Laserfiche WebLink
I 1 2 3 4 5 6 7 8 9 <br /> SYMBOL LEGEND(QUANTITY SHOW RNEWDEVICESO SOUTH FORK BAKING COMPANY T.I. DEVICE DESIGNATION LEGEND: INSTALLATION&GENERAL WIRING NOTES: <br /> MOUNTING <br /> SYMBOL OTY s DESCRIPTIONPTION MOUNTING REQUIREMENTS SUPPLIER PART NUMBER <br /> ADDRESSABLE FIRE ALARM CONTROL PANEL PART INCLUDES ENCLOSURE;MOUNT AT 72'TO TOP <br /> existing NOTIFIER NFw-sox FIREWARDEN SERIES ADDRESSABLE INITIATING DEVICES: GENERA NOTES: <br /> PORT O F EVERETT WPC - FISHERMAN'S S HARBOR INSTALLATION NEC SHALL BE CTACCOMPLISHED IN STRICT COMPLIANCE WITH NFPA LOCAL AND STATE <br /> 7A 0 ezis4ng REMOTE ANNUNCIATOR,80 CHARACTER 4 SQUARE w/2 GANG RING;MOUNTED AT 66'TO TOP NOTIFIER N-ANN-80 AHJ S' <br /> NEC AND CONTRACT DRAWINGS q <br /> BASEIADDRESS 2. WIRE ROUTING IS DIAGRAMMATIC IN NATURE ONLY AND NOT INTENDED FOR ACTUAL CONDUIT <br /> INTELLIGENT OUTPUT CONTROL MODULE 4 SQUARE DEEP ROUTING. <br /> cnI ezis4ng NOTIFIER FCM-1 COMMERCIAL DEVELOPMENT PARCEL A8 BASE 10ADDAESS 3. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ. <br /> INTELLIGENT PHOTO SMOKE DETECTOR 4 SQUARE DEEP w/3'ROUND RING 4. VERIFY ALL LOCATIONS OF DEVICES WITH ELECTRICAL/ARCHITECTURAL PLANS. SCALE AND PLACE <br /> �P existing INTELLIGENT NP-200 ALL DEVICE PER ELECTRICAL/ARCHITECTURAL PLANS. <br /> r ezis4ng INTELLIGENT MANUAL PULL STATION 4 SQUARE DEEP wl 1 GANG RING;MOUNTED AT 48"TO TOP NOTIFIER NOT-BG12LX FIRE ALARM SYSTEM TENANT IMPROVEMENT 5. ALL CIRCUITS WILL BE PROPERLY TAGGED AND TESTED FOR OPENS,SHORTS,GROUNDS AND <br /> THE DEFECTORS PROPER°END-OF-LANE°RESISTANCE. EACH CIRCUITS METER READING MUST BE DOCUMENTED <br /> 9 7 NFW50ARE NOT SHARED AND MUST AND PRESENTED TO ETG ARE FIELD TECHNICIAN UPON ARRIVAL ONSITE FOR STARTUP& <br /> Q existing INTELLIGENT MONITOR MODULE DUAL CIRCUIT 4 SQUARE DEEP NOTIFIER NDM-100 BE IN SEQUENTIAL ORDER CHECKOUT. <br /> FOREXAMPIE: 6. AS-BUILT$: <br /> El 120VAC VOLTAGE PROTECTOR for CONTROL PANELS MOUNTS IN 1/2"OR 314'CABINET KNOCKOUT D D D 6.1. A SET OF INSTALLATION AS-BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR <br /> ezis4ng SPACEAGE E120V-GT A A A <br /> w/LOCKOUTB LABELS SEQUENCE OF OPERATIONS '� ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE m'ETG FIRE TECHNICIAN. <br /> AUXILIARY POWER SUPPLY,4 MAC CIRCUITS,RAMP PART INCLUDE BACKBOX;SURFACE MOUNT PROJECT CONTACT INFORMATION: ,S .1'2 01 02 6.2. AS-BUILTS SHALL BE KEPT ORDERLY AND BE CLEARLY MARKED WITH DIFFERENT COLOR <br /> +ry existing ALTRONIX