Laserfiche WebLink
1 2 1 3 1 4 1 5 fi 1 7 1 8 1 9 10 1 11 <br /> SUBJECT TO FIELD <br /> INSPECTION <br /> RECEPTACLE TYPES RECEPTACLES WORK DEFINITION ABBREVIATIONS PROJECT DETAILS tgb architects <br /> I TT I City of Everett Permit Services <br /> REVIEWED FOR CODE COMPLIANCE <br /> (tAC MOUNTED 3'ABOVE COUNTER BACKSPLASH 0 0 DUPLEX, 120V FLAG NOTE A,AMP AMPERE KWH KILOWATT HOUR PROJECT SCOPE: <br /> ABV ABOVE LED LIGHT EMITTING DIODE DEMOLITION AND REPLACEMENT OF EXISTING CT EQUIPMENT LOCATED IN CT <br /> By Review Discipline:Building D DEDICATED CIRCUIT 0}y DOUBLE DUPLEX, 120V AC 3"ABOVE COUNTER LS LIFE SAFETY SIMULATOR ROOM 210.38. t 425.778.1530 21911 76th Ave W.Ste 210 <br /> Reviewer:MWicklander 1# # REVISION IDENTIFICATION BACKSPLASH LTG LIGHTING f 425.774.7803 Edmonds WA 98026 <br /> Date:11/15/2024 �G GROUND FAULT CIRCUIT INTERRUPTER(GFCI) DUPLEX, 120V,CEILING MOUNTED ACH ABOVE COUNTER HEIGHT LTS LENGTH ONLY TO SCALE PROJECT ADDRESS: info@tgbarchitecls.com <br /> Review Status:Approved for Permit ®® EQUIPMENT IDENTIFICATION AFCI ARC-FAULT CIRCUIT LV LOW VOLTAGE PROVIDENCE REGIONAL CANCER PARTNERSHIP www.tgbarchitects.com <br /> DOUBLE DUPLEX, 120V,CEILING MOUNTED INTERRUPTING MAG MAGNETIC 1717 13TH ST. <br /> AFF ABOVE FINISHED FLOOR MAX MAXIMUM EVERETT,WA 98201 <br /> # AG ABOVE GRADE MCB MAIN CIRCUIT BREAKER <br /> DETAIL REFERENCE AHJ AUTHORITY HAVING MCC MOTOR CONTROL CENTER ENGINEERING CONTACT: <br /> # JURISDICTION MH MANHOLE EBD SERVICES <br /> y S AIC AMPERE INTERRUPTING MIN MINIMUM JACK GLOVER <br /> LIGHT FIXTURES CIRCUITS CAPACITY MLO MAIN LUGS ONLY 206-413-6095 EXT 9 <br /> AL ALUMINUM MM MULTIMODE JACK.GLOVER®EBD—SERVICES.COM <br /> pa LOWER-CASE LETTER DENOTES SWITCH LEG RACEWAY CONCEALED IN CEILING OR WALL SECTION REFERENCE AM AMMETER MTD MOUNTED <br /> ANSI AMERICAN NATIONAL MW MICROWAVE <br /> 0 p RECESSED,DTS EXISTING RACEWAY ### STANDARDS INSTITUTE N NEUTRAL EVIDENCE <br /> A/V AUTOMATIC T NC NORMALLY CLOSED EBD BASED <br /> 4 4 WALL—MOUNTED,LTS — RACEWAY BELOW SLAB OR UNDERGROUND N ATS AUTOMATIC TRANSFER NEC NATIONAL ELECTRICAL CODE GENERAL NOTES. oa „ <br /> DESIGN <br /> SWITCH NEMA NATIONAL ELECTRICAL e <br /> E) RACEWAY UP PROJECT NORTH REFERNCE AWG AMERICAN WIRE GAUGE MANUFACTURERS 1. ALL ELECTRICAL WORK AND MATERIALS ARE TO COMPLY WITH THE LATEST <br /> 00 00 RECESSED DOWNUGHT,DTS BAS BUILDING AUTOMATION ASSOCIATION REQUIREMENTS OF ALL APPLICABLE CITY,COUNTY,AND STATE CODES AS S E R V 1 C E S <br /> 9 RACEWAY DOWN SYSTEM NFPA NATIONAL FIRE PROTECTION WELL AS THE NATIONAL ELECTRICAL CODE AS ADOPTED AND AMENDED BY <br /> N/A EXIT SIGN,FILLED SIDE ILLUMINATE,DIRECTIONAL ASSOCIATION <br /> BKR BREAKER THE LOCAL AUTHORITY HAVING JURISDICTION. <br /> ARROWS AS INDICATED,TITS ———�] RACEWAY STUB-OUT WITH BUSHING NEW WORK CAN COMMUNITY ACCESS NIC NOT IN CONTRACT <br /> TELEVISION NO NORMALLY