL SHOP <br />3200 CEDAR ST. <br />EVERETT, WA 98201 <br />PHONE: (425) 257-7296 <br />FIVE DAYS WRITTEN ADVANCE NOTICE SHALL BE DELIVERED TO THE ENGINEER. DELIVERY <br />SHALL OCCUR DURING THE HOURS OF 8:00 A.M. TO 2:00 P.M. MONDAY THROUGH FRIDAY. <br />EQUIPMENT DAMAGED DURING REMOVAL OR DELIVERY SHALL BE REPAIRED OR REPLACED <br />TO THE ENGINEER'S SATISFACTION AT NO COST TO THE CONTRACTING AGENCY. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR UNLOADING THE EQUIPMENT WHERE <br />DIRECTED BY THE ENGINEER AT THE DELIVERY SITE. <br />CONTRACTOR OWNED REMOVALS <br />ALL REMOVALS ASSOCIATED WITH AN ELECTRICAL SYSTEM, WHICH ARE NOT DESIGNATED TO <br />REMAIN THE PROPERTY OF THE CONTRACTING AGENCY, SHALL BECOME THE PROPERTY OF <br />THE CONTRACTOR AND SHALL BE REMOVED FROM THE PROJECT. ALL CONCRETE SIGNAL <br />POLES, LUMINAIRES, AND OTHER EQUIPMENT NOT LISTED ABOVE SHALL BE THE PROPERTY <br />OF THE CONTRACTOR AND REMOVED FROM THE PROJECT. <br />THE CONTRACTOR SHALL: <br />REMOVE ALL WIRES FOR DISCONTINUED CIRCUITS FROM THE CONDUIT SYSTEM. <br />REMOVE ELBOW SECTIONS OF ABANDONED CONDUIT ENTERING JUNCTION BOXES. <br />ABANDONED CONDUIT ENCOUNTERED DURING EXCAVATION SHALL BE REMOVED TO THE <br />NEAREST OUTLETS OR AS DIRECTED BY THE ENGINEER. <br />REMOVE FOUNDATIONS ENTIRELY, UNLESS THE PLANS STATE OTHERWISE. <br />BACKFILL VOIDS CREATED BY REMOVAL OF FOUNDATIONS AND JUNCTION BOXES. <br />BACKFILLING AND COMPACTION SHALL BE PERFORMED IN ACCORDANCE WITH SECTION <br />2-09.3(1)E. <br />ADJUST JUNCTION BOX: <br />SECTION 8-20.3(6) IS SUPPLEMENTED WITH THE FOLLOWING: <br />STANDARD DUTY PULL BOXES, CABLE VAULTS AND CONCRETE JUNCTION BOXES INSTALLED <br />IN SIDEWALKS, WALKWAYS AND SHARED USE PATHS SHALL HAVE SLIP RESISTANT <br />SURFACES, BE FLUSH WITH SURFACE AND MATCH GRADE OF THE SIDEWALK, WALKWAY <br />AND SHARED USE PATH. THE BOXES, VAULTS AND JUNCTION BOXES SHALL NOT BE <br />PLACED IN CURB RAMPS, CURB RAMP LANDINGS, OR THE GUTTER AREAS ASSOCIATED <br />WITH THE CURB RAMPS. STANDARD DUTY NON —CONCRETE JUNCTION BOXES SHALL NOT <br />BE INSTALLED IN SIDEWALKS, WALKWAYS OR SHARED USE PATHS. <br />THE CONTRACTOR SHALL ADJUST EXISTING JUNCTION BOX TO NEW GRADE BY ADJUSTING <br />GRAVEL PAD, IN ACCORDANCE TO WSDOT STANDARD DRAWINGS J-40 SERIES AND SHALL <br />BE OF THE TYPE INDICATED IN THE PLANS. THE ADJUSTMENT OPERATIONS SHALL BE <br />CONDUCTED TO PREVENT DAMAGE TO ANY CONDUITS. ALL PARTS OR MATERIALS DAMAGED <br />AS A RESULT OF THE CONTRACTOR'S OPERATIONS SHALL BE REPLACED AT NO EXPENSE <br />TO THE CONTRACTING AGENCY. <br />IF THE JUNCTION BOX IS REMOVED AND RESET, THE PATCH MATERIAL USED AROUND THE <br />JUNCTION BOX SHALL BE THE SAME AS THE ADJACENT PAVEMENT. FOR ASPHALT <br />CONCRETE PAVEMENT ROADWAYS, JUNCTION BOXES LOCATED IN THE TRAVELED WAY SHALL <br />BE ADJUSTED TO FINAL GRADE AFTER FINAL PAVING IN ACCORDANCE WITH SECTION <br />5-04.3(13). FOR PORTLAND CEMENT CONCRETE PAVEMENT ROADWAYS, VALVE BOXES <br />SHALL BE ADJUSTED PRIOR TO THE SURFACE FINISH. <br />ALL JUNCTION BOXES AND VAULTS PLACED IN SIDEWALK OR PEDESTRIAN PATH SHALL <br />MEET A GAP ACCEPTANCE REQUIREMENT OF NO MORE THAN �/2❑ WIDE WITH GREATER THAN <br />1/❑ DEEP DEPRESSION. ANY