Laserfiche WebLink
8.0 TESTING RESULTS AND INSTRUMENTS <br /> 8.1 Field Testing <br /> The following field-testing was completed with the summary results as <br /> indicated. Please refer to the Product Evaluation Data Sheet in Appendix <br /> B in this report for complete details on the specific tests completed. <br /> 8.1.1 Operation of Scanners, E Stops and Door Interlocks <br /> Each switch provided on the equipment listed in Section 5.0 was <br /> operated individually while the machine was operating. Actuation <br /> of each Switch was verified to properly stop the operation of the <br /> equipment. <br /> 8.1.2 Bonding Test <br /> The equipment bonding was verified as being properly installed. <br /> The resistance was measured from the main equipment grounding <br /> terminal to all applicable exposed metal structures or surfaces and <br /> installed equipment ground points. The maximum resistance <br /> permitted is 0.1 Ohm. The test results indicated satisfactory <br /> bonding with all resistance measures below 0.1 Ohm. <br /> 8.2 Test Equipment <br /> All equipment has been calibrated to NIST reference standards. <br /> Certificates of calibration are available upon request. <br /> Test Equipment Model eti Asset Calibration <br /> No. Date <br /> Biddle AC Hipot 3KV 670-00431 11/30/2022 <br /> Megger KVDC S1-568 2019- 11/30/2022 <br /> 002056 <br /> Fluke AC Current Probe i200 670-01378 11/30/2022 <br /> Fluke AC/DC Current Probe 11010 59317027 11/30/2022 <br /> IR Camera VT04A 670-01400 11/30/2022 <br /> ACME DLRO 6250 522- 11/30/2022 <br /> 150083 <br /> Reference No.: 1107995 Page 7 <br />