OPEN 2. COORDINATE EXACT LOCATIONS OF ALL ELECTRICAL DEVICES WITH <br /> Q X-RAY ON LAMP CIRCUIT CONTINUATION EXISTING CONDITIONS <br /> CO CONDUIT ONLY OCPD OVERCURRENT PROTECTIVE <br /> HOMERUN CB CIRCUIT BREAKER DEVICE <br /> FUTURE WORK CCTV CLOSED CIRCUIT TELEVISIONOPER OPERATER/OPERABLE <br /> LIGHTING CONTROLS 0 JUNCTION BOX � xxx DEMOLISH EXISTING CKT CIRCUIT OPOI OWNER PROVIDED OWNER CLG CEILING INSTALLED STANDARD MOUNTING HEIGHTS <br /> $a LOWER-CASE LETTER DENOTES CIRCUIT CONTROLLED ® PULL BOX CM CELING MOUNTED PB PULLBOX <br /> COMM COMMUNICATIONS PNL PANEL,PANELBOARD LOCATE DEVICES AS NOTED BELOW UNLESS OTHERWISE INDICATED.OUTLET b�'t>f M. <br /> 71 <br /> SINGLE-POLE SWITCH CTRL CONTROL POS POSITION/POINT OF SALE HEIGHTS ARE MEASURED FROM THE FINISHED FLOOR TO THE CENTERLINE OF cv�'�a <br /> EQUIPMENT CU COPPER PR PAIR[p THE OUTLET UNLESS OTHERWISE NOTED. c✓ <br /> D DATA PTS PNEUMATIC TUBE STATION ^eye _ A DIMMER SWITCH DC DIRECT CURRENT PWR POWER <br /> ONE-LINE DIAGRAM ® EQUIPMENT DED DEDICATED R RACEWAY RECEPTACLES 18"VERTICALLY MOUNTED <br /> $0 OCCUPANCY SENSOR SWITCH 57724 <br /> DEV DEVICE RO RACEWAY ONLY <br /> Q AVAILABLE FAULT CURRENT IDENTIFICATION CEP FUSED DISCONNECT DIV DIVISION RCP REFLECTED CEILING PLAN SWITCHES 43"VERTICALLY MOUNTED ,q,_ IST6�`" <br /> O AMMETER ON DOWN RCPT RECEPTACLE CLOCK OUTLET 80" "'dstONAL '� <br /> FIRE ALARM �� GROUND BAR,LENGTH TO SCALE DTS DRAWN TO SCALE REF REFRIGERATOR 0710e12624 <br /> • • ARRESTOR,SURGE DW DISHWASHER SLV SLEEVE 72"TO TOP OF <br /> DWG DRAWING SM SINGLEMODE PANELBOARD IN BOX IS <br /> a ARRESTOR,LIGHTNING MOTOR CONNECTION,SINGLE-PHASE PANELBOARDS <br /> SMOKE DETECTOR EF ENTRANCE FACILITY SMR SURFACE MOUNTED <68°HIGH,OTHERWISE <br /> ® AUTOMATIC TRANSFER SWITCH(ATS) �'y ER EQUIPMENT RACEWAY PER NEC 404.8 <br /> ❑ C MOTOR CONNECTION,THREE-PHASE ROOM/EMERGENCY ROOM SPECS SPECIFICATIONS INTERCOM I-❑ ❑ 43" <br /> " <br /> / � SPEAKER,WALL-MOUNTED&CEILING-MOUNTED BUSWAY END TAP EWC ELECTRIC WATER COOLER SW SWITCH <br /> ❑ SPD SURGE PROTECTIVE DEVICE FA FIRE ALARM SWBD SWITCHBOARD CARD READER 43 <br /> FB FLOOR BOX TELECOM TELECOMMUNICATIONS TELECOM OUTLET,DESK HANDSET 18"VERTICALLY MOUNTED <br /> ❑/ BUSWAY PLUG FBOIC FURNISHED BY OTHERS, TGB TELECOMMUNICATIONS <br /> ® TRANSFORMER INSTALLED BY CONTRACTOR GROUNDING BUSBAR TELECOM OUTLET,WALL HANDSET 43"VERTICALLY MOUNTED <br /> /l CAPACITOR FI FILM ILLUMINATOR TMGB TELECOMMUNICATIONS MAIN VOLUME CONTROLLER 43" <br /> FO FIBER OPTICAL GROUNDING BUSBAR <br /> n CIRCUIT BREAKER ® ENCLOSED CIRCUIT BREAKER FOC FACE OF COLUMN TR TELECOMMUNICATIONS ROOM FIRE ALARM PULL STATION 43" <br /> n CIRCUIT BREAKER, NETWORK PROTECTOR G,GND GROUND N TELEVISIONAFF <br /> GF AUTO DOOR PUSHPLATE GO GARBAGE DISPOSAL TYP TYPICAL TOP EDGE 96"BELOW <br /> CIRCUIT BREAKER,GA GEN GENERATOR UC UNDER COUNTER MINIMUM&6"BELOW <br /> n CEILING MINIMUM.