Install Stabilizing <br /> Systems <br /> FRAME TIEDOWN SPACING <br /> Wind Zone 1 Tiedown S>acinc: f'a e No <br /> Table 1F) Single Section Roof Pitch 4.36/12 Max. 78 <br /> Table 18a Multi Section Roof Pitch 4.36/12 Max. 78 <br /> Table 18b Triple Secton Roof Pitch 4.36/12 Max. 79 <br /> Wind/one I Iunluwn SpaTeig- h Witch truss <br /> table 18c Multi Section Roof Pitch 5/12 Max 79 <br /> Table 18d Tnple Section Roof Pitch 5/12 Max. 80 <br /> fable 18e Multi Section Roof Pitch 6/12 Max. 80 <br /> Table 181 Triple Section Roof Pitch 6/12 Max. 80 <br /> table 18c Multi Section Roof Pitch 7/12 Max. 81 <br /> Table 1811 Tn•le Section Roof Pitch 7/12 Max. 81 <br /> Wind Zone 2 Near 113eam Tiedown Spacing <br /> I able 19 Single Section Roof Pitch 4.36/12 Max. 82 <br /> Table 19a Multi Section Roof Pitch 4.36/12 Max. 82 <br /> Wmd Zone 2 Far I-Ream fiednwn Spacing <br /> fable 19b Single Section Roof Pitch 4.36/12 Max. 83 <br /> Table 19c Multi Section Roof Pitch 4 36/12 Max. 83 <br /> Wind Zone 2 Ncai I pecan i redown SPiicang--I In h Pitch lams <br /> Table 19d Multi Section Roof Pitch 5/12 Max. 84 <br /> Wind Zone 2 Far IT3eam tiedown spacing -High Pitch Truss <br /> fable 19e Multi Section Roof Pitch 5/12 Max. 84 <br /> Table 191 Multi Section Roof Pitch 6/12 Max 84 <br /> law 19cl Multi Section Roof Pitch 7/12 Max. 85 <br /> Wind Zone 3 Near I-I team 1 redown Specint. <br /> Table 20 Single Section Roof Pitch 4,36/12 Max 85 <br /> I able 20a Multi Section Roof Pitch 4.36/12 Max_ 85 <br /> Wind Zone 3 Far I Hearn Tiedown Spacing <br /> Table 20b Single Section Roof Pitch 4.36/12 Max 86 <br /> I able 20c Multi Section Roof Pitch 4.36/12 Max. 86 <br /> TIEDOWN LIMITATIONS AND SPECIFICATIONS <br /> • Anchors shah be certified for site conditions including soil type for design capacity of 3150 lbs. with resistant pull load ap- <br /> plied at a minimum 30 degree angle from horizontal. <br /> • Anchors may be inset from the edge of the sidewall 6" maximum for a near beam set and 10" minimum for a far beam set, <br /> • The floor widths listed in the following charts include the following ranges of widths' <br /> • 10 Wide= 120" <br /> • 12Wide= 136"-144" <br /> • 14 Wide= 156"-168" <br /> • 16 Wide= 180"— 190' <br /> • 18Wide =204"-210" <br /> • 20 Wide= 120" <br /> • 24 Wide= 136"— 144" <br /> • 28 Wide= 156"—168' <br /> • 32 Wide= 178"— 186" <br /> • The maximum overhang allowed for a single section is 6' and the maximum overhang allowed for a multi section is 24' <br /> • The following frame tiedown charts list the maximum floor height measured from the top of the grade to the connection <br /> point of the tiedown strap to the I-beam. Cross reference the maximum allowable pier height(Table 9 and Table 12)with <br /> maximum allowable floor height listed in the frame tiedown charts If maximum height listed in frame tiedown charts is ex- <br /> ceeded then designs must be provided by a registered professional engineer or registered architect. <br /> • Contact the manufacturer if the home you are attempting to set has a floor width, I-beam spacing,wall height or <br /> roof pitch that is not shown in any of the following charts(or listed as NA). <br /> • The""" listed after any tiedown spacing signifies that a 60 degree angle has been exceeded and an additional strap must <br /> be added to the far beam. <br /> • Verify that the anchor spacing required in the following charts is greater than the minimum allowable spacing of the type of <br /> anchor installed Verify that sidewall vertical tiedown bracket spacing meets the requirements for Wind Zone 2&3 homes. <br /> Bracket spacing may be increased or additional brackets may be added as required <br />