AL802ULADA PANEL OUTPUTS "���/// PENS FOR EACH CIRCUIT AND/OR CIRCUIT TYPE. AS-BUILTS MUST INDICATE CHANGES TO <br /> 15.SH z 12'W z 4.5°D <br /> WALL HORN w/STROBE:WHITE 4 SQUARE DEEP;MOUNTED AT 80'TO BOTTOM SYSTEM CUSTOMER: THE FINAL DEVICE INSTALLED LOCATIONS IF NOT INSTALLED AT LOCATION SHOWN ON <br /> 3 NEW SEE DEVICE DESIGNATION FOR STROBE cd SETTING SENSOR P2WL NAME: CPM ❑re os DESIGN DOCUMENTS. <br /> 1 NEW WALL STROBE:WHITE 4 SQUARE DEEP;MOUNTED AT 80'TO BOTTOM SYSTEM o ADDRESS:1509 BONNEVILLE AVE 6.3. AS-BUILT REDLINES NOT PROVIDING THIS INFORMATION WILL BE RETURNED i0 THE <br /> 1 ezis4 SEE DEVICE DESIGNATION FOR STROBE cd SETTING SENSOR � NOTIFICATION)VISUAL CIRCUITS: INSTALLATION CONTRACTOR FOR CORRECTION. ETG <br /> ® SOUL FIRE IS NOT RESPONSIBLE FOR <br /> `0 n SNOHOMISH,WA 98290 THESE DELAYS. <br /> 61, WALL HORN wl STROBE:RED:WEATHERPROOF SA-WBB BACK BOX SURFACE MOUNTAT BO"TO BOTTOM SYSTEM CIRCUIT TYPE. FLOOR THAT P.S.IS ON 7. AGREEMENT AND CONFIRMATION OF ALL MILESTONE EVENTS WILL BE MADE WITH ETG ARE <br /> existing P2RK CONTACT:MELANIE IAZEOLLA <br /> SEE DEVICE DESIGNATION FOR STROBE cd SETTING SENSOR N rn c 'C"=FACP NAC CIRCUIT POwERSUPRYIo PROJECT MANAGER. <br /> OUTDOOR BELL;10';24VDC WBB-R MOUNTED AT 80'TO BOTTOM PHONE: 425330.2243 'N"=APSNACCIRCUITFF 8. ALL ETG FIRE FIELD SERVICES MUST BE SCHEDULED WITH ETG FIRE PROJECT MANAGER WITH A <br /> Q existing POTTER PDC1024 g. `o 0 0 'P 24VDC POWER CIRCUIT SUBLIRCUITNUMBER MINIMUM OF 14 WORKING DAYS ADVANCE NOTICE. <br /> B _ .� E C J FAX; 'RI-24VDC RESET POWER CIRCUIT <br /> Q KITCHEN HOOD SUPPRESSION SYSTEM SUPPLIED BY 's'=STROBE CIRCUIT 9. DO NOT IN <br /> LINE VOLTAGE IN SAME CONDUIT AS POWER LIMITED CABLES. B <br /> € o `o EMAIL: miazeDlla c mnw.wm v'=VOICBSPEAK RCRCUIT N1A2 coMPLETE <br /> GENERALCO. m 'Z'=AUgO RISER CIRCUR N I A -O CIRCUIT# <br /> FIRE SPRINKLER:WET SYSTEM VALVE SUPPLIED BY c e c `3 .9 FIREALARMILIFESAFETYPROVIDER: <br /> existing _ ARE ALARM SPECIFIC NOTES: <br /> WA <br /> TERFLOW B VALVE TAMPER SWITCH SPRINKLER CO. O �_ NAME: ETG FIRE.SPECIAL HAZARDS FIRE PROTECTION FOR SYSTEM SENSOR HORNS. HORN DB SETTINGS: FOR HEMLOCK HORNS: <br /> IF SPRINKLER:SUPERVISORY SWITCH: SUPPLIED BY E ' Z ADJUSTHORN DB SETTINGS ___ADIUSTHORNDBSETTINGS 1. SMOKE DETECTORS SHALL NOT BE INSTALLED WITHIN 36'OF ANY AIR DIFFUSER. <br /> O ezis4ng ISOLATION TAMPER BACKFLOW PREVENTER,PN,OS&Y or HEAT TAPE SPRINKLER CO. c rn m Q ADDRESS:8223 BROADWAY =__-====y 2. 