Laserfiche WebLink
Install Stabilizing <br /> Systems <br /> Figures 54 <br /> I 1 <br /> FLOOR <br /> i — <br /> 6"MAX INSET , - --NEAR I-BEAM -- --- -a J-I- FAR I-BEAM <br /> in , / ....... -- <br /> 1 FOR NEAR <br /> ce A NEAR BEAM - --, FAR BEAM FRAME TIEDOWN <br /> ? BEAM TIEDOWN / FRAME ' INSTALLED WHEN NEAR BEAM <br /> ., 10"MIN INSET TIEDOWN TIEDOWN EXCEEDS 60° <br /> u- FOR FAR BEAM fAs 60°__ -TIEDOWN - - ,- ,MAX. GROUND LEVEL <br /> --1. <br /> 11F-STABILIZEFt PLATE <br /> i <br /> 4—GROUND ANCHOR <br /> 3,3 Wind Zone 1 Frame Tiedown:When the angle of the near beam frame tiedown strap exceeds 60 degrees the far beam frame <br /> tiedown strap is [nstalled .n addition to the near beam strap <br /> J/ <br /> - VERTICAL <br /> JIEDOWN , <br /> , <br /> \--FLOOR TO ANCHOR STRAP - • ,c1,..luC.L.1 . '; - <br /> = : <br /> AND BUCKLE NOT 7-- t ,--4.1,‘,.-1 .14`.. Itildet <br /> SIDEWALL -------' PROVIDED ; . "k5.,„•,.)4,/,-vgC r\...• .::•,.' <br /> VERTICAL vyi.E.cv.. <br /> TIEDOWN- -•,..(512,.:-s-f,-,- . •.%. c'•!..7.1,,,:z <br /> i-- FLOOR ,,,•-4Z-..-:y 1 U ';'...--V, i <br /> i ,-- _- /..1 . • -.,%c•t-7\\\ i <br /> Lu <br /> NEAR I-BEAM TZFAR I-BEAM 6"MAX INSET -- ---- ; <br /> r <br /> iI FOR NEAR , <br /> •• NEAR BEAM -• FAR BEAM FRAME TIEDOWN INSTALLED IN PLACE OF NEAR <br /> § BEAM TIEDOWN \ FRAME FRAME BEAM TIEDOWN WHEN NEAR BEAM FRAME TIEDOWN <br /> 10 MIN INSET 1 \ <br /> FOR FAR BEAM <br /> TIEDOWN EXCEEDS 60°.FAR BEAM FRAME TIEDOWN WILL NOT BE <br /> rt: 1 60°- <br /> r INSTALLED IN ADDITION TO THE NEAR BEAM FRAME TIEDOWN. <br /> TIEDOWN <br /> —STABILIZER PLATE \--GROUND LEVEL <br /> GROUND ANCHOR <br /> NOTE:WHEN THE HOME IS INSTALLED SO THAT THE FRAME <br /> TIEDOWN WILL BE CONNECTED TO THE FARTHEST I-BEAM AS <br /> *FLOOR JOIST AND I-BEAM SHOWN INVERTED. SHOWN ABOVE,A 5/16'X 2 1/2"(MIN)FULLY THREADED LAG SCREW <br /> MUST BE INSTALLED ON THE INSIDE FLANGE OF THIS BEAM ON <br /> INSIDE — - OUTSIDE EACH JOIST WHICH HAS A LAG INSTALLED ON THE OUTSIDE FLANGE <br /> EDGE OF , EDGE OF (SEE DETAIL BELOW). <br /> MAIN I-BEAM --- MAIN <br /> I-BEAM , -,, <br /> 4C-,> \. <-6••••• <%s `....-- <br /> -, <br /> BEAM SECURED TO FLOOR FLOOR <br /> OPTION#1 OPTION#2 OPTION#3 OPTION#4 OPTION#5 <br /> , . <br /> OPTION 1:3/32'X 1"X 1/2"LAG CLIP(MAY BE FLAT OR OFFSET) <br /> - <br /> JOIST WITH ONE OF THE JOIST OPTION 2:2"X 13GA.ROUND FLAT WASHER <br /> OPTIONS LISTED OR WITH <br /> OPTION 3: 13GA.3"X 2 3/6"(MIN)SLOT(ED LAG CLIP <br /> I <br /> 1 LAG SCREW THROUGH A 3/8" OPTION 4:11GA.3"X 2'(MIN)SLOTTED LAG CLIP <br /> i <br /> HOLE IN I-BEAM FLANGE. <br /> OPTION 5:11GA.2 3/4'X 1 1/2"(MIN)SELF-ALIGNING SLOTTED LAG CLIP <br /> --I <br /> Wind Zone 2 and 3 Near I-Beam and Far I-Beam Frame Tiedown <br /> When the angle of the near beam frame tiedown strap exceeds 60 degrees the tiedown strap must be nstalled to the far beam <br /> frame. <br />