Laserfiche WebLink
EVERETT 2044 <br />DEVELOPMENT REGULATIONS <br /> <br /> <br />6/17/2025 <br />DEVELOPMENT REGULATIONS <br />Page 71 <br />This standard applies to lots used for single-family detached dwellings. See EMC 19.08.030 for additfonal 1 <br />lot requirements applicable to other housing types. Not more than one single-family detached dwelling 2 <br />may be permitted unless meetfng the minimum lot area required in the R-S, R-1 and R-2 zones unless 3 <br />otherwise allowed by this tftle. 4 <br />(3) In the R-2 zone, minimum lot area for single-family dwellings with alley access shall be four thousand 5 <br />five hundred square feet. Any lot under five thousand square feet in area shall be subject to the small lot 6 <br />single-family provisions in EMC 19.08.020. 7 <br />19.06.020, BUILDING SETBACKS/BUILDING PLACEMENT STANDARDS. 8 <br />A. Minimum Building Setbacks for Principal Structures. The standards set forth in Table 6-2 below apply 9 <br />to all new development. Also refer to Chapter 19.22 EMC, Building and Structure Heights. 10 <br />Table 6-2: Minimum Building Setbacks for Principal Structures 11 <br />ZONE <br />R-S <br />NR-C <br />R-1 <br />NR <br />R-2 <br />UR4 <br />R-2(A) <br />UR7 <br />UR3 <br />MU4 <br />UR4 <br />MU7 <br />NB <br />MU15 <br />B <br />MU25 <br />MU <br />LI1 <br />LI-MU <br />LI2 <br />LI <br />HI AG <br />Minimum <br />Setback: <br />Front 20' 20' <br />10’ <br />20' <br />None <br />20' <br />None <br />20' <br />None <br />10' <br />None None None None None 20' None 25' <br />Rear (with <br />alley) 20'(5) 20' <br />None <br />20' <br />None <br />20' <br />None <br />20' <br />None None None None None None None(1) 10'(1) 25' <br />Rear (no <br />alley) 20' 20' <br />10’ 5' <br />20' <br />10’ 5’ <br />20' <br />None(2) <br />20' <br />None(2) <br />10'(3) <br />None(2) <br />10' <br />None(2) None(2) None(2) None(2) 15'(1) 10'(1) 25’ <br />Side, Street 10' 10' <br />5’ <br />10' <br />5' <br />10' <br />None <br />10' <br />None <br />10' <br />None <br />10' <br />None None None None 20' None 10' <br />Side, <br />Interior 5'(5) 5'(5) 5' <br />5’(3) <br />5' <br />None(3) <br />5' <br />None(2) <br />5'(4) <br />None(2) <br /> 5' <br />None(2) <br />(2) <br />None None None(2) 15'(1) None(1) 10' <br />Footnotes: 12 <br />(1) Twenty-five feet when abutting lots located in residentfal zones. 13 <br />(2) Ten feet when abutting lots located in residentfal zones, except within Centers. 14 <br />(3) Ten feet when abutting lots located in the NR zone.Twenty feet when abutting lots located in 15 <br />the R-S, R-1 and R-2 zones. 16 <br />(4) No side, interior setback is required within Metro EverettCenters 17 <br />(5) No side, interior setback required when the side lot line abuts an alley 18 <br />B. Average Front Setback—Residentfal Structures in Residentfal Zones. In certain instances, existfng 19 <br />residentfal dwellings do not meet the current front setback standard for the applicable zone district. In 20