My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2520 MADISON ST 2022 DISH WIRELESS Plans 2025-07-14
>
Address Records
>
MADISON ST
>
2520
>
DISH WIRELESS
>
Plans
>
2520 MADISON ST 2022 DISH WIRELESS Plans 2025-07-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/14/2025 10:47:59 AM
Creation date
7/7/2025 1:37:15 PM
Metadata
Fields
Template:
Address Document
Street Name
MADISON ST
Street Number
2520
Tenant Name
DISH WIRELESS
Permit
B2208-087
Year
2022
Notes
DISH INSTALL NEXT TO EXISTING WCF
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CARLON EXPANSION FITTINGS • <br /> SEE TRENCHING NOTE 1 DISHWireless LLC. O 0 O DISH Wlroleaa LLC. FIBER <br /> MALE TERMINAL STD I I DISTRIBUTION PANEL <br /> COUPLING END ADAPTER END SIZE CTN TRAVEL VARIES PER BACKFILL PER SITE WIRE (6' TAIL) —PROPOSED DISH Wireless LLC. d NI/ sh <br /> PART# PART/ Qom, LENGTH PART NUMBER TRENCHING NOTESI WORK ENECIFlGTITES TELCO FIBER ENCLOSURE <br /> 1. CONTRACTOR SWILL RESTORE THE (SEE GENERAL NOTES) <br /> E945D E945DX 1/2` 20 4" TRENCH TO RS ORIGINAL SLOPE TO SUIT SOIL 1f j�r wkeless. <br /> E945EX 3/4' 15 4` I SUP JOINT CONDITIONS BY ETHER SEEDING SSEELOI IXNALINREGUUTIONSCE 0 <br /> (SEE CHART FOR OR SODDING GRASS AREAS, OR WTTH <br /> E945F E945FX 1' 10 4' I-1 PART NUMBER) REPLACING ASPHALT OR CONCRETE SEE TRENCHING NOTE 2 LLC.PROUNNIISTRIUT SH Wireless <br /> 5701 SOUTH SANTA FE DRIVE <br /> AREAS TO RS ORIGINAL CROSS .// / -tiE=Car� LITTLETON, CO 80120 <br /> E945G E945GX 1 1/4' 5 4' BECKON. / / j'1'�"'"'"' DISH Wireless LLC. FIBER <br /> 2. TRENCHING SAFETY; INCLUDING, / R JUMPER TO CABINET WILL <br /> NEED TO BE TERMINATED BY <br /> E945H E945HX 1 1/2' 5 4' 4 BUT NOT CLASSIFICATION,UNITED TO <br /> //�\ /` i,< FIBER PROVIDER ON OTHER <br /> E945J E945JX 2` 15 8' �� .� PROPOSED DISH SIDE OF BULKHEAD/LC TO LC <br /> SHORING, SHALL BE GOVERNED z /// /• I,P Wireless LLC. CONNECTOR WHERE CIRCUIT <br /> E945K E94510( 2 1/2' 10 8" BY THE CURRENT OSHA iI r / i 7 10 AMP DISTRIBUTION IS TERMINATED. <br /> TRENCHING AND EXCAVATION \// : ••.s /% �121 BREAKER °� AMICRICANDER° <br /> E945L E945LX 3' 10 8' - SAFETY STANDARDS. c j ;�.:y:.: Q >-- A.T.ENGINEERING SERVICE,PLLC <br /> E945M E945MX 3 1/2' 5 8" 3. ALL CONDUITS SHALL BE / •.. % ��iii IN IN °• 3500 REGENCY PARKWAY <br /> NI INSTAI I Fn IN COMPLIANCE WITH '� `. FIBERPROP LATERAL <br /> FIBER PROVIDER <br /> E945N E945NX 4' 5 8" �� e / �� "r Q o FIBER LATERAL FROM RIGHT SUITE 100 <br /> THE CURRENT NATIONAL • \ PROPOSED DISH Wireless LLC. OFc 1 NC 27s1e <br /> UTILITY WARNING TAPE 12 AWG WIRE \ \ \ TERMINATED WAY TO STREET, PHONE:{919)468-0112 <br /> E945P E945PX 5" 1 8" ELECTRIC CODE (NEC) OR AS PROPOSED DISH Wireless LLC. �\ \ �— RPO TO FDP <br /> NOTE REQUIRED BY THE LOCAL SAND BEDDING PER SITE 1-1/2' POWER FROM CABINET- - \ \ PROPOSED DISH