e <br /> rr <br /> d me•FS h <br /> wireless. <br /> PROPOSEDPOWER PROTECTIVE CABINET CHARLES NETWORK CABINET 5701 SOUTH SANTA FE DRIVE <br /> UTILITY SERVICE ENTRANCE OVERALL <br /> 1 PH, SERVICE RATED, LITTLETON, CO 50120 <br /> 120/240 VAC 1PH OVERALL UL LISTED POWER CENTER, <br /> N3R, 65K/10K NC <br /> I <br /> (3) 3/0 WITH #8 GROUND 0 [ BACKUP 11 MAIN BREAKER WTTH <br /> IN 3'SCH 40 CONDUIT GENERATOR 200A 400A INTERLOCKED GENERATOR (2) PROPOSED <br /> CAMLOCK FEED, 200A 65K NC 3/4' EMT CONDUITS <br /> CONTRACTOR TO REFER TO 0 <br /> GEN PLUG <br /> O INCOMING 120/240V, 103W, UTILITY FEED FINAL IrnUTY DESIGN DETAILS N AMlRICANTOWERa <br /> SURGE SUPPRESSIO � <br /> DEVICE 100KA SAD/MOV A.T.ENGINEERING SERVICE,PLLC <br /> 3500 REGENCY PARKWAY <br /> 0 GFCI 15A Ot 02 30A PROPOSED 2 #10, 1 #10 CU GND. + FOR RECTIFIER 1 CA SUITE 100 <br /> RY,NC 27518 <br /> PROPOSED WIRE AND CONDUIT PER 1 03 04�_ PHONE:(919)488-0112 <br /> UTILITY COMPANY REQUIREMENTS <br /> SPACE � <br /> -^ 08_5______ -II <br /> 3oA PROPOSED 2 #10 <br /> © J - I FOR RECTIFIER 2 <br /> 07 � <br /> SPACE 0 CORE ONE <br /> PROPOSED 200A, 120/240V, 14 C 0 0� CONSULTING U S A <br /> SERVICE RATED,COMBINATION SPACE 30A PROPOSED 2 #10, 1 #10 CU GND. + FOR RECTIFIER 3 <br /> METER/DISCONNECT(NEMA 3R)WITH TEST ,--- 11 12r-), <br /> BLOCK BYPASS (MILBANK MODEL.No. 4515 S. MCCLINTOCK DRIVE, SUITE 217 <br /> a U5240-0-2005 MIDWEST ELECTRIC SPACE 13 14 TEMPE,AZ 85282 <br /> Q MODEL No. M28101P8H /ORE ��E15 18 PROPOSED 2 #10 J + FOR RECTIFIER 4 <br /> 2G LOCAL <br /> UTUT VERIFYCOMPANY. <br /> M COMPATIBILITYCION WITH DRAWN BY: CHECKED BY:APPROVED BY: <br /> #4 CU (GROUNDING MAINBONDING COMP. LOCATION OF SPACE 17 18. <br /> ELECTRODE CONDUCTOR) SPACE 20�SPACE (1) PROPOSED PRI SRF SRF <br /> SPACE SPACE 1/2' EMT CONDUIT <br /> SPACE 2 ��SPACE REDS REV #: 4 <br /> GROUNDING ELECTRODE SHALL BE SPACE 23 24 SPACE <br /> (2) 5/8'e X 10' LONG GROUND ROD PROPOSED 2 #10, 1 #10 CU GND. CONSTRUCTION <br /> OSPACED MINIMUM 6'APART + FOR CONVENIENCE OUTLET DOCUMENTS <br /> gQi SUBMITTALS <br /> BRANCH CIRCUIT WIRING SUPPLYING RECTIFIERS ARE TO BE RATED UL1015, 10SC, 600V, AND PVC INSULATED, IN THE SIZES SHOWN REV DATE DESCRIPTION <br /> IN THE ONE-UNE DIAGRAM. CONTRACTOR MAY SUBSTITUTE UL1015 WIRE FOR THWN-2 FOR CONVENIENCE OUTLET BRANCH CIRCUIT. <br /> BREAKERS REWIRED. <br /> 07/Oe/22 ISSUED FUR FOAM <br /> (4) 30A. 2P BREAKER - SQUARE D P/N:Q0230 0 0e/08/22 Issue FUR COW/RUCTION <br /> (2) 15A, 1P BREAKER - SQUARE D P/N:Q0115 <br /> .119- <br /> PPC ONE-LINE DIAGRAM NO SCALE 1 ' B. <br /> h O <br /> s ., .z <br /> 56058 �� <br /> 1) 56058 <br /> PROPOSED CHARLES PANEL SCHEDULE <br /> VOLT AMPS VOLT AMPS <br /> LOAD SERVED (WATTS) TRIP C#KKT PHASE C#KKT TRIP (WATTS) LOAD SERVED <br /> L1 L2 L1 L2 <br /> PPC GFCI OUTLET 180 15A 1 -,-,-, A -,T, 2 2880 ABB/GE INFINITY IT IS A VIOLATION OF LAW FOR ANY PERSON, <br /> CHARLES GFCI OUTLET ECM 15A 3 -rt. B ../L 4 :Q: RECTIFIER 1 UNLESS THEY ARE ACTING UNDER THE DIRECTION <br /> OF A LICENSED PROFESSIONAL ENGINEER, <br /> -SPACE- 5 -�- A 8 30A 2880 ABB GE INFINITY TO ALTER THIS DOCUMENT. <br /> -SPACE- I= 7 -^- B 8 :0: RECTIFIER 2 <br /> -SPACE- 9 fT A 10 :®:� ABB/GE INFINITY <br /> -SPACE- 11-f". B 12 304 I RECTIFIER 3 A&E PROJECT NUMBER <br /> -SPACE- 13 A 14 30A 2880 ABB/GE INFINITY <br /> -SPACE- == 15-n- B 18 2880 RECTIFIER 4 83177-13773495_03 <br /> -SPACE- == 17 A -rL.18 -SPACE- <br /> -SPACE- == 19 B _r'1..20 -SPACE- <br /> -SPACE- 21-n- A 22 == -SPACE- DISH Wireless L.LC. <br /> -SPACE- 23,-r B - 24 -SPACE- PROJECT INFORMATION <br /> ti r'- <br /> VOLTAGE AMPS I 180 II 180 111520 111520 SESEA00501 A <br /> 200A MOB, 1o, 24 SPACE,120J240V LI L2 2530 MADISON STREET <br /> MB RATING: 65,000 NC 11700 11700 VOLTAGE AMPS <br /> 98 98 AMPS <br /> A 98203 <br /> 98 MAX AMPS <br /> 122 MAX 125% <br /> SHEET TITLE <br /> ELECTRICAL ONE—LINE <br /> AND PANEL SCHEDULE <br /> SHEET NUMBER <br /> E-3 <br /> PANEL SCHEDULE NO SCALE 2 NOT USED NO SCALE 3 <br />