ELECTRICAL SPECIFICATIONS: <br /> CITY OF EVERETT PERMIT SERVICES <br /> REVIEW DISCIPLINE:BUILDING PART 1-GENERAL WARRANTY TIME PERIOD DUE TO DEFECTIVE MATERIAL, CARTRIDGE FUSE INTERIORS,LOCKABLE HANDLE WITH BE REPAIRED TO EXISTING CONDITIONS AT NO COST TO THE <br /> BY:MWicklander FAULTY WORKMANSHIP,OR NON-COMPLIANCE WITH PLANS, CAPABILITY TO ACCEPT TWO PADLOCKS,AND INTERLOCKED OWNER. <br /> DATE <br /> 1REVIEWED/ 24FOR PERMIT 1.1 GENERAL CONDITIONS SPECIFICATIONS,CODE OR DIRECTIONS OF THE OWNER OR WITH COVER IN CLOSED POSITION. <br /> STATUS: .6 TESTING OF ELECTRICAL SYSTEMS <br /> OWNER'S REPRESENTATIVE,THE CONTRACTOR SHALL 3 VECA <br /> A. THE WORK UNDER THIS DIVISION INCLUDES FURNISHING ALL FURNISH ALL NECESSARY LABOR AND MATERIALS TO B. TYPE HD,HEAVY DUTY,SINGLE THROW,LARGER THAN 100A: <br /> PERMITS,MATERIALS,EQUIPMENT,LABOR,SUPERVISION, CORRECT THE MALFUNCTION AT NO ADDITIONAL COST TO UL 98 AND NEMA KS 1,HORSEPOWER RATED,WITH CLIPS OR A. EQUIPMENT INSTALLED OR MODIFIED UNDER THIS SECTION <br /> TOOLS,EXPENSES,TRAVEL,AND ITEMS NECESSARY FOR THE THE OWNER. BOLT PADS TO ACCOMMODATE FUSES,LOCKABLE HANDLE SHALL BE INSPECTED AND TESTED FOR PROPER OPERATION <br /> CONSTRUCTION,INSTALLATION,CONNECTION,TESTING AND WITH CAPABILITY TO ACCEPT THREE PADLOCKS,AND IN ACCORDANCE WITH APPLICABLE NETA ACCEPTANCE ELECTRIC&TECHNOLOGIES <br /> CITY OF EVERETT PERMIT SERVICES OPERATION OF ALL ELECTRICAL WORK FOR THIS PROJECT, PART 2-PRODUCTS INTERLOCKED WITH COVER IN CLOSED POSITION. TESTING STANDARDS. <br /> REVIEW DISCIPLINE'.BUILDING AS INTENDED BY THE CONTRACT DOCUMENTS. <br /> BY:MWicklander C.2.1 MATERIAL C ACCESSORIES: <br /> DATE:10/21/2024 B. THE GENERAL CONDITIONS,SUPPLEMENTARY CONDITIONS B. SYSTEMS SHALL BE TESTED FOR SHORT CIRCUITS,OPEN <br /> AND SPECIAL CONDITIONS ARE A PART OF THIS CONTRACT A. MATERIALS SHALL BE NEW,FREE OF DEFECTS AND OF 1. CLASS R FUSE KIT:PROVIDES REJECTION OF OTHER FUSE CIRCUITS,PHASE ROTATION AND SHALL BE FREE FROM <br /> STATUS:REVIEWED FOR PERMIT AND APPLY TO THIS SECTION AS FULLY AS IF REPEATED CURRENT MANUFACTURE.EXISTING MATERIALS SHALL NOT TYPES WHEN CLASS R FUSES ARE SPECIFIED. MECHANICAL AND ELECTRICAL DEFECTS. <br /> HEREIN. BE REUSED UNLESS SPECIFICALLY NOTED OTHERWISE. CONSULTANTS <br /> PART 3-EXECUTION C. THE CONTRACTOR SHALL CORRECT DEFICIENCIES AND <br /> 1.2 CODES AND REGULATIONS 2.2 WIRE AND CABLE(600 VOLT AND LESS) PROVIDE RETESTING AT NO EXPENSE TO THE OWNER AND <br /> SUBJECT TO FIELD 3.1 INSTALLATION OF ELECTRICAL EQUIPMENT ENGINEER UNTIL THE EQUIPMENT AND SYSTEM IS <br /> INSPECTION A. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH A. PRODUCTS SHALL COMPLY WITH UL 44 AND UL 83 SINGLE SATISFACTORY TO THE OWNER AND THE ENGINEER. <br /> APPLICABLE REQUIREMENTS OF THE AUTHORITY HAVING CONDUCTOR INSULATED WIRE. <br /> JURISDICTION AND THE UTILITY FURNISHING SERVICES FOR A. INSTALL EQUIPMENT IN ACCORDANCE WITH <br /> THE SPECIFIC FACILITY LOCATION. B. WIRE AND CABLE FOR USE ON SYSTEMS OF 600 VOLTS AND MANUFACTURER'S INSTRUCTIONS,NECA STANDARD OF GENERAL NOTES: <br /> LESS SHALL BE 600 VOLT WITH NEC TYPE THHN/THWN OR INSTALLATION AND IN ACCORDANCE WITH THE UL LISTING EVIDENCE <br /> City of Everett Permit Review B. CODES GOVERNING THIS WORK INCLUDE BUT ARE NOT XHHW INSULATION FOR BRANCH CIRCUITS AND FEEDERS FOR THE EQUIPMENT OR MATERIAL. 1. COMPLY WITH NEC AS ADOPTED AND AMENDED BY LOCAL <br /> EVERETT Status:Approved as Noted LIMITED TO THE LATEST ADOPTED EDITION OF THE SMALLER THAN#2AWG.XHHW INSULATION SHALL BE USED ALL DISCONNECTS,FUSES,CIRCUIT BREAKERS SHALL BE AHJ. BD � <br /> BASED <br /> FOLLOWING: FOR#2AWG AND LARGER FEEDER CONDUCTORS. PROVIDED AS INDICATED AND FOR PROPER PROTECTION OF DESIGN <br /> 10/21/2024 3:43:55 PM NFPA 70(NATIONAL FIRE PROTECTION ASSOCIATION) 1. USE TYPE THHN/THWN CONDUCTORS FOR ALL BRANCH THE EQUIPMENT SERVED.PROVIDE ALL FLEXIBLE CONDUIT, 2.ALL EXISTING WORK IS BASED ON RECORD DRAWINGS <br /> NATIONAL ELECTRICAL CODE(NEC)AS AMMENDED BY POWER AND LIGHTING CIRCUITS. BOXES PULL BOXES,FITTINGS,SEALS,AND OTHER AND HAS NOT BEEN FIELD VERIFIED IN FULL.THE SERVICES <br /> WASHINGTON CITIES(2020 WCEC) 2.USE TYPE XHHW IN AMBIENT TEMPERATURES BELOW 32°F. MATERIALS REQUIRED FOR A COMPLETE AN OPERATIONAL ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL <br /> NFPA 72(NATIONAL FIRE PROTECTION ASSOCIATION) USE TYPE XHHW-2 FOR ALL WIRING CONNECTED TO GFCI SYSTEM. EXISTING INFORMATION RELEVANT FOR THE SCOPE OF <br /> NATIONAL FIRE ALARM AND SIGNALING CODE BREAKERS. THE WORK UNDER THIS DIVISION INCLUDES FURNISHING ALL THIS PROJECT. <br /> NFPA 101(NATIONAL FIRE PROTECTION ASSOCIATION)LIFE PERMITS,MATERIALS,EQUIPMENT,LABOR,SUPERVISION, <br /> SAFETY <br /> CITY OF EVOERETT ORDINANCES AND REGULATIONS DE C. ALL GROUNDING CONDUCTORS SHALL BE INSULATED. TOOLS AND NSTALLATIONEMS NECESSA CONNECTIONRY FOR THE CONSTRUCTION, <br /> TESTING AND OPERATION OF 3. ALL SCOPE