8102 EVERGREEN WAY 2022 EVERETT 4 CORNERS - BLDG C Plans 2025-07-02
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG C
>
Plans
>
8102 EVERGREEN WAY 2022 EVERETT 4 CORNERS - BLDG C Plans 2025-07-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2025 9:46:17 AM
Creation date
7/2/2025 9:45:24 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG C
Permit
M2206-007
Year
2022
Notes
BUILDING C UNIT VENTILATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PARKING NOTES <br /> CI) C.g C h en C.n <br /> • 1. SEE SHEET AOOI FOR REQUIRED �OHNSO�RAUND�NE <br /> PARKING CALCULATIONS. <br /> I I I I <br /> 2. PARKING STALL SIZE 15200 52nd Ave.SouthSuite 300 <br /> E <br /> =8'-a'X i6'-a'MIN. Seattle,WA 98168 <br /> 2 ' (20 FT.MIN DRIVE AISLE) Ptrone 206.786 8300 <br /> ww <br /> A430 -_-_� L -_ �_-_-_r___-_-_-____ - -8'�"X 18'-6" ARCHITEICTUREnd.com <br /> [i (24 FT.MIN.DRIVE AISLE) INTERIOR DESIGN <br /> GE <br /> L Allyn.. <br /> 'I�' ' 3. ACCESSIBLE STALLS: C) JeffreyA wmlams. <br /> ' A333 HC STANDARD:S-0"MIN WIDTH W/5'-0" <br /> ACCESS AISLE ALONG ENTIRE <br /> I LENGTH OF STALL <br /> __ SEE DETAILS 19/A021 FOR SIGNAGE. <br /> 0 'I s rT 1 I \ 9 4. COLUMNS ENCROACH 8"INTO <br /> u. REQUIRED STALL WIDTH MAX. <br /> w , 5. ®FUTURE DUAL ELECTRICAL VEHICLE <br /> CHARGING INFRASTRUCTURE <br /> • U• <br /> SEE SITE PLAN A020 FOR <br /> ro w • <br /> „ADDITION I1FORMATIQN, • " <br /> I IA <br /> 1e SHEET NOTES 6556 <br /> - - - - N I RARCHITEGISTEECTRED <br /> I 1. PODIUM CONSTRUCTION TYPE IA , <br /> 2. ALL LEVELS FULLY SPRINKLERED PER <br /> WILLIAff <br /> C.10 - �T e 1 \ \_C. <br /> _e - L T - - - - e- - \ \O IBC 903.3.1.1(NFPA 13). FFRE7 ARTIitS NGTON <br /> STATE OF wpSNiNGiON <br /> - I REFERBL SHEETSC303 FOR WALFIRE STAMP <br /> `J 18 r , -A• r `/ 3 ASSEMBLY KEY PLAN W/WALL TYPE <br /> .u._- TAGS 8 LOCATIONS.REFER TO <br /> SHEET SERIES A040 FOR ASSEMBLY <br /> LL DETAILS <br /> L -J ❑ m 4 1 - -1 INDICATES <br /> z 8 <br /> W CONCRETE WALL OR COLUMN PER <br /> rc <br /> J STRUCTURAL. B•E <br /> _ c _. I I e o '.� <br /> 6 w EXIT STAIR ENCLOSURES IN TYPE 1A <br /> C.f w r CONSTRUCTION SHALL BE 3-HOUR <br /> r RATED <br /> 4 g <br /> ALL VERTICAL SHAFTS SHALL BE 2- - <br /> I I <br /> 8. HOUR RATED PER IBC 713.4. <br /> _ 6 r - 73-4"_-L 6 9'1 I y-' 7. O SDOORA -SEE SCHEDULE <br /> A502 A432 1- , <br /> _ I _ _ <br /> 21 2,• <br /> �1_� _ -'� _ DOM.PUMA' _ I4QI?DI - �_ _ \ -� - \ C.171 8. REFER TO SHEET SERIES <br /> UNIT PLAN DOOR 8 WINDOW�FOR <br /> �/ b I ON I �-� II `� SCHEDULE. <br /> _ 3 2 ', 7A502 P <br /> _ \ -- - I' 9. REFER TO SHEET SERIES A100 G <br /> a I © 1 FOR ENLARGED UNIT PLANS. = <br /> 151� 1 z <br /> FI)a m--1 .. r e <br /> - 17 m E. �" 007 I1DI 10 EYi t0 ONFER TO SHEET CSOOSSIBILITV NOTES g <br /> \ \ Ti ____ LL II 11. PROVIDE MECHANICALLY <br /> 1 VESTIBULE co FASTENED