My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3800 RIVERFRONT BLVD 2025-07-23
>
Address Records
>
RIVERFRONT BLVD
>
3800
>
3800 RIVERFRONT BLVD 2025-07-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/23/2025 3:49:01 PM
Creation date
6/18/2025 10:18:28 AM
Metadata
Fields
Template:
Address Document
Street Name
RIVERFRONT BLVD
Street Number
3800
Imported From Microfiche
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br />Consent Decree Exhibit C <br />air pollutant background concentrations are from the Agency for Toxic Substances and Disease <br />Registry (ATSDR) toxicological profiles. <br />In some cases, both the background concentration and the cleanup level calculated by Method <br />B are lower than the Practical Quantitation Limit (PQL) for that particular compound. In those <br />cases, MTCA allows the PQL to be used as the cleanup level [WAC 173-340-700(6)]. <br />Table 3-1 presents the cleanup levels for all detected air pollutants at the Everett Landfill/Tire <br />Fire Site. The cleanup level is the concentration calculated by the Method B equation of WAC <br />173-340-750(3). If the Method B level is less than the natural background, then the background <br />concentration is proposed as the cleanup level. If the laboratory PQL is greater than both the <br />Method B concentration and the background concentration, then the laboratory PQL <br />concentration is proposed as the cleanup level. If the compound is not listed in the MTCA <br />CLARC II Update, then no cleanup level is proposed. <br />3.1.3 Nature and Extent of Gas Contamination <br />The following conclusions are derived from the information presented in the Brownfield <br />Feasibility Study (BFS) (FSI, 2000): <br />• Generation of landfill gas is approximately 230 cubic feet per minute (cfm) and is <br />declining at a rate of approximately 7.5 cfm per year over the next ten years. In <br />2010, it is projected to be about 155 cfm and will continue to decline steadily. <br />• The impacts of landfill gas emissions on ambient air do not exceed MTCA cleanup <br />standards. <br />• Insufficient data exists to fully determine the extent and magnitude of subsurface <br />migration of landfill gas beyond the Site boundary. <br />• Landfill gas perimeter monitoring probes along the east, north and west property <br />boundaries are finished in refuse, or in immediate proximity to it, and data from these <br />probes are not representative in relation to establishing whether or not landfill gas is <br />migrating past the Site boundary. These probes are not part of a proposed future <br />compliance monitoring system. Figure 3-1 shows existing landfill gas probes as well <br />as proposed locations for compliance monitoring probes. <br />• Native, organic, peat soils beneath the surface may contribute to the presence of <br />methane on the east and north Site boundaries. <br />• Buried refuse extends beyond some portions of the boundary of the City's property. <br />• There have been two occasions where flammable gas was detected above 100 ppm <br />during off -site building monitoring. One was in a roof drain that connects directly to a <br />manhole of the City's sewer system. The other was recorded from floor cracks <br />where the instrument was drifting between non -detect and a maximum of 120 ppm. <br />Neither measurement has been repeated during subsequent monitoring rounds. <br />• The highest flammable gas concentration measured in the Animal Shelter and <br />Everett Transfer Station from several separate monitoring events was approximately <br />7,000 ppm within the women's restroom floor drain, approximately 15% of the <br />explosive limit of 50,000 ppm. The flammable gas concentration measured just two <br />inches above the floor drain was less than 20 ppm for all monitoring events. There <br />was no evidence of accumulation of methane gas within the restroom above the floor <br />FINAL - March 2001 3-2 Everett Landfill Tire Fire Site <br />Cleanup Action Plan <br />1 <br />1 <br />Ll <br />Ll <br />1 <br />1 <br />1 <br />1 <br />P� <br />1 <br />1 <br />1 <br />1 <br />'1 <br />1 <br />1 <br />1 <br />1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.