2018 NFPA 72-17.7.1.11 REQUIRES THAT SMOKE DETECTORS SHALL NOT BE INSTALLED UNTIL <br /> z, t e a s s 9"=TOP <br /> HI AFTER ANAL CONSTRUCTION CLEAN-UP. <br /> y € EVERETT,WA 98203 '2"=IEMPJ MID 0 2.1. ANY SMOKE DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO CLEAN-UP MUST BE <br /> W n I' TIMPJ LOW V <br /> o_ a � co Ug PHONE: 206-557-3660 4-WNT HI CLEANED OR REPLACED AND WILL BE INVOICED ON A T&M BASIS. <br /> WIRE LEGEND € > > > c 's'-DONTMID <br /> Alarm From LL ¢ in cai cai cai m FAX: 's'=cDNT Low a 3. WALL MOUNTED NOTIFICATION DEVICES 81CKBOX BETWEEN A MINIMUM OF 80°AFT TO A MAXIMUM <br /> SYMBOL DESCRIPTION THHN FPL FPLP WET COLOR CODING CIRCUITTYPE OF 96'AFF. <br /> A 1 PAIR 16AWG FIRE RATED CABLE YES 971 1 60991B AQ225 RED JACKET w/NO STRIPE ICONVENTIONAL DDC)CIRCUIT Smoke Detector X X X X SALESMAN: JOE SKVARLA Joa$kvada@ETGFim.CDm 3.1. DEVICES THAT ARE UNABLE TO BE MOUNTED WITHIN THAT RANGE MUST BE VERIFIED BY <br /> C 1 PAIR 16AM FIRE RATED CABLE YES III 809918 AQ225 RED JACKET w/WHITE STRIPE AUDIBLE NAC CIRCUIT Manual Station X X X X PROJECT MANAGER: JAMES PAN james.pan@ETGFire.com ETG FIRE PRIOR TO INSTALLARON. <br /> D 1 PAIR IGAWG FIRE RATED CABLE - 971 60991E AQ225 RED JACKET w/NO STRIPE DATA SLC CIRCUIT Sprinkler Waterfow X X X X DESIGNER: 3.2. SEE FLOOR PLANS FOR CANDELA RATING OF EACH DEVICE INSTALLED. <br /> N 1 PAIR 16AWG SHIELDED FIRE RATED CABLE - 991 D60990 AQ294 RED JACKET NO ORANGE STRIPE 485 NETWORK CIRCUIT KBchen Hood Supression Monitoring X X X X 4. ALL MANUAL PULL STATIONS ARE TO BE MOUNTED AT A HEIGHT NO GREATER THAN 48"TO TOP <br /> P 1 PAIR 14AWG FIRE RATED CABLE YES 972 60993B AQ226 RED JACKET w/NEON GREEN STRIPE AUX POWER CIRCUIT AND NO LOWER THAN 36'TO BOTTOM(PER ADA REQUIREMENTS). <br /> GENERAL NOTES: Sprinkler Supervisory X X X X SCOPE OF WORK: 5. HELD VERIFY ALL SPRINKLER MONITORING DEVICES WITH ARE PROTECTION CONTRACTOR <br /> STRIPES ARE NOT REQUIRED,HOWEVER IT DOES MAKE IT EASIER FOR CIRCUIT IDENTIFICATION. I. TENANT IMPROVEMENT TO EXISTING AS BUILDING.EXISTING BUILDING CORE 6. HELD VERIFY ALL FNAC,FAN CONTROL,FIRE/SMOKE DAMPERS AND DUCT DETECTORS LOCATIONS <br /> 1-WIRE MANUFACTURER IS FOR REFERENCE PURPOSE ONLY.WHEN USING OTHER MANUFACTURE,ENSURE PROPER CROSS REFERENCE AND SHELL FIRE ALARM SCOPES WERE COVERED UNDER PERMIT FA2209-003. WITH MECHANICAL CONTRACTOR <br /> DESIGN SCOPE IS FOR SOUTH FORK BAKERY TI ONLY.SHADED AREA IS NOT 7. FACP SHALL NOT BE ENERG17ED WITHOUT THE PRESENCE OF FIG FIRE TECHNICIANS. <br /> 2.FPLP