(6" <br /> CIRCUIT BREAKER, DRAWOUT MGAP MEDICAL GAS ALARM PANEL GFl,GFCI GROUND FAULT CIRCUIT OF UNDER FLOOR FIRE ALARM AUDIBLE NO71FAC710N MINIMUM BELOW CEILING <br /> INTERRUPTER UG UNDER GROUND DEVICES <br /> XX HP HORSEPOWER HH HAND HOLEUL LABORATORIES CANNOT DE <br /> TAKES PRECEDENCE WHERE <br /> XX CIRCUIT BREAKER, DRAWOUT,MEDIUM VOLTAGE UNDERWRITERS' BOTH REQUIREMENTS <br /> HTR HEATER UON UNLESS OTHERWISE NOTED ) <br /> s•'�--�J CIRCUIT BREAKER,THERMAL OVERLOAD OF INDEPENDENT DISTRIBUTION UTP UNSHIELDED TWISTED PAIR FIRE ALARM VISUAL& BOTTOM EDGE 80"AFF <br /> CIRCUIT BREAKER, MAGNETIC OVERLOAD FRAME V VOLT OR VOICE COMBINATION AUDIBLE/VISUAL MINIMUM&TOP EDGE 96" <br /> IHW INSTA-HOT WATER VEL VERIFY EXACT LOCATION NOTIFICATION DEVICES AFF MINIMUM. <br /> ® ENCLOSED CIRCUIT BREAKER DISPENSER W WIRE,WATT,OR WALLPHONE PROVIDENCE <br /> JB,J-BOX JUNCTION BOX WAP WIRELESS ACCESS POINT FIRE ALARM CONTROL PANEL 72"TO TOP OF PANEL <br /> Ili CONTACT,NORMALLY OPEN&NORMALLY CLOSED TELECOM KV KILOVOLT WP WEATHERPROOF CT SIMULATOR <br /> KVA KILOVOLT AMPERE XFMR TRANSFORMER <br /> O CONTACTOR KW KILOWATT 0 PHASE <br /> 0 DELTA 0 PROVIDE OUTLET BOX WITH 1"C TO ACCESSIBLE SHEET LIST <br /> O ENGINE-GENERATOR COILING LOCATION TURNED TOWARDS NEAREST <br /> FUSE(ISOLATING) PUL1L ST NGGAND GR MMETEDWENDSONDUIT WITH <br /> SHEET NUMBER SHEET NAME <br /> EO.00-CT SYMBOLS AND ABBREVIATIONS <br /> FUSE OR CURRENT LIMITER p COMBO DATA AND VOICE OUTLET.PROVIDE OUTLET <br /> E0.01-CT ELECTRICAL SPECIFICATIONS <br /> BOX WITH 1"C TO ACCESSIBLE CEILING LOCATION 1717 13th St <br /> FUSED SWITCH TURNED TOWARDS NEAREST COMMUNCATIONS CLOSET. E7.00-CT COLBY CANCER CENTER- LEVEL 2-OVERALL PLAN Everett,WA 98201 <br /> i GROUND PROVIDE CONDUIT WITH PULL STRING AND GROMMETED El.11-CT LEVEL 2-CT SIMULATOR ELECTRICAL DEMOLITION PLANS <br /> O KEY INTERLOCK ENDS. <br /> E1.21-CT LEVEL 2-CT SIMULATOR ELECTRICAL PLANS <br /> O METER <br /> E1.22-CT LEVEL 2-ENLARGE CT SIMULATOR RACEWAY PLAN <br /> pM POWER METER NURSE CALL E5.01-CT ELECTRICAL DETAILS CONSTRUCTION <br /> ,J, PUSHBUTTON E6.01-CT LOAD CALCULATIONS AND PANEL SCHEDULES DOCUMENTS <br /> O RELAY r PATIENT TOILET STATION E7.01-CT NORMAL POWER ONE-LINE DIAGRAM <br /> STAFF ASSISTANCE STATION E7.02-CT EMERGENCY POWER ONE-LINE DIAGRAM <br /> RELAY,GFI <br /> SPD SURGE PROTECTIVE DEVICE <br /> .�. SWITCH,2-POLE <br /> H <br /> -ASWITCH,3-POLE <br /> Q SYMBOLS AND <br /> THERMAL ELEMENT ABBREVIATIONS <br /> TRANSFORMER <br /> rvvv� <br /> TRANSFORMER,CURRENT ISSUANCE <br /> No. Description Date <br /> VOLTMETER PERMIT SET 07/0812024 <br /> OV <br /> ®H WATT HOUR METER <br /> Y W'E <br /> m <br /> PROJECT INFORMATION <br /> PROJECT NUMBER: B24-1032 <br /> PROJECT LEAD: JGG <br /> DRAWN BY: CMB <br /> a <br /> SHEET NO <br /> E0.00-CT <br /> 1 2 3 4 5 6 7 8 9 10 11 <br />