901 91ST PL SW 2024 Plans 2025-07-16
>
Address Records
>
91ST PL SW
>
901
>
Plans
>
901 91ST PL SW 2024 Plans 2025-07-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/14/2025 1:30:33 PM
Creation date
7/14/2025 1:29:08 PM
Metadata
Fields
Template:
Address Document
Street Name
91ST PL SW
Street Number
901
Permit
B2407-048
Year
2024
Notes
NEW SFR -- MONICH 91ST SFR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTE: <br /> PROVIDE SOLID BEARING <br /> BOTH ENDS OF ALL BEARING <br /> INDEX BEAMS & GIRDER TRUSSES <br /> PACE 1 MAIN FLOOR PLAN TO THE FOUNDATION. <br /> PAGE 2 UPPER FLOOR 40'-0" <br /> PAGE 3 FOUNDATION PLAN 2021 WSEC CODE COMPLIANCE CREDITS:* <br /> PAGE 4O SECTIONS/NOTES/DETAILS 9'-0" 15-o" 16'-0" COMPLIANCE WITH TABLE 406.2 ENERGY CREDITS <br /> PAGE 4b WSEC&NOTES HEATING OPTIONS: <br /> PAGE 5 ROOF PLAN 4-HEAT PUMP 3.0 <br /> PAGE 6 ELEVATIONS <br /> ENERGY OPTIONS: <br /> GENERAL NOTES: 1.2-VERT FENS U=0.25, FLOOR R-38 1.0 <br /> 2.1-2.0 CHANGES PER HOUR Q 50 PASCALS 1.0 <br /> SIT NlA'T GTDALGZILDEAZ.DIE. 3.6-VHP ON NEEP/VCHP LIST HSPF OF 10.0 1.0 <br /> oucIT <br /> NENS"'TION TOy OD eu021EEBDIIG:°aTHE"- 6x6 POST I 5.3-TIER III WATER HEATER MIN NEE 