My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9824 HOLLY DR 2022 Plans 2025-07-02
>
Address Records
>
HOLLY DR
>
9824
>
Plans
>
9824 HOLLY DR 2022 Plans 2025-07-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2025 8:54:15 AM
Creation date
7/2/2025 8:52:57 AM
Metadata
Fields
Template:
Address Document
Street Name
HOLLY DR
Street Number
9824
Permit
B2210-049
Year
2022
Notes
NEW MANUFACTURED HOME AS DADU
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Install Stabilizing <br /> Systems <br /> Figures 54 <br /> I 1 <br /> FLOOR <br /> i — <br /> 6"MAX INSET , - --NEAR I-BEAM -- --- -a J-I- FAR I-BEAM <br /> in , / ....... -- <br /> 1 FOR NEAR <br /> ce A NEAR BEAM - --, FAR BEAM FRAME TIEDOWN <br /> ? BEAM TIEDOWN / FRAME ' INSTALLED WHEN NEAR BEAM <br /> ., 10"MIN INSET TIEDOWN TIEDOWN EXCEEDS 60° <br /> u- FOR FAR BEAM fAs 60°__ -TIEDOWN - - ,- ,MAX. GROUND LEVEL <br /> --1. <br /> 11F-STABILIZEFt PLATE <br /> i <br /> 4—GROUND ANCHOR <br /> 3,3 Wind Zone 1 Frame Tiedown:When the angle of the near beam frame tiedown strap exceeds 60 degrees the far beam frame <br /> tiedown strap is [nstalled .n addition to the near beam strap <br /> J/ <br /> - VERTICAL <br /> JIEDOWN , <br /> , <br /> \--FLOOR TO ANCHOR STRAP - • ,c1,..luC.L.1 . '; - <br /> = : <br /> AND BUCKLE NOT 7-- t ,--4.1,‘,.-1 .14`.. Itildet <br /> SIDEWALL -------' PROVIDED ; . "k5.,„•,.)4,/,-vgC r\...• .::•,.' <br /> VERTICAL vyi.E.cv.. <br /> TIEDOWN- -•,..(512,.:-s-f,-,- . •.%. c'•!..7.1,,,:z <br /> i-- FLOOR ,,,•-4Z-..-:y 1 U ';'...--V, i <br /> i ,-- _- /..1 . • -.,%c•t-7\\\ i <br /> Lu <br /> NEAR I-BEAM TZFAR I-BEAM 6"MAX INSET -- ---- ; <br /> r <br /> iI FOR NEAR , <br /> •• NEAR BEAM -• FAR BEAM FRAME TIEDOWN INSTALLED IN PLACE OF NEAR <br /> § BEAM TIEDOWN \ FRAME FRAME BEAM TIEDOWN WHEN NEAR BEAM FRAME TIEDOWN <br /> 10 MIN INSET 1 \ <br /> FOR FAR BEAM <br /> TIEDOWN EXCEEDS 60°.FAR BEAM FRAME TIEDOWN WILL NOT BE <br /> rt: 1 60°- <br /> r INSTALLED IN ADDITION TO THE NEAR BEAM FRAME TIEDOWN. <br /> TIEDOWN <br /> —STABILIZER PLATE \--GROUND LEVEL <br /> GROUND ANCHOR <br /> NOTE:WHEN THE HOME IS INSTALLED SO THAT THE FRAME <br /> TIEDOWN WILL BE CONNECTED TO THE FARTHEST I-BEAM AS <br /> *FLOOR JOIST AND I-BEAM SHOWN INVERTED. SHOWN ABOVE,A 5/16'X 2 1/2"(MIN)FULLY THREADED LAG SCREW <br /> MUST BE INSTALLED ON THE INSIDE FLANGE OF THIS BEAM ON <br /> INSIDE — - OUTSIDE EACH JOIST WHICH HAS A LAG INSTALLED ON THE OUTSIDE FLANGE <br /> EDGE OF , EDGE OF (SEE DETAIL BELOW). <br /> MAIN I-BEAM --- MAIN <br /> I-BEAM , -,, <br /> 4C-,> \. <-6••••• <%s `....-- <br /> -, <br /> BEAM SECURED TO FLOOR FLOOR <br /> OPTION#1 OPTION#2 OPTION#3 OPTION#4 OPTION#5 <br /> , . <br /> OPTION 1:3/32'X 1"X 1/2"LAG CLIP(MAY BE FLAT OR OFFSET) <br /> - <br /> JOIST WITH ONE OF THE JOIST OPTION 2:2"X 13GA.ROUND FLAT WASHER <br /> OPTIONS LISTED OR WITH <br /> OPTION 3: 13GA.3"X 2 3/6"(MIN)SLOT(ED LAG CLIP <br /> I <br /> 1 LAG SCREW THROUGH A 3/8" OPTION 4:11GA.3"X 2'(MIN)SLOTTED LAG CLIP <br /> i <br /> HOLE IN I-BEAM FLANGE. <br /> OPTION 5:11GA.2 3/4'X 1 1/2"(MIN)SELF-ALIGNING SLOTTED LAG CLIP <br /> --I <br /> Wind Zone 2 and 3 Near I-Beam and Far I-Beam Frame Tiedown <br /> When the angle of the near beam frame tiedown strap exceeds 60 degrees the tiedown strap must be nstalled to the far beam <br /> frame. <br />
The URL can be used to link to this page
Your browser does not support the video tag.