NOT IDENTIFIED FOR DEMOLITION OR \,o WASH/j� <br /> D. MC OR HCF-MC CABLE SHALL BE PERMITTED FOR LIMITED ALL ELECTRICAL WORK FOR THIS PROJECT,AS INTENDED BY MODIFICATIONS IS EXISTING TO REMAIN.REFER TO tiPw ty <br /> 1.3 STANDARDS USE AS FOLLOWS: THE CONTRACT DOCUMENTS. ELECTRICAL DRAWINGS FOR DEMOLITION SCOPE OF <br /> WORK. <br /> A. ELECTRICAL MATERIAL AND EQUIPMENT SHALL BE 1. TEMPORARY POWER PROVISIONS 3.2 INSTALLATION OF RACEWAY AND FITTINGS ` <br /> UNDERWRITER'S LABORATORIES LISTED AND INSTALLED IN 2.EQUIPMENT CONNECTIONS TO COMPENSATE FOR 4.ALL WORK SHALL BE DONE WITH MAXIMUM CARE A 5772a <br /> ACCORDANCE WITH THE LISTING AND LABELING OF THE MOVEMENT AND VIBRATION. EXERCISED DURING DEMOLITION AND MODIFICATIONS ����ECIST �'��F <br /> EQUIPMENT. 3.TERMINAL CONNECTIONS TO LIGHT FIXTURES NOT TO A. INSTALL RIGID STEEL CONDUIT WHERE EXPOSED TO PROCESS.ANY ACCIDENTAL OR INTENTIONAL DAMAGE TO �S'9/ONAL <br /> EXCEED 6 FEET IN LENGTH. WEATHER,PLACED UNDERGROUND,IN OR UNDER CONCRETE EQUIPMENT TO REMAIN SHALL BE REPAIRED AT NO <br /> B. INSTALLATION SHALL CONFORM TO THE NECA(NATIONAL 4. LIGHTING AND BRANCH CIRCUITS. OR MASONRY CONSTRUCTION,IN CONTACT WITH EARTH AND ADDITIONAL COST TO THE OWNER. <br /> ELECTRICAL CONTRACTORS ASSOCIATION)STANDARD OF S. CONCEALED AREAS INDOORS. AS INDICATED ON PLANS. <br /> INSTALLATION. 5. UNLESS OTHERWISE REQUESTED BY THE OWNER ALL MEDICAL VACUUM <br /> 2.3 RACEWAY AND BOXES B. EMT MAY BE USED IN ABOVE GRADE INTERIOR DRY REMOVED ELECTRICAL EQUIPMENT,DEVICES,AND <br /> 1.4 SUBMITTALS LOCATIONS AND WHERE PROTECTED FROM PHYSICAL MATERIALS SHALL BE DISPOSED OF BY THE ELECTRICAL PUMP REPLACEMENT <br /> A. RIGID STEEL CONDUIT,ZINC COATED;ANSI C80.1:ALL DAMAGE. CONTRACTOR. <br /> A. ELECTRONIC COPIES,IN.PDF FORMAT,OF MATERIALS LIST, FITTINGS SHALL BE SCREW THREAD TYPE,COUPLINGS, <br /> SHOP DRAWINGS AND DATA SHEETS SHALL BE SUBMITTED LOCKNUTS,BUSHINGS,ETC.SHALL BE HOT DIPPED C. FLEXIBLE METAL CONDUIT SHALL BE USED WHERE REQUIRED 6. ALL WORK SHALL BE DONE ON DE-ENERGIZED EQUIPMENT <br /> TO THE ENGINEER FOR REVIEW.SUBMITTALS SHALL BE GALVANIZED. TO MAKE CONNECTIONS TO VIBRATING OR ROTATING ONLY AND ALL LOTO(LOCK-OUT TAG OUT)PROCEDURES <br /> MADE,AND FAVORABLE REVIEW SECURED BEFORE EQUIPMENT. SHALL BE FOLLOWED AS REQUIRED PER NEC AND OSHA. <br /> MATERIAL AND EQUIPMENT IS INSTALLED. B. ELECTRICAL METALLIC TUBING,ZINC COATED:ANSI C80.3: <br /> COUPLINGS AND CONNECTORS SHALL BE STEEL D. ALL