CAN BED INMOST ALL APPLICATIONS WITH THE EXCLUSION OF WET AND CIRCUIT INTEGRITY REQUIREMENTS INCLUDED IN THIS PERMIT SCOPE OF WORK- 8. NO TAPPING OF SIGNAHNG OR INITIATING ZONE CIRCUITS ARE ALLOWED. T-TAPPING OF STYLE 4 <br /> 3.INSTALL WIRING PER NEC.USE CABLE TYPE CONSISTENT WITH NEC REQUIREMENTS,IE:PLENUM,RISER,UNDERGROUND,ETC, 2. ETG IS TO PROVIDE DESIGN&PROGRAMMING.AND INSTALLATIONS ALL TI ADDRESSABLE CIRCUITS IS ALLOWED PROVIDING A SPLICE IS PROFESSIONALLY INSTALLED, <br /> DEVICES AND TRIMS. POLARITY IS OBSERVED AND SHIELDS ARE CONTINUOUS AND FREE OF GROUNDS. SHIELDS MUST <br /> 3. BUILDING WILL BE EVACUATED ON GENERAL ALARM.ALL EXISTING FIRE BE TERMINATED AT FACP ONLY. <br /> C ALARM SEQUENCE OF OPERATIONS TO REMAIN THE SAME. 8.1. CABLE SHIELDS SHALL BE SPLICED TOGETHER AT EVERY JUNCTION BETWEEN THE FACP C <br /> 4. ALL EXISTING DEVICES ARE SHOWN IN LIGHTER SHADE OR ORANGE COLOR AND THE UST DEVICE ON EACH CABLE RUN. SHIELDS AND OTHER FIRE ALARM <br /> EXISTING DEVICES TO REMAIN THE SAME UNLESS OTHERWISE NOTED. CONDUCTORS(EXCEPT POWER GROUNDS)SHALL BE INSULATED AND COMPLETELY FREE <br /> FROM CONDUIT OR EARTH GROUNDS. SHIELDS WILL BE TIES TO GROUND ONLY AT THE <br /> FACP BY THE ETG FIRE FIELD TECHNICIAN. <br /> 9. THE SYSTEM SHALL BE MONITORED BY A U.L.LISTED MONITORING STATION BEFORE AHJ TEST. <br /> 10. AS-BUILTS ARE REQUIRED AT TIME OF ALL ACCEPTANCE. ETG FIRE REQUIRED ELECTRICAL RED <br /> LINES WITHIN 2 WEEKS PRIOR TO AHJ TESTS. <br /> „ 10.1. EACH CIRCUIT(SLC,HAD OR POWER)MUST BE CLEARLY IDENTIFIED WITH A DISTINCT <br /> N COLOR <br /> _ S AD A 10.2. EACH NA CIRCUIT MUST BE CLEARLY MARKED AS TO WHICH DEVICES ARE ON EACH <br /> NO P IT OP CD I CIRCUIT AND IN THE ORDER THE DEVICES ARE WIRED TO COMPLETE THE CIRCUIT. <br /> D S I T G O R XI - <br /> AL <br /> 6M A r <br /> & IC F NI SHEET SCHEDULE: <br /> PAGE# SHEET# DESCRIPTION <br /> 06-1 = H H T N P LL 0 x D4® 15CD 1 FAS-1.00 PROJECT&DESIGN INFO. <br /> TI S77V 2x PT AC L IG LO _ O 2 FAS-1.01 SYSTEM CALCULATIONS <br /> ' OMPAUL O C <br /> -End of List- <br /> SERVK q 0 <br /> YAR _ LNG Au & WA�.STAG TO NEW RESTAOOM <br /> S N ISTR U IZE EXISTING B KBOX <br /> D D <br /> STOWV O 7 ERV E E 7 CD <br /> A D v IBu #z e PROJECT SITE <br /> � z- '10 <br /> - TI XI C I E S S S <br /> I IOC 7� SCD C <br /> Everett Fire Dept.Notes: .f —an <br /> 106- 95CD <br /> (NFPA 72) <br /> an z EVERETT r 1�.,.. ... D <br /> •See Attached Fife Alarm System i - � 75 O CE AN ATF TSTTNST oRT1 T. ® ® Even°nl'Acceptance Test Checklist. i - -- 7� L NI 3 <br /> 15CD <br /> •24 hour Battery Test-At the time of the C C <br /> inspection/test provide proof verifying that the I I P L <br /> panel has been operating on secondary :El - SPA 0 75 <br /> power(battery)for 24 hours.No other I I _ 1 — s nm..