JUNCTION BOXES OR VAULTS THAT DO NOT MEET THE GAP <br />ACCEPTANCE REQUIREMENT WILL BE REJECTED. <br />ALL JUNCTION BOXES AND VAULTS INSTALLED IN SIDEWALK AREAS SHALL HAVE NON—SKID <br />COVERS. BOTH THE SLIP —RESISTANT LID AND SLIP —RESISTANT FRAME SHALL BE TREATED <br />WITH MEBAC#1 AS MANUFACTURED BY IKG INDUSTRIES, OR SLIPNOT GRADE 3—COARSE AS <br />MANUFACTURED BY W.S. MOLNAR CO, OR SAFTRAX TH604 BY THERMION, INC. WHERE THE <br />EXPOSED PORTION OF THE FRAME IS �h INCH WIDE OR LESS THE SLIP —RESISTANT <br />TREATMENT MAY BE OMITTED ON THAT PORTION OF THE FRAME. THE SLIP —RESISTANT LID <br />SHALL BE IDENTIFIED WITH PERMANENT MARKING ON THE UNDERSIDE INDICATING THE TYPE <br />OF SURFACE TREATMENT (❑M 1 ❑ FOR MEBAC#1 ; OR 11S311FOR SLIPNOT GRADE 3—COARSE, <br />OR TH FOR THERMION) AND THE YEAR MANUFACTURED. THE PERMANENT MARKING SHALL <br />BE 1/8 INCH LINE THICKNESS FORMED WITH A MILD STEEL WELD BEAD. <br />CABLE RACKING IN PULL BOXES AND CABLE VAULTS <br />THE CONTRACTOR SHALL RACK THE CABLE IN VERTICAL FIGURE EIGHT LOOPS, WHICH <br />SHALL PERMIT PULLING SLACK FROM THE VAULTS WITHOUT INTRODUCING TWIST TO THE <br />CABLE. <br />CABLES SHALL BE SECURED IN RACKED POSITIONS WITH NYLON TIES. IDENTIFICATION OR <br />WARNING TAGS SHALL BE SECURELY ATTACHED TO THE CABLES IN AT LEAST TWO <br />LOCATIONS IN EACH PULL BOX OR CABLE VAULT. <br />ALL COILED CABLE SHALL BE PROTECTED TO PREVENT DAMAGE TO THE CABLE AND <br />FIBERS. RACKING SHALL INCLUDE SECURING CABLES TO BRACKETS (RACKING HARDWARE) <br />THAT EXTEND FROM THE SIDE WALLS OF THE PULL BOX. <br />ALL RACKING HARDWARE SHALL BE STAINLESS STEEL. <br />at&t <br />Mobility <br />Network Solutions <br />i ` ` <br />lr"f-PASTRUCTUP.E SEPVICES <br />2227 W PECOS RD, SUITE 4 <br />CHANDLER, AZ 85224 <br />WAEVT-004-B <br />SCIP ID: 17726-004-B <br />ADDRESS: <br />4030 COLBY AVE <br />EVERETT, WA 98201 <br />COUNTY: <br />SNOHOMISH COUNTY <br />10411v- <br />TCCTTL'Tl L,l1D. <br />Z V V V Li! i V �_• <br />REV <br />DATE <br />1 <br />DRWN B <br />DESCRIPTION <br />QA/QC <br />A <br />11 / 15/ 18 <br />SBP <br />PCD FOR REVIEW <br />CW <br />0 <br />04/10/19 <br />SBP <br />CONSTRUCTION SET <br />CW <br />1 <br />06/ 11 / 19 <br />SBP <br />CLIENT COMMENTS <br />CW <br />2 <br />07/19/19 <br />SBP <br />CLIENT COMMENTS <br />CW <br />3 <br />08/14/19 <br />SBP <br />CLIENT COMMENTS <br />CW <br />4 <br />1 11/20/19 <br />SBP <br />CLIENT COMMENTS <br />CW <br />5 <br />12/ 11 / 19 <br />SBP <br />CLIENT COMMENTS <br />CW <br />6 <br />03/18/20 <br />SBP <br />CLIENT COMMENTS <br />CW <br />7 <br />11/10/20 <br />JD <br />GENERAL, UPDATES <br />CW <br />8 <br />08/03/21 <br />JD <br />JDX COMMENTS <br />CW <br />9 <br />11/09/21 <br />JD <br />JDX COMMENTS <br />CW <br />N, EXA <br />WAsy� F9 <br />C-0� �z <br />57449 <br />FsSFG/s7f_ <br />�ONAL� <br />NNa/y%c� <br />SIGNED, 10 NOV2021 <br />EXPIRES, 3 FEB 2022 <br />IT IS A VIOLATION OF LAW FOR ANY PERSON, <br />UNLESS THEY ARE ACTING UNDER THE DIRECTION <br />OF A LICENSED PROFESSIONAL ENGINEER, <br />TO ALTER THIS DOCUMENT. <br />SHEET NUMBER: <br />T 3 <br />'ISION: <br />9 <br />THE STREET LUMINAIRES SHALL MEET OR EXCEED THE FOLLOWING INITIAL DELIVERED <br />