Wireless LLC. <br /> E945R E945RX 6' 1 8" COSUPPJJOINT AT MACTOR TO INSTALL EXPANSION ETER CENTER CONDUITFITTING JURISDICTION, <br /> EN MISOSSTRINGENT. IS WORK SPECIFICATIONS DISH Wireless LLC. INSTALLS // 1-1/2" FIBER TO CABINET CORE ONE <br /> TERMINATION, AS PER LOCAL UTILITY POLICY, 1-1/2' CONDUITS FOR POWER V PROPOSED DISH Wireless LLC. CONSULTING U S A <br /> ORDINANCE AND/OR SPECIFIED REQUIREMENT. AND FIBER TO CABINET 2" CONDUIT FROM COMMERCIAL <br /> FIBER VAULT 4515 S. MCCLINTOCK DRIVE, SUITE 217 <br /> TEMPE, AZ 85282 <br /> EXPANSION JOINT DETAIN, NO SCALE 1 TYPICAL UNDERGROUND TRENCH DETAIL NO SCALE 2 DARK TELCO BOX - INTERIOR WIRING LAYOUT NO cr-AlF 3 <br /> DRAWN BY: CHECKED BY:APPROVED BY: <br /> • <br /> PRI SRF SRF <br /> REDS REV #: 4 <br /> NOTE: FIBER PROVIDER <br /> PROPOSED FIBER WILL NA TO PUNISTRUT CONSTRUCTION <br /> PROPOSED DISH Wireless LLC. RID, IF REQUIRED 2 U-BOLTS WITH 4 NUTS, <br /> UNISTRUT \ IN THE EVENT THE DOCUMENTS <br /> BRACKET SPACING DOESN'T <br /> - UNE UP WITH CURRENT <br /> SPACING BELOW SUBMITTALS <br /> PROPOSED FIBER PROVIDER IN IN OUT REV DATE DESCRIPTION <br /> 1-1/4'FLEX CONDUITS <br /> FIBER PROVIDER TO TERMINATE j!UI'II I FIBER PROVIDER TO PUNCH TOP OF - �--' %��� g9OED FDR Re/IEW <br /> POWER TO FIBER PROVIDER NID TELCO BOX OF NID ENCLOSURE AND D 05/00/22 ISSUED TOR CONSTRUCTION <br /> bitPROPOSED DISH Wireless LLC. INSTALL 1-1/4" LIQUID TIGHT <br /> 12 AWG WIRE (6' TAIL) CONNECTORS, UL LISTED, NYLON -- <br /> MATERA., WITH 0-RING GASKET <br /> NMI, <br /> + _ �tl - FIBER PROVIDER TO INSTALL <br /> PROPOSED DISH Wireless LLC. --�� 1-1/4' FLEX CONDUITS BETWEEN <br /> 10 AMP DISTRIBUTION BREAKER MIN: FDP TELCO BOX & NID <br /> PROPOSED DISH Wireless LLC. <br /> PROPOSED DISH Wireless LLC. TELCO FIBER ENCLOSURE C // <br /> 12 AWG WIRE III <br /> PROPOSED-i2 DISH <br /> ER TO CABINET <br /> LLC. <br /> P�L B A. `�F <br /> ����`'F W ASyj,.'OF <br /> PROPOSED DISH Wireless LLC. ' (9� PROPOSED DISH Wireless LLC. N .. <br /> 1-1/2' POWER FROM CABINET I11,� 2' CONDUIT FROM COMMERCIAL ,� k;•. OZ <br /> P FIBER VAULT I r <br /> r <br /> LIT TELCO BOX - INTERIOR WIRING LAYOUT (OPTIONAL) NO SCALE 4 NOT USED NO SCALE 5 NOT USED NO SC1IF 6 -o ' 4 <br /> p 56058 ��v <br /> ��� ''CISTER�� 4 <br /> Ss/0NA �4 <br /> IT IS A VIOLATION OF LAW FOR ANY PERSON, <br /> UNLESS THEY ARE ACTING UNDER THE DIRECTION <br /> OF A LICENSED PROFESSIONAL ENGINEER, <br /> TO ALTER THIS DOCUMENT. <br /> A&E PROJECT NUMBER <br /> 83177-13773495_D3 <br /> DISH Wireless L.L.C. <br /> PROJECT INFORMATION <br /> SESEA00501A <br /> 2530 MADISON STREET <br /> EVERETT, WA 98203 <br /> SHEET TITLE <br /> ELECTRICAL DETAILS <br /> SHEET NUMBER <br /> E-2 <br /> NOT USED NO SCALE 7 NOT USED NO SCALE 8 NOT USED NO SCALE 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.