RIGID STEEL CONDUIT INSTALLED IN CONTACT WITH PROVIDENCE REGIONAL MEDICAL <br /> B. MATERIALS LIST SHALL INCLUDE:DEVICES,DISCONNECTS, GALVANIZED,COMPRESSION TYPE WITH GLAND SEALING EARTH SHALL BE PVC COATED OR OTHERWISE PROTECTED CENTER <br /> AND OTHER ITEMS SPECIFIED OR CALLED FOR ON THE RINGS. WITH A BITUMASTIC MATERIAL. <br /> DRAWING.THE LIST SHALL INCLUDE MANUFACTURE,TYPE PACIFIC CAMPUS <br /> AND SUCH OTHER DESCRIPTIVE DATA AS MAY BE REQUIRED C. FLEXIBLE METAL CONDUIT:UL 1:FLEXIBLE METAL CONDUIT E. MINIMUM SIZE OF CONDUIT SHALL BE CODE SIZE FOR THE 916 PACIFIC AVE <br /> TO DETERMINE THE ACCEPTABILITY OF EACH ITEM. SHALL BE GALVANIZED STEEL OR ALUMINUM.WHERE <br /> EXPOSED TO DAMP OR WET LOCATIONS FLEXIBLE CONDUIT NUMBER AND SIZE OF CONDUCTORS UNLESS A LARGER SIZE EVERETT,WA 98201 <br /> C. SHOP DRAWINGS AND DATA SHEETS FOR EQUIPMENT AND SHALL BE LIQUID-TIGHT WITH OUTER SUITABLE LIQUID-TIGHT IS INDICATED ON THE PLANS. <br /> SYSTEMS SHALL BE SUBMITTED WHERE REQUIRED IN THE FITTINGS LISTED FOR THE PURPOSE. <br /> SPECIFICATIONS FOR THOSE ITEMS.INCLUDE INFORMATION F. WHERE PENETRATIONS ARE MADE THROUGH PARTITIONS, <br /> ON EACH COMPONENT,WIRING DIAGRAMS,LAYOUTS, D. OUTLET AND JUNCTION BOXES:OUTLET AND JUNCTION PROVIDE SEALING MATERIAL TO MAINTAIN THE FIRE RATING <br /> DIMENSIONS AND SUFFICIENT OTHER DATA TO ESTABLISH BOXES SHALL BE GALVANIZED,ONE-PIECE PRESSED OR OF THE PARTITION.FOR EXTERIOR WALLS PROVIDE SLEEVES <br /> COMPLIANCE WITH THE SPECIFICATIONS AND ACCEPTABILITY WELDED STEEL,KNOCKOUT TYPE EXCEPT AS OTHERWISE AND SEALING TO PREVENT WATER AND MOISTURE <br /> OF THE EQUIPMENT OR SYSTEM. NOTED OR SPECIFIED. PENETRATION AND TO PREVENT VARMINT AND INSECT <br /> INTRUSION. <br /> D. PROVIDE PRODUCT DATA AND SHOP DRAWINGS FOR THE E. PROVIDE FIRE-STOPPING WHERE CONDUIT PASSES THROUGH <br /> FOLLOWING: A RATED ASSEMBLY. 3.3 INSTALLATION OF CONDUCTORS AND EQUIPMENT <br /> CONNECTIONS <br /> 1. FUSED DISCONNECT SWITCHES 2.4 WIRING DEVICES(PROVIDE DEVICES PER DRAWINGS) <br /> 1.5 SUBSTITUTIONS A. CIRCUITING: A. ALL WIRING SHALL BE INSTALLED IN CONDUIT,WIREWAYS, <br /> 1. 