My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1410 SEINER DR SOUTH FORK BAKING COMPANY 2025-08-05
>
Address Records
>
SEINER DR
>
1410
>
SOUTH FORK BAKING COMPANY
>
1410 SEINER DR SOUTH FORK BAKING COMPANY 2025-08-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2025 9:54:40 AM
Creation date
6/18/2025 2:28:42 PM
Metadata
Fields
Template:
Address Document
Street Name
SEINER DR
Street Number
1410
Tenant Name
SOUTH FORK BAKING COMPANY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
323
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 <br />BE <br />E <br />[on <br />ME <br />©l <br />F I- <br />SYMBOL LEGEND (QUANTITY SHOWN ARE FOR NEW DEVICES ONLY) <br />SYMBOL QTY T DESCRIPTION MOUNTING REQUIREMENTS SUPPLIER PART NUMBER <br />RCP <br />ADDRESSABLE FIRE ALARM CONTROL PANEL <br />PART INCLUDES ENCLOSURE; MOUNT AT 72" TO TOP <br />NOTIFIER <br />NFW-50X <br />existing <br />FATA <br />REMOTE ANNUNCIATOR - 80 CHARACTER <br />4 SQUARE w/ 2 GANG RING; MOUNTED AT 66" TO TOP <br />existing <br />NOTIFIER <br />N-ANN-80 <br />cM <br />existing <br />INTELLIGENT OUTPUT CONTROL MODULE <br />4 SQUARE DEEP <br />NOTIFIER <br />FCM-1 <br />INTELLIGENT PHOTO SMOKE DETECTOR <br />4 SQUARE DEEP w/ 3" ROUND RING <br />( <br />existing <br />NOTIFIER <br />NP-200 <br />❑F <br />existing <br />INTELLIGENT MANUAL PULL STATION <br />4 SQUARE DEEP w/ 1 GANG RING; MOUNTED AT 48" TO TOP <br />NOTIFIER <br />NOT-BG12LX <br />- <br />existing <br />INTELLIGENT MONITOR MODULE DUAL CIRCUIT <br />4 SQUARE DEEP <br />NOTIFIER <br />NDM-100 <br />120VAC VOLTAGE PROTECTOR for CONTROL PANELS <br />MOUNTS IN 117 OR 3/4" CABINET KNOCKOUT <br />vP <br />existing <br />SPACEAGE <br />E120V-GT <br />w/ LOCKOUT & LABELS <br />aPs-I <br />existing <br />AUXILIARY POWER SUPPLY, 4 NAC CIRCUITS, 8AMP <br />PART INCLUDE BACKBOX; SURFACE MOUNT <br />ALTRONUC <br />AL802ULADA <br />15.5"H x 12"W x 4.5"D <br />WALL HORN wl STROBE: WHITE <br />4 SQUARE DEEP, MOUNTED AT 80" TO BOTTOM <br />SYSTEM <br />3 NEW <br />P2WL <br />SEE DEVICE DESIGNATION FOR STROBE ed SETTING <br />SENSOR <br />® <br />1 NEW <br />WALL STROBE: WHITE <br />4 SQUARE DEEP, MOUNTED AT 80" TO BOTTOM <br />SYSTEM <br />SWL <br />1 existing <br />SEE DEVICE DESIGNATION FOR STROBE ed SETTING <br />SENSOR <br />WALL HORN w/ STROBE: RED: WEATHERPROOF <br />SA-WBB BACK BOX: SURFACE MOUNT AT 80" TO BOTTOM <br />SYSTEM <br />�AT <br />existing <br />P2RK <br />SEE DEVICE DESIGNATION FOR STROBE cd SETTING <br />SENSOR <br />0 <br />existing <br />OUTDOOR BELL; 10"; 24VDC <br />WBB-R, MOUNTED AT 80" TO BOTTOM <br />POTTER <br />PDC1024 <br />® <br />KITCHEN HOOD SUPPRESSION SYSTEM <br />SUPPLIED BY <br />GENERAL CO. <br />® Ts <br />existing <br />FIRE SPRINKLER: WET SYSTEM VALVE <br />SUPPLIED BY <br />WATERFLOW & VALVE TAMPER SWITCH <br />SPRINKLER CO <br />FIRE