My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1410 SEINER DR 2023 SOUTH FORK BAKING COMPANY Plans 2025-07-02 (2)
>
Address Records
>
SEINER DR
>
1410
>
SOUTH FORK BAKING COMPANY
>
Plans
>
1410 SEINER DR 2023 SOUTH FORK BAKING COMPANY Plans 2025-07-02 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/26/2025 10:42:10 AM
Creation date
6/26/2025 10:42:04 AM
Metadata
Fields
Template:
Address Document
Street Name
SEINER DR
Street Number
1410
Tenant Name
SOUTH FORK BAKING COMPANY
Permit
FA2306-011
Year
2023
Notes
SOUTH FORK T.I. AT PORT OF EVERETT PARCEL A8
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I 2 3 4 5 6 7 8 9 <br /> SOUTH FORK BAKERY TENANT IMPROVEMENT <br /> A PORT OF EVERETT WPC - FISHERMAN'S HARBOR A <br /> COMMERCIAL DEVELOPMENT - PARCEL A8 <br /> FIRE ALARM SYSTEM TENANT IMPROVEMENT <br /> B B <br /> FACP Battery Load&Back-up Calculation Fire Alarm Control Panel NAC Circuit Load,Voltage Drop Calculations FACP <br /> Control Panel: Fire Alarm Control Panel APB Nam: FACP Circuit ldenffers: <br /> Locator. Electrical Rom Localm: ELECTRICAL ROOM Sandby: Aarm Oupaut#1 OulI Auz <br /> FACP Type. NFW-50(FACP) Each Each Toml Total P.S.Type: NFW50(FACP) 0.1410 0.4570 NAC Sync NAC Sync Power <br /> Line# Oty. Part#. Descriptions. Standby Aarm Standby Alarm Part#: Descriptor: N1 N2 Total Cy <br /> 1 1 NFW-SOX FACP 0.1410 0.4570 0.1410 0.4570 P2VVL WallHorn wl Strobe set at 15od 0.0000 0.0830 2 2 <br /> 2 1 FCM-1 CONTROL MODULE 0.OD04 0.0000 0.0004 0.0000 P2VVL Wal Hom wt Strobe selat75od 0.0B00 0.1560 3 3 <br /> 3 1 NP-200 SMOKE DETECTOR 0.0DD3 0,0000 0.0003 0,0000 p2VVL Wall Horn wl Strobe setet95od 0.0000 0.1770 1 1 <br /> 4 1 NOT-BG12LX P[ULL STATION 0.OD03 0.0000 0.0003 0.0000 SWL Well Strobe setatl5cd 0.0000 0.0600 5 5 <br /> 5 3 NDM-Too <br /> DUAL MONITOR MODULE 0.0DD8 0,0000 0.0024 0.0000 Sm Wall Strobe setat75cd NNW 0.1360 2 2 <br /> 6 1 P2VVL 15CDHORN STROBE 0.ODDO 0.0830 0.0000 0.0830 SVJL Wall Strobe setat110cd 0.0000 0.1790 0 0 <br /> 7 1 P2VVL 7,CDHORN STROBE 0.ODDO 0.1560 0.0000 0.1560 P2RK Well Hornwl Strobe setat75od,WP 0.0000 0.1680 1 1 <br /> 8 1 P2VVL 95CD HORN STROBE O.ODDO 0.1770 0.0000 0,1770 #Devices per Circuit 13 1 0 0 0 14 <br /> 9 4 SVVL 15CD STROBE 0.0DD0 0.0600 0.0000 0.2400 <br /> 10 1 Syk 75CD STROBE O.ODDO 0.1360 0.0000 0,1360 Total Standby Chou <br /> Calculated Amos(3): 0.000 0.000 0.000 0.000 0.0000 0.1410 <br /> 11 0 SVVL 110CD STROBE 0.0000 0.1790 0.0000 0.0000 Total Alarm Circuit Calculated Amos(1): 1.383 0.168 0.000 0.000 0.0000 0.4770 <br /> 12 1 P2RK OUTDOOR HORN STROBE 0.ODDO 0.1680 0.0000 0.1680 Wire Gauge Used(awg): 16AWG 16ANG 16AWG 16AVVG 14AWG Total <br /> 13 1 PDC1024 10.SELL O.0DD0 0.0200 0.0000 0.0200 Circuit Lenglt(Iq: 390 50 Anps <br /> 14 1 N-ANN-80 REMOTE