480/277V BRANCH CIRCUIT WIRING SHALL BE IN SEPARATE OR GUTTERS EXCEPT WHERE OTHER RACEWAY SYSTEMS CONSTRUCTION <br /> A. NO SUBSTITUTIONS ARE ALLOWED.ALTERNATIVE CONDUITS FROM 2081120V CIRCUIT WIRING. ARE SPECIFICALLY CALLED FOR. <br /> MANUFACTURERS WILL BE CONSIDERED FOR ELECTRICAL <br /> EQUIPMENT SPECIFIED AND SHOWN HEREIN.THE SPECIFIED 2.5 ENCLOSURES B. INSTALL WIRING ONLY AFTER RACEWAY INSTALLATION HAS DOCUMENTS <br /> MANUFACTURER'S EQUIPMENT SETS THE LEVEL OF QUALITY BEEN COMPLETED CLEANED AND DRIED. <br /> FOR THE WORK. A. ENCLOSED SWITCHES AND CIRCUIT BREAKERS: NEMA AS 1, <br /> NEMA KS 1,NEMA 250,AND UL 50,TO COMPLY WITH C. PULLING LUBRICANTS APPROVED BY THE WIRE OR CABLE <br /> WORK AND EQUIPMENT NOT MEETING THE LEVEL OF QUALITY ENVIRONMENTAL CONDITIONS AT INSTALLED LOCATION. MANUFACTURE MAY BE UTILIZED. <br /> SHALL BE REJECTED.THE ENGINEER HAS DISCRETION TO 1. INDOOR,DRY AND CLEAN LOCATIONS: NEMA 250,TYPE 1. <br /> ACCEPT OR REJECT THE ALTERNATIVE MANUFACTURER'S 2.OUTDOOR LOCATIONS: NEMA 250,TYPE 3R. D. MAKE ALL CONNECTIONS AND SPLICES REQUIRED FOR <br /> EQUIPMENT. <br /> 3. WASH-DOWN AREAS: NEMA 250,TYPE 4X,STAINLESS COMPLETE AND OPERABLE ELECTRICAL INSTALLATION. <br /> 1.6 PERMITS AND DRAWINGS STEEL. CONNECTIONS AND SPLICES SHALL BE MADE ONLY IN <br /> 4. OTHER WET OR DAMP,INDOOR LOCATIONS: NEMA 250, JUNCTION,PULL OR OUTLET BOXES OR IN WIREWAYS, <br /> A. PERMITS AND INSPECTIONS SHALL BE OBTAINED, TYPE 4. SWITCHBOARDS AND PANELBOARDS HAVING CODE SIZED <br /> COORDINATED AND PAID FOR BY THE ELECTRICAL 5. INDOOR LOCATIONS SUBJECT TO DUST,FALLING DIRT, GUTTER SPACE OR CROSS-SECTIONAL AREA.WIRES#8 AND <br /> CONTRACTOR. AND DRIPPING NONCORROSIVE LIQUIDS: NEMA 250,TYPE SMALLER CONNECTIONS SHALL BE MADE WITH SPRING TYPE <br /> 12 CONNECTORS;WIRES#6 AND LARGER,CONNECTIONS SHALL <br /> B. THE CONTRACTOR SHALL PAY ALL FEES AND TAXES FOR THE BE MADE WITH SPLIT-BOLT OR COMPRESSION TYPE <br /> TOTAL COST OF CONSTRUCTION,INCLUDING CONTRACTOR 2.6 GROUNDING SOLDERLESS CONNECTORS,INSULATED AND TAPED. <br /> AND OWNER FURNISHED MATERIALS AND EQUIPMENT AS <br /> SHOWN AND SPECIFIED. E. UPON COMPLETION OF WORK,UPDATED ALL PANEL <br /> A. PROVIDE COPPER GROUNDING. DIRECTORIES WITH CORRECT CIRCUIT INFORMATION. <br /> C. THE CONTRACTOR SHALL OBTAIN AND PAY THE PLAN REVIEW PROVIDE PRINTED CIRCUIT DIRECTORIES IN PANELS <br /> FEE. B. PROVIDE DEDICATED NEUTRAL(NO SHARED NEUTRALS)WITH AFFECTED BY THE PROJECT.PEN AND INK CHANGES TO THE <br /> ALL BRANCH CIRCUITS IN EACH CONDUIT.USE OF EXISTING DIRECTORIES ARE NOT ACCEPTABLE. <br /> D. THE CONTRACTOR SHALL PAY FOR PLAN REVIEW FEES AND MULTI-POLE BREAKERS OR BREAKER TIES IN LIEU OF <br /> RE-INSPECTIONS RESULTING FROM SUBSTITUTIONS. FEES DEDICATED NEUTRALS IS NOT PERMITTED. 