SPRINKLER: SUPERVISORY SWITCH: <br />SUPPLIED BY <br />0 <br />existing <br />ISOLATION TAMPER, BACKFLOW PREVENTER, PIV, OS&Y or HEAT TAPE <br />SPRINKLER CO <br />WIRE LEGEND <br />SYMBOL IDESCRIPTION THHN FPL FPLP WET COLOR CODING <br />CIRCUIT TYPE <br />A <br />1 PAIR 16AWG FIRE RATED CABLE <br />YES <br />971 <br />60991B <br />AQ225 <br />RED JACKET wl NO STRIPE <br />CONVENTIONAL (IDC) CIRCUIT <br />C <br />1 PAIR 16AWG FIRE RATED CABLE <br />YES <br />971 <br />60991B <br />AQ225 <br />RED JACKET w/ WHITE STRIPE <br />AUDIBLE (NAC) CIRCUIT <br />D <br />1 PAIR 16AWG FIRE RATED CABLE <br />-- <br />971 <br />60991B <br />AQ225 <br />RED JACKET w/ NO STRIPE <br />DATA (SLC) CIRCUIT <br />N <br />1 PAIR 16AWG SHIELDED FIRE RATED CABLE <br />— <br />991 <br />D60990 <br />AQ294 <br />RED JACKET wl ORANGE STRIPE <br />485 NETWORK CIRCUIT <br />P <br />1 PAIR 14AWG FIRE RATED CABLE <br />YES <br />972 <br />60993B <br />AQ226 <br />RED JACKET w/ NEON GREEN STRIPE <br />AUX POWER CIRCUIT <br />GENERAL NOTES: <br />** STRIPES ARE NOT REQUIRED, HOWEVER IT DOES MAKE IT EASIER FOR CIRCUIT IDENTIFICATION. <br />1- WIRE MANUFACTURER IS FOR REFERENCE PURPOSE ONLY. WHEN USING OTHER MANUFACTURE, ENSURE PROPER CROSS REFERENCE <br />2- FPLP CAN BE USED IN MOST ALL APPLICATIONS WITH THE EXCLUSION OF WET AND CIRCUIT INTEGRITY REQUIREMENTS <br />3- INSTALL WIRING PER NEC. USE CABLE TYPE CONSISTENT WITH NEC REQUIREMENTS, IE: PLENUM, RISER, UNDERGROUND, ETC. <br />o\ DATE: <br />0. 1 05/15/202Z SuaMITTAL DRAWINGS <br />DESCRIPTION: <br />106, <br />SOUTH FORK BAKING COMPANY T.I. <br />PORT OF EVERETT WPC - FISHERMAN'S HARBOR <br />COMMERCIAL DEVELOPMENT- PARCEL A8 <br />FIRE ALARM SYSTEM TENANT IMPROVEMENT <br />SEQUENCE OF OPERATIONS <br />PANEL OUTPUTS <br />0 <br />0 <br />J5 <br />1 <br />'.. <br />wI- <br />E <br />cn <br />rn <br />C <br />',' <br />m <br />E <br />o <br />'c <br />0 <br />0 . <br />LU <br />J <br />0 <br />0 <br />' <br />o <br />R <br />o <br />0 <br />O <br />0 <br />`a <br />C <br />C <br />2 <br />- <br />�''� <br />. <br />LEE <br />a) <br />O <br />�Q <br />c <br />� <br />) <br />'p <br />C <br />C <br />0 <br />N <br />' <br />0 <br />rn <br />m'a) <br />U) <br />0 <br />li <br />Q:C <br />�: <br />C <br />Ti <br />n <br />o <br />�-: <br />¢ <br />Ii E— <br />U) <br />0 <br />Alarm From <br />� <br />¢ 'I <br />� <br />U)l <br />0' <br />0 <br />0of <br />Smoke Detector <br />X <br />X 1 <br />X <br />1 <br />X <br />Manual Station <br />X <br />X 1 <br />X <br />1 <br />X <br />Sprinkler Waterflow <br />X <br />X 1 <br />X <br />1 <br />X <br />Kitchen Hood Supression Monitoring <br />X <br />X <br />X <br />X <br />........................................................................................................................................................................................................; <br />Sprinkler Supervisory <br />X <br />X <br />................................................ <br />X <br />X <br />,WN BY: APPROVE BY CLIENT N,I.C.E.T, CERTIFICATION SCALE: e r -- 1r'Orr <br />JCP MS STATEMENT 16 8 6 4 2 0 �� A8 FLOOR PLAN <br />n n n SCALE; 8— T <br />THESE FIRE ALARM DRAWINGS HAVE � � � � <br />BEEN REVIEWED BY: <br />MIKE SERESUN <br />FIRE PROTECTION ENGINEERING <br />TECHNOLOGY <br />FIRE ALARM SYSTEMS - LEVEL III <br />NICET CERTIFICATION #101668 <br />CERTIFICATION EXPIRES-11/01/2024 <br />2 3 4 <br />PROJECT CONTACT INFORMATION: <br />CUSTOMER: <br />NAME: <br />CPM <br />ADDRESS: <br />1509 BONNEVILLE AVE <br />SNOHOMISH, WA 98290 <br />CONTACT: <br />MELANIE IAZEOLLA <br />PHONE: <br />425-330-2243 <br />FAX: <br />EMAIL: <br />miazeolla@cpmnw.com <br />FIRE ALARM I LIFE SAFETY PROVIDER: <br />NAME: ETGFIRE - SPECIAL HAZARDS FIRE PROTECTION <br />ADDRESS: <br />8223BROADWAY <br />EVERETT, WA 98203 <br />PHONE: <br />206-557-3660 <br />FAX: <br />SALESMAN: <br />JOESKVARLA Joe.Skvarla@ETGFire.com <br />PROJECT MANAGER: JAMES PAN james.pan@ETGFire.com <br />DESIGNER: <br />SCOPE OF WORK: <br />I. TENANT IMPROVEMENT TO EXISTING A8 BUILDING. EXISTING BUILDING CORE <br />AND SHELL FIRE ALARM SCOPES WERE COVERED UNDER PERMIT FA2209-003. <br />DESIGN SCOPE IS FOR SOUTH FORK BAKERY TI ONLY. SHADED AREA IS NOT <br />INCLUDED IN THIS PERMIT SCOPE OF WORK. <br />2. ETG IS TO PROVIDE DESIGN & PROGRAMMING. AND INSTALLATIONS ALL TI <br />DEVICES AND TRIMS. <br />3. BUILDING WILL BE EVACUATED ON GENERAL ALARM. ALL EXISTING FIRE <br />ALARM SEQUENCE OF OPERATIONS TO REMAIN THE SAME. <br />4. ALL EXISTING DEVICES ARE SHOWN IN LIGHTER SHADE OR ORANGE COLOR. <br />EXISTING DEVICES TO REMAIN THE SAME UNLESS OTHERWISE NOTED. <br />FIRE PROTECTION AND ALL RIGHTS ARE EXPRESSLY RESERVED. THIS DRAWING IS <br />NOT TO BE USED FOR ANY OTHER PURPOSE NOR COPIED IN WHOLE OR PART NOR <br />ITS DESIGN FEATURES USED IN OTHER PRODUCTS WITHOUT B RAMIE FIRE <br />PROTECTION'S WRITTEN CONSENT. <br />5 1 6 <br />DEVICE DESIGNATION LEGEND: <br />FIREWARDEN SERIES ADDRESSABLE INITIATING DEVICES: <br />BASE 1ADDRESS <br />BASEIOADDRESS <br />9 7 THE DETECTORS & MODULES ON A <br />/ NFW-50ARENOTSHAREDANDMUST <br />BE IN SEQUENTIAL ORDER <br />FOR EXAMPLE'. <br />0I00 <br />5 0 ] O O 10 5 0 O O r n n /� n /� <br />11 M <br />3 12 3 01 02 <br />313 �o <br />TENS ONES <br />NOTIFICATION /VISUAL CIRCUITS: <br />CIRCUIT TYPE'. FLOOR THAT P.S. IS ON <br />"C" = FACP SAC CIRCUIT POWER SUPPLY ID <br />"N" = APB SAC CIRCUIT <br />"P" = 24VDC POWER CIRCUIT SUB -CIRCUIT NUMBER <br />S <br />R' = 24VDC RESET POWER CIRCUIT <br />=STROBE CIRCUIT <br />Z= AUUDIORSERRER CRCUITUIT N '� A -O N1A-2 CIRCUCOMPLETE IT# <br />FORSYSTEMSENSORHORNS HORN DB SETTINGS: FORMEELOCHHORNS <br />ADJUST HORN DB SETTINGS _ _-ADJUST HORN DB SETTINGS <br />sass 1' = IEIIP3 HI y <br />'2' = TEMPS MED i Q <br />'3' = TEMPS LOW 1 1 1 1 1 1 <br />'4" = CONE HI <br />'5'=IMED 9 <br />'6'=CONTLOW <br />ETG F1" RE <br />SPECIAL HAZARDS FIRE PROTECTION <br />3702 W. VALLEY Hwy. N. SUITE 200 <br />AUBURN, WA 98001 <br />AUSTIN-CHEYENNEMDENVERMPASADENA- <br />SALT LAKE-SEATTLEMSPOKANE <br />(206) 557-3660 WWW.ETGFIRE.COM <br />INSTALLATION & GENERAL WIRING NOTES: <br />GENERAL NOTES: <br />1. <br />INSTALLATION SHALL BE ACCOMPLISHED IN STRICT COMPUANCE WITH NFPA, LOCAL AND STATE <br />Ads, NEC AND CONTRACT DRAWINGS <br />2. <br />WIRE ROUTING IS DIAGRAMMATIC IN NATURE ONLY AND NOT INTENDED FOR ACTUAL CONDUIT <br />ROUTING. <br />3. <br />ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ. <br />4. <br />VERIFY ALL LOCATIONS OF DEVICES WITH ELECTRICAL/ARCHITECTURAL PLANS. SCALE AND PLACE <br />ALL DEVICE PER ELECTRICAL/ARCHITECTURAL PLANS. <br />5. <br />ALL CIRCUITS WILL BE PROPERLY TAGGED AND TESTED FOR OPENS, SHORTS, GROUNDS AND <br />PROPER "END -OF -LINE" RESISTANCE. EACH CIRCUITS METER READING MUST BE DOCUMENTED <br />AND PRESENTED TO ETG FIRE FIELD TECHNICIAN UPON ARRIVAL ONSITE FOR STARTUP & <br />CHECKOUT. <br />6. <br />AS-BUILTS: <br />6.1. <br />A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR <br />ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY ETG HIRE TECHNICIAN. <br />6.2. <br />AS-BUILTS SHALL BE KEPT ORDERLY AND BE CLEARLY MARKED WITH DIFFERENT COLOR <br />PENS FOR EACH CIRCUIT AND/OR CIRCUIT TYPE. AS-BUILTS MUST INDICATE CHANGES TO <br />THE FINAL DEVICE INSTALLED LOCATIONS IF NOT INSTALLED AT LOCATION SHOWN ON <br />DESIGN DOCUMENTS. <br />6.3. <br />AS -BUILT REDLINES NOT PROVIDING THIS INFORMATION WILL BE RETURNED TO THE <br />INSTALLATION CONTRACTOR FOR CORRECTION. ETG FIRE IS NOT RESPONSIBLE FOR <br />THESE DELAYS. <br />7. <br />AGREEMENT AND CONFIRMATION OF ALL MILESTONE EVENTS WILL BE MADE WITH EFG ARE <br />PROJECT MANAGER. <br />8. <br />ALL ETG FIRE FIELD SERVICES MUST BE SCHEDULED WITH ETG FIRE PROJECT MANAGER WITH A <br />MINIMUM OF 14 WORKING DAYS ADVANCE NOTICE. <br />9. <br />DO NOT INSTALL LINE VOLTAGE IN SAME CONDUIT AS POWER LIMITED CABLES. <br />FlRE ALARM SPECIFIC NOTES: <br />1. <br />SMOKE DETECTORS SHALL NOT BE INSTALLED WITHIN 36" OF ANY NR DIFFUSER. <br />2. <br />2018 NFPA 72-17.7.1.11 REQUIRES THAT SMOKE DETECTORS SHALL NOT BE INSTALLED UNTIL <br />AFFER FINAL CONSTRUCTION CLEAN-UP. <br />2.1. <br />ANY SMOKE DEFECTORS THAT HAVE BEEN INSTALLED PRIOR TO CLEAN-UP MUST BE <br />CLEANED OR REPLACED AND WILL BE INVOICED ON A TO BASIS. <br />3. <br />WALL MOUNTED NOTIFICATION DEVICES BACKBOX BETWEEN A MINIMUM OF 80" AFF TO A MAXIMUM <br />OF 96' ARE <br />3.1. <br />DEVICES THAT ARE UNABLE TO BE MOUNTED WITHIN THAT RANGE MUST BE VERIFIED BY <br />ETG FIRE PRIOR TO INSTALLATION. <br />3.2. <br />SEE FLOOR PLANS FOR CANDELA RATING OF EACH DEVICE INSTALLED. <br />4. <br />ALL MANUAL PULL STATIONS ARE TO BE MOUNTED AT A HEIGHT NO GREATER THAN 48" TO TOP <br />AND NO LOWER THAN 36" TO BOTTOM (PER ADA REQUIREMENTS). <br />5. <br />FIELD VERIFY ALL SPRINKLER MONITORING DEVICES WITH FIRE PROTECTION CONTRACTOR <br />6. <br />FIELD VERIFY ALL HVAC, FAN CONTROL, FIRE/SMOKE DAMPERS AND DUCT DEFECTORS LOCATIONS <br />WITH MECHANICAL CONTRACTOR <br />7. <br />FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF ETG FIRE TECHNICIANS. <br />B. <br />NO TAPPING OF SIGNALING OR INITIATING ZONE CIRCUITS ARE ALLOWED. T-TAPPING OF STYLE 4 <br />ADDRESSABLE CIRCUITS IS ALLOWED PROVIDING A SPLICE IS PROFESSIONALLY INSTALLED, <br />POLARITY IS OBSERVED AND SHIELDS ARE CONTINUOUS AND FREE OF GROUNDS. SHIELDS MUST <br />BE TERMINATED AT FACP ONLY. <br />8.1. <br />CABLE SHIELDS SHALL BE SPLICED TOGETHER AT EVERY JUNCTION BETWEEN THE FACP <br />AND THE LAST DEVICE ON EACH CABLE RUN. SHIELDS AND OTHER FIRE ALARM <br />CONDUCTORS (EXCEPT POWER GROUNDS) SHALL BE INSULATED AND COMPLETELY FREE <br />FROM CONDUIT OR EARTH GROUNDS. SHIELDS WILL BE TIES TO GROUND ONLY AT THE <br />FACP BY THE ETG FIRE FIELD TECHNICIAN. <br />9. <br />THE SYSTEM SHALL BE MONITORED BY A U.L. LISTED MONITORING STATION BEFORE AHJ TEST. <br />10. <br />AS-BUILTS ARE REQUIRED AT TIME OF AHJ ACCEPTANCE. ETG ARE REQUIRED ELECTRICAL RED <br />LINES WITHIN 2 WEEKS PRIOR TO AHJ TESTS. <br />10.1. <br />EACH CIRCUIT (SLC, NAC OR POWER) MUST BE CLEARLY IDENTIFIED WITH A DISTINCT <br />COLOR <br />10.2. <br />EACH NAC CIRCUIT MUST BE CLEARLY MARKED AS TO WHICH DEVICES ARE ON EACH <br />CIRCUIT AND IN THE ORDER THE DEVICES ARE WIRED TO COMPLETE THE CIRCUIT. <br />SHEET SCHEDULE: <br />PAGE # SHEET # <br />DESCRIPTION <br />1 <br />FAS-1.00 <br />PROJECT & DESIGN INFO. <br />2 <br />FAS-1.01 <br />SYSTEM CALCULATIONS <br />-- <br />-- End of List - <br />Mi Iwrighl Lp N <br />JCP 1 05/15/2023 <br />JCP 1 05/15/2023 <br />NICET OR PE REVIEW. DATE <br />MS <br />Hotel Indigo <br />Seattle Everett.. <br />PROJECT SITE <br />Neigh <br />8[h s, <br />ij <br />a <br />n <br />141h st <br />I <br />Amemmns>a_ <br />T <br />C <br />E <br />O�The Parlor Salon P <br />'v <br />In AVEnu ., i6ths, <br />',w dge <br />Grand <br />Avenue Fade <br />I y <br />SITE MAP UN <br />NOT TO SCALE <br />SOUTH FORK BAKING COMPANY TENANT IMPROVEMENTS <br />PORT OF EVERETT WPC - FISHERMAN S HARBOR <br />COMMERCIAL DEVELOPMENT - PARCEL A8 <br />FIRE ALARM SYSTEM TENANT IMPROVEMENT <br />SCALE SHEET DESCRIPTION. SHEET. <br />FIRE ALARM SYSTEMI F F /� S-1 0� <br />AS SHOWN PROJECT&DESIGN INFO. //'"'�� <br />PROJECT #: 301230023 <br />8 9 <br />I0 <br />CIO <br />IEI <br />IFI <br />
The URL can be used to link to this page
Your browser does not support the video tag.