INSULATION AT ALL <br /> /'" J 006 CEILINGS BETWEEN CONDITIONED <br /> 1.b{ , I_ _ II __I AND UNCONDITIONED SPACE, -^ <br /> / REFER TO SHEET A040 FOR <br /> , © _ 1 STAIR#3 I REQUIRED R-VALUES. <br /> \rye1Z7 L � tl 'ST-T 1- -It- <br /> ..... ��e �` W <br /> �-��,-fr�r�, ��� C.1 g;o ___ 1B I - - _E3 \ - \ C� 12. CORRIDOR VENTILATION CONCEPT <br /> i <br /> "�A4 4 /� UP MECHANICAL REFER PLANDESIGNBUILD s <br /> ,, 3/18". : a 2 _ I \/ PLANS. Q <br /> ''-'- "...-^�'`•�`�'`�'�'-'"L'-� \ �•P ----------- -�I • 13. OF.E.C. 'SLB ABC'RECESSED/FIRE <br /> KNOX BOX LOCATION, r -+ EXTINGUISHER C•:INET $ <br /> FINAL LOCATION TO BE I -J SEE DETAIL Q <br /> VERIFIED IN FIELD _ - _-- -2- o <br /> 4 A332 z s I - 1) ® i <br /> 1�JI © �¢ e -, 4. �f.E FIREFEXTNGUtSHERCABINET C `__ <br /> u LOCATE PER IBC TABLE 906.3 <br /> 1w 1B * (1)75 FT.MAX.SEPARATION P` <br /> I -',.:.-13, <br /> O <br /> _LEVEL2 � 13 • -(7 SEE DETAIL MOUNTING/NST51FOR E <br /> • _p 1 1 1 1 II 1 1 1 1 1� is-8" . v J EIGHTING/INSTALLATION t € <br /> LI I 15. 1 EXIT I SIGN PER IBC 1013. 0 Po.' <br /> e a' <br /> - C.131 \ - - :� - - -T - �B \ _ - \ C.1� 18. REFER TO DESIGN/BUILD �'W € <br /> • `/ �/ ELECTRICALPLANS. y go <br /> LL L .Q o 17. REFER TO SHEET A051 FOR d 013 $ <br /> I - r- I -n PENETRATION REQUIREMENTS IN o9 <br /> FIRE RATED CONSTRUCTION. L m w B <br /> _ -- - _ - LEVEL 19. REFERENCE BUILDING ENVELOPE0 m V w 3G <br /> -�-I /� DRAWINGS FOR ALL WATERPROOFING. V m i <br /> 'uW,w�I1 a• ;R <br /> `x III�IT=TI �IFS-Vr i ni-T�JyL-VI�'141POF_-� TI I 5 c-mm3 i <br /> m -"' "- �'- - - 19. AT DOORS INTO ELECTRICAL CONTROL L pO E w - g3'" <br /> WI "l-^✓-✓l-rYl-'Y1r'Yl^'l-r-,1-.- - = Q W U L'S' EG <br /> \ PANEL ROOMS,SIGNAGE SHALL BE <br /> ZI S(3 ELEVATION-AMAZON HUB SHED ROOF N ry PROVIDED ON THE DOOR STATING O -0_ „a <br /> ELECTRICAL ROOM' cot' <br /> O..9 m :g <br /> C J`� �'� `�`�'',`��'J`�'���"� I • 28. AT DOORS INTO FIRE PROTECTION <br /> EQUIPMENT ROOMS CONTAINING <br /> UI I - SPRINKLER RISERS,FACP.OR OTHER <br /> 81 tB I SUPPRESION CONTROL ELEMENTS. <br /> C APPROVED SIGNAGE SHALL BE <br /> E I 2a-0" PROVIDED AND READILY VISIBLE PER <br /> E 4 /\ • ¶ iB �\ IFC 509.1 <br /> I'o W23o C.14\ \ - - - -_L---4 .. J I ---� i• - \ ♦C.J KEY PLAN <br /> NP- <br /> m I 18'-1" I 29•-0" 18•_i•, Q <br /> • <br /> i m <br /> I . - AMAZON HUB LOCKE- ES-2 - _ __ �� <br /> m <br /> g ®11�eJ 18 • _- 1 1 <br /> x 1 -:---4---r-----17 0" I C•911: A431) C.m <br /> PROJECT it 1827 <br /> c - A330 DRAWN BY: AT <br /> Li; <br /> g A230A UNE OF SOFFIT ABOVE <br /> UNE OF SHED ROOF ABOVE CHECKED BY: ST <br /> • S 2a-0" <br /> M BLDG C-GARAGE <br /> SOUTH <br /> C) <br /> .IAA_-;HUB PLAN-- <br /> A230A <br /> ��AMAZON HUB PLAN BUILDING C <br /> (---1 BI DG C-GARAGE SOUTH /� \, 0 CONSTRUCTION SET <br /> MMENNIMMI <br /> n 1/8"=1-0"- --- 11 r/ 09/01/2021 <br />