3.4 GROUNDING <br /> DUE TO SUBSTITUTIONS SHALL BE AT NO COST TO THE <br /> OWNER. C. ALL CONDUITS WILL BE PROPERLY BONDED WITH INSULATED A. PERMANENTLY AND EFFECTIVELY GROUND ALL CONDUIT, <br /> GROUND WIRE RUN WITH CONDUCTORS. BOXES,ENCLOSURES AND EQUIPMENT TO COMPLY WITH NEC <br /> E. THE CONTRACTOR SHALL INCLUDE APPLICABLE PLAN 250 AND ALL APPLICABLE CODES AND REGULATIONS. <br /> REVIEW FEES AND RE-INSPECTION FEES IN CHANGE ORDER D. ALL PANELS AND TRANSFORMERS MUST HAVE A DEDICATED <br /> PROPOSALS. EQUIPMENT GROUNDING CONDUCTOR IN ADDITION TO <br /> ELECTRODE OR BUILDING GROUNDS AS REQUIRED PER B. PROVIDE INSULATED EQUIPMENT GROUNDING <br /> 1.7 RECORD DRAWINGS CONDUCTOR IN ALL RACEWAYS SIZED IN ACCORDANCE WITH - 10/18/2024 CONSTRUCTION DOCUMENTS <br /> CODE. NEC TABLE 250.122 WHETHER SPECIFICALLY CALLED FOR ON MARK DATE DESCRIPTION <br /> A. ON A SET OF CONTRACT DRAWINGS KEPT AT THE SITE THE PLANS OR NOT. <br /> DURING CONSTRUCTION,MARK ALL WORK THAT IS 2.7 EQUIPMENT IDENTIFICATION PROJECT NO:B24-1119 <br /> INSTALLED DIFFERENTLY FROM THAT SHOWN,INCLUDE ANY 3.5 PROTECTION OF PREMISES CAD DWG FILE:E01.DWG <br /> REVISED CIRCUITRY,MATERIAL OR EQUIPMENT.UPON A. ENCLOSED CIRCUIT BREAKERS,DISCONNECT SWITCHES, <br /> CONCLUSION OF THE WORK,DELIVER TO THE OWNER RECEPTACLES AND LIGHT SWITCHES: PRINTED LABEL WITH A. CONTRACTOR SHALL CLEAN WORK AREA AND REMOVE ALL DRAWN BY:CRS <br /> REPRESENTATIVE A SET OF SIGNED AND DATED"AS-BUILT" (PANEL)NAME AND CIRCUIT NUMBER.(EXAMPLE:"PP4-23" CONSTRUCTION DEBRIS DAILY PRIOR TO LEAVING THE CHK'D BY:KMD <br /> DRAWINGS. FOR PANEL PP4,CIRCUIT 23) PREMISES. COPYRIGHT: <br /> NORMAL POWER:'/e"BLACK LETTERS <br /> 1.8 WARRANTY EQUIPMENT BRANCH POWER:''/4"RED LETTERS <br /> B. THE CONTRACTOR SHALL PROTECT ALL EXISTING SURFACES, <br /> A. ALL WORK SHALL INCLUDE A WARRANTY FOR A MINIMUM CRITICAL BRANCH POWER:'/."RED LETTERS MATERIALS,EQUIPMENT AND PROPERTY FROM DAMAGE AS SHEET TITLE <br /> PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE BY LIFE SAFETY BRANCH POWER:'/,"RED LETTERS RESULT OF CONSTRUCTION ACTIVITIES. DAMAGED ELECTRICAL <br /> THE OWNER.THE WARRANTY PERIOD FOR CERTAIN ITEMS SURFACES,MATERIALS,EQUIPMENT AND PROPERTY SHALL <br /> SHALL BE LONGER,AS INDICATED IN THE SPECIFICATIONS 2.8 FUSIBLE SWITCHES <br /> FOR THOSE ITEMS. SPECIFICATIONS <br /> A. TYPE Go,GENERAL DUTY,SINGLE THROW,100A AND <br /> B. SHOULD ANY MALFUNCTION DEVELOP DURING THE SMALLER;UL98 AND NEMA KS 1,HORSEPOWER RATED,WITH <br /> E0.1 <br />