Laserfiche WebLink
MINIIIMIII <br /> i PARKING NOTES <br /> 0C.h m C.n <br /> • A331 / 85' - - - / 1. SEE SHEET A001 FOR REQUIRED <br /> 18.-0" 2'-8"3'-0" PARKING CALCULATIONS <br /> 1 / 2a i JOHNSON BRAUND <br /> -/ I 2 PARKING STALL SIZE: 15200 52nd Ave South <br /> GARAGE SCREEN ) m Suite 300 <br /> Q 18 1 1B E=6-0"X 16'-0"MIN. SBatle,WA98188 <br /> 1�12' Phone 206.766.8300 <br /> ® - _ -- 1 - ----- 18 / I O (20 FT.MIN DRIVE AISLE) ,v,W,jnnnsanerzura.wm <br /> -r'---- J 11 \ ♦C.1 <br /> �w I - • - I �S =8'$"X 18'-8" ARCHITECTURE <br /> (24 FT.MIN.DRIVE AISLE) INTERIOR DESIGN <br /> - • <br /> 1 -- I� 1 _T_ _ _ _IL_ _ �.��-_ .+- Greg AIMn2. <br /> IZUP ,�3 ST-1 I - 11 I" ^ • 1 1' L� I 3. ACCESSIBLE STALLS. ® Jeffrey A wsniams. <br /> I i'-0" 18'-5" 'H <br /> • C I r - • • 18 I S STANDARD::FAQ'MIN WIDTH W/5'-0" <br /> "r to ACCESS AISLONG ENTIRE <br /> b LENGTH OF LL <br /> `r I 1 I I10I4DI SEE DETAIL /A021 FOR SIGNAGE. <br /> C.10 IA .v —_—.� <br /> KNOX BOX LOCATION, <br /> FINAL LOCATION TO BE V _ 010 L'IB J 4. COLUMNS EOACH 6"INTO <br /> VERIFIED IN FIELD VVVV \. I REQUIRED SL WIDTH MAX. <br /> C.2 \ _ n ��] \ G.2 5. ®FUTURE DULECTRICAL VEHICLE11D \ CHARGING IASTRUCTURE. <br /> nns - SEESITEPL020FOR• <br /> C ADDITI,ONALRM{TIQN, , <br /> r SHEET NOTES arse <br /> • • I REGISTERED <br /> Z RCNITECT <br /> w I w 1. PODIUM CONSTRUCTION TYPE IA <br /> w <br /> m m I b U <br /> - <br /> io <br /> 2. ALL LEVELS FULLY SPRINKLERED PER <br /> g `g (9 I N r IBC 903.3.1.1(NFPA 13). STATE Or TWASN NGTON1 <br /> • L 3 REFER TO SHEETS CSO3 FOR FIRE <br /> ASSEMBLY KEV PLAN W/WALL TYPE STAMP <br /> O I iB TAGS 8 LOCATIONS.REFER TO <br /> I SHEET SERIES A040 FOR ASSEMBLY <br /> Y <br /> I 4 DETAILS 1 INDICATES I 4 <br /> r <br /> 1 J CONCRETE WALL OR COLUMN PER <br /> \ STRUCTURAL. u 1 <br /> O I w © I 0� \ I \m C.3 5. EXIT STAIR ENCLOSURES IN TYPE 1A S= <br /> CONSTRUCTION SHALL BE 3-HOUR <br /> ro m I w 1 RATED <br /> L ® I 6 ALL VERTICAL SHAFTS SHALL BE 2- Ip 3 <br /> HOUR RATED PER IBC 713.4. <br /> 2 <br /> 7Q �- .\\•1' I to O SHEET A100 <br /> 7 1 DOOR TYPE-SEE SCHEDULE <br /> • <br /> a-r ifi <br /> P. <br /> gg B. REFER TO SHEET SERIES MOO FOR <br /> r I I —I <br /> a-Gj- 18 UNIT PLAN DOOR 8 WINDOW 5 <br /> • ® ® SCHEDULE. zqy <br /> iiiic9 d <br /> 9. REFER TO SHEET SERIES A100 <br /> I J FOR ENLARGED UNIT PLANS. = <br /> _.