�",•,,. <br /> i problems shall be indicated on the panel. A1JX C <br /> I❑ LTD O N <br /> p-NFPA 72 Report-NFPA 72 Record of I PT _ - I <br /> Completion(not req'd for Now/tamper Li <br /> . I <br /> 0 <br /> systems). r '❑ I �Ow <br /> v° <br /> E <br /> EVERETT <br /> Everett Fire Dept.Permit Review <br /> Status:Approved O ❑ DINING COVERED e.,ar.I mJ <br /> ❑ w'�w'® .w'�w'® ® ® SID K o ,nee <br /> Reviewed By:KBrown ® ® ®�® ❑ ❑ � ❑ ❑ uxbl1A ® ® ®,O5 <br /> 06/07/2023 11:33:47 <br /> ❑ _ PATIO <br /> 7 Li Permit#: FA2306-011 ---- -----�-�--DINING -------�------Site Address: 1410 <br /> ETG-FIRE <br /> Seiner Or STE 103 ❑ o <br /> Applicant: ETG-FIRE LLC I I I I I <br /> Application Date:South/Fork o SITE MAP U <br /> Description: South Fork T.I.at Port of Everett � � ❑ 2 NOT TO SCALE <br /> Review Status: 1st Review by City&Peer Reviewers <br /> Review Date: 06/07/2023 <br /> By DATE: DESCRIPTION: DRAWN BY:APPROVE BY:CLIENT: ' A8 FLOOR PLAN Aw BJCP �O5/15/2023 <br /> N.I.C.E.T. CERTIFICATION SCALE: � SOUTH FORK BAKING COMPANY TENANT IMPROVEMENTS <br /> 0 05/15/2023 SUBMITTAL DRAWI„Bs JCP MS 16 8 6 4 2 D / 1 \ E T G F. R E SSE°„� �iE PORT OF EVERETT WPC-FISHERMAN'S HARBOR <br /> F STATEMENT 11 PI PI SCALE;e'=1' F <br /> THESE FIRE ALARM DRAWINGS HAVE COMMERCIAL DEVELOPMENT-PARCEL A8 <br /> BEEN REVIEWED BY: SPECIAL HAZARDS FIRE PROTECTION 7 E„ °OS/15/2023 <br /> MIKE SEREED 3702 W.VALLEY Hwy.N.SUITE 200 ,ELT E„„I�BB. E. FIRE ALARM SYSTEM TENANT IMPROVEMENT <br /> FIRE PROTECTION ENGINEERING AUBURN,WA 98001 EET. 4 TECHNOLOGY THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION of LARAMIE AUSTIN•CHEYENNE•DENVER•PASADENA• eT S w. e. scA� FIRE ALARMSYSTEM T.I. FAS-I.00 <br /> FIRE PROTECTION AND ALL RIGHTS ARE EXPRESSLY RESERVED. THIS DRAWING IS aBNSevIe AS SHOWN PROJECT 8 DESIGN INFO. <br /> FIRE ALARM SYSTEMS-LEVEL III SALT LAKE•SEATTLE•SPOKANE <br /> NCET CERTIFICATION�101688 NOT TO BE USED FOR ANY OTHER PURPOSE NOR COPIED IN WHOLE OR PART NOR ExT. E. <br /> ITS DESIGN FEATURES USED IN OTHER PRODUCTS WITHOUT LARAMIE FIRE (206)557-3660 WWW.ETGFIRE.COM PROJECT#: 30230023 <br /> CERTIFICATION EXPIRES-1110112024 PR E N WRITTEN N EN. <br /> I 2 3 4 5 6 7 8 9 <br />