Laserfiche WebLink
<br />2025 FEDERAL OVERLAY, BROADWAY – CALIFORNIA ST TO 18TH ST SPECIAL PROVISIONS <br />FEDERAL AID# STBGUL-2715(012); COE PW# 3841 SP-104 May 6, 2025 <br /> <br />also contain a stranded copper drain wire and shall be individually shielded with 1 <br />an aluminum polyester foil shield. 2 <br /> 3 <br />FCNH 8-20.2(9-29.18) VIDEO DETECTION.rtf.DOCX 4 <br />9-29.18 Vehicle Detector 5 <br />Section 9-29.18 is supplemented with the following: 6 <br /> 7 <br />9-29.18(3) Video detection 8 <br />All components needed to provide a complete thermal detection system shall be 9 <br />supplied and installed per manufacturer’s recommendation. 10 <br /> 11 <br />The thermal detection equipment shall include, but not be limited to, Cameras, 12 <br />Camera Housings, Camera Lens, Camera Mounting Hardware, Video Image 13 <br />Processors, Input File Adapters, lens Adjustment Modules, Keypad and Monitor. 14 <br /> 15 <br />The thermal detection system shall be capable of supplying video detection to the 16 <br />signal controller phases as indicated in the plans. 17 <br /> 18 <br /> 19 <br />9-29.18(3)A Thermal Detection System 20 <br /> 21 <br />The thermal traffic detector sensor shall have 24 vehicle presence detection 22 <br />zones, 8 bicycle presence detection zones, 8 pedestrian presence detection 23 <br />zones, 8 traffic data detection zones, and 8 wrong way driver detection zones 24 <br />per sensor. Data zones shall collect and store vehicle counts, volume, speed, 25 <br />gap time, headway, occupancy, and classification. Data shall be time-26 <br />stamped and stored onboard (non-volatile memory) in a user selectable 27 <br />interval, from 1-60 minutes. 28 <br /> 29 <br />Data alarms are generated for: queue, inverse direction, speed drop, no 30 <br />video, and other errors. 31 <br /> 32 <br />The EDGE interface card shall be modular by design and housed in either a 33 <br />self-contained stand-alone unit or fit directly into NEMA TS1 & TS2 type racks 34 <br />as well as Type 170/2070 input files. The edge card shall be interchangeable 35 <br />between a shelf or rack mount installation without replacing or modifying 36 <br />existing units. 37 <br /> 38 <br />DIMENSIONS 39 <br />115mm x 28.5mm x 165mm – typical US EDGE rack height, dual slot 40 <br /> 41 <br />COMMUNICATIONS 42 <br />RJ 45 Ethernet 43 <br /> 44 <br />ENVIRONMENTAL 45 <br />-34°C to +74°C (-29.2°F to + 165.2°F) 46 <br />0 to 95% relative humidity – non-condensing NEMA TS2 Environmental 47 <br />compliant 48