ANNUNCIATOR 0.0370 0.0400 0.0370 0.0400 Es6aetad Voltage Drop(do): 4.42 0,07 0.00 0.00 000 Required <br /> 0,0000 0,0000 Eslmead EOL Voltage(do): 19.58 23.93 24.00 24.00 24.00 1.551 <br /> C SOUTH FORK BAKERY T.I. 0.0000 0.0000 Calculated Voltage Drop%: 18.4% 0.3% 0.0% 0A% 0.0% C <br /> 1 1 P2WL 15CD HORN STROBE 0.0DD0 0,0830 0.0000 0,0830 <br /> 2 2 P2WL !CD <br /> HORN STROBE 0.0DD0 0,1560 0.0000 0.3120 1)Current Draw Measurementbased on:UL1971,16-33V,DC,High III,&Temporal Fallen <br /> 3 1 SWL 15CD STROBE 0.0DD0 0.0600 0.0000 0.0600 2)Some OutloorNrP Devices have lie wire Measured Current Draw as the Indoor Devices and nay not III separately above. <br /> 4 1 EVIL 175CD STROBE 0.0DDD 0,1360 0.0000 0,1360 <br /> 0.0000 0.0000 <br /> 0.0000 0.0000 <br /> Total Current Drawl 0.1814 2.0680 <br /> BATTERY LOAD CALC for Fire Alarm Control PaneIFACP Max P.S.RaI 2.700 Total Arms Required: 2.068 %Used: 77a/o <br /> Hours Standby 24 Total Standby Current 0.1814 Total Amp Hours Required(AI 4.4 <br /> Minules Aarm 5 Total Alarm Current 2.0680 Total Anp Minutaa Required(AH): 0.2 <br /> Backup Generator? No Minimun Baltary Size Needed(Al <br /> ): 4.5 <br /> Voice Evacucalon? No Spare Circuit Capacity: 20% Spare Beltary Capedy Required: 0.9 <br /> Military? No Spare Salary Load Factor: 20% Actoal Batery Size Required(AH): 5.4 <br /> MAXIMUM CHARGER CAPACITY IS: 18Ai Exising Bataries Supplied:= 18.0 <br /> NOTE:SHADED DEVICES ARE EXISTING SHELL&CORE DEVICES. <br /> D D <br /> E E <br /> R <br /> DESCRIPTION: DRAWN BY:APPROVE BY:CLIENT: AIFT CRTFICATION p eJCP a05/15/2023 SOUTH FORK BAKING COMPANY TENANT IMPROVEMENTS <br /> TTAL Daawlnes JCP MS IV STATEMENT lil IV E T G F: R E SSE„a� 1 <br /> PORT OF EVERETT WPC-FISHERMAN'S HARBOR <br /> F THESE FIRE ALARM BRaMNcs HAVE SPECIAL HAZARDS FIRE PROTECTION ,E T" COMMERCIAL DEVELOPMENT-PARCEL A8 F <br /> BEEN REVIEWED BY: �o JCP Ex a05/I5/2023 <br /> MIKE REIEWED 5702 W.VALLEY Hwy.N.SUITE 200 ,LET a„�I„eea. e. FIRE ALARM SYSTEM TENANT IMPROVEMENT <br /> FIRE PROTECTION ENGINEERING AUBURN,WA 98001 aALE_ EET. <br /> TECHNOLOGY THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OFLARAMIE AUSTIN•CHEYENNE•DENVER•PASADENA• e* rex w. e_ FIRE ALARMSYBTEMT.I. FAS-1.01 <br /> FIRE ALARM SYSTEMS-LEVELIII FIRE PROTECTION AND ALL RIGHTS ARE EKPRESSLY RESERVED. THIS DRAWING IS SALT LAKE•SEATTLE•SPOKANE reI"lSEV1E ASSHOWN SYSTEM CALCULATIONS <br /> NICET CERTIFICATION§101668 NOT TO BE USED FOR ANY OTHER PURPOSE NOR COPIED IN WHOLE OR PART NOR ExT. E. <br /> ITS DESIGN FEATURES USED IN OTHER PRODUCTS WITHOUT LARAMIE FIRE (206)557-3660 WWW.ETGFIRE.COM PROJECT#: 30230023 <br /> CER¶NCA¶BN EKpIRE$-1110111024 PROTECTION'SWRITTEN N WITHOUT <br /> I 2 3 4 5 6 7 8 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.