� 4D �+� — 4 \ L •- \ G'4 10. REFER TO ACCESSIBILITY NOTES <br /> _.KNOX BOX LOCATION, -- 1 B J I - ON SHEET CS00 y� <br /> FINAL LOCATION TO BE j ,I- II �� Iw ' , <br /> VERIFIED IN FIELD is I JVESTIBULE ( 005 I 12 I m 11. PROVIDE MECHANICALLY D <br /> El `_•,. 4D- 0 <br /> G3 — _ ••I • FASTENED INSULATION AT ALL <br /> CEIL_ C.5 - ' ° ! ... .1 a Im< - - - - " - - \ \GS ANDIUNCONDNGS DITIONEDEEN OSPACE.NEO $- <br /> j rc- <br /> +� LOCATION OF ELEVATOR REFER TO SHEET A040 FOR <br /> IyQ \ �,� I coWoELEV� I I SUMP PUMP,SEE REQUIRED R-VALUES. <br /> 7 \ ELEV-11 PLUMBING DRAWINGS <br /> L 1I I 12 CORRIDOR VENTILATION CONCEPT <br /> • <br /> SHOWN,REFER TO DESIGN/BUILD W,, <br /> _ '40'1D LOBBY MECHANICAL PLANS. o <br /> 002 <br /> Iink <br /> �_ , 13. BF E.C. 'SLB ABC'RECESSED/FIRE i <br /> ak <br /> / 5'-11' I —L,2'I _ E I a - - • _' EXTINGUISHER -INET <br /> Q ___—_—_— —_-_I _ I LEY_' 1_— �^�T_____—_ —_ SEE DETAIL: Q <br /> C.B O L. <br /> O _ IL <br /> _ i t C.B 14 .F.E. SURFACE MOUNTED'SLB ABC' 4, <br /> 'tSP"\\ FIRE EXTINGUISHER CABINET <br /> F.E.+ CO I1B © El LOCATE PER BC TABLE 906.3(1)75 FT.MAX.SEPARATION 'o 8 <br /> / 8'-8" / 8'-a' / 8-6" 3'-6"2''-5" 9'-01/2AV SEE DETAIL 3/A051 FOR E 4.2 <br /> ( dr <br /> Z MOUNTING/INSTALLATION rc _1 HEIGHT <br /> HEIGHT w <br /> 95 UNITS rO y • 15 [EXIT' SIGN PER IBC 1013 0 10 <br /> 73 STALLS I. <br /> „ <br /> J I <br /> © r r —I 1 —1 �n 16. REFER TO DESIGN/BUILD Q ?'mm <br /> __ ELECTRICAL PLANS. i €y <br /> I' g3 <br /> r L -1 17. REFER TO SHEET A051 FOR $ <br /> I PENETRATION REQUIREMENTS IN C B _o go <br /> ` FIRE RATED CONSTRUCTION. C S i _ <br /> 1 TB. REFERENCE BUILDING ENVELOPEm w z <br /> 'I�' IrJII--I. Q ,4 <br /> rci <br /> \ t A333 0 g U'�DRAWINGS FOR ALL WATERPROOFING. U y C0 5 <br /> c19. AT DOORS INTO ELECTRICAL CONTROL L o ', &w 3 3' <br /> NI I 1 PANEL ROOMS,SIGNAGE SHALL BE 3 8 3 Zs, 4 <br /> ZI O - - _ s - - ILi _. O EPLECTRICAL ROOM'OVIDED ON THE DOOR STATING 0 = § ,W,a <br /> C.9 1 � — \ C.9 m ow m € <br /> N - __ 20 AT DOORS INTO FIRE PROTECTION <br /> ly EQUIPMENT ROOMS CONTAINING <br /> Vt I I I rc l SPRINKLER RISERS,FACP,OR OTHER <br /> - B io O SUPPRESION CONTROL ELEMENTS, <br /> d m <br /> APPROVED SIGNAGE SHALL BE <br /> PROVIDED AND READILY VISIBLE PER <br /> U v Cn - IFC 509.1 <br /> KEY PLAN <br /> co 1 <br /> r <br /> 18 W <br /> 9 .3:Il . <br /> L_J J _ . • PROJECTS 1827 <br /> ✓ I I DRAWN BY: AT <br /> III <br /> • CHECKED BY. ST <br /> D f BLDG C-GARAGE <br /> U I I NORTH <br /> I <br /> 1 C 9 40® / ',BLDG C-GARAGE NORTH C.n' BUILDING C ALUCTION ON EET <br /> T <br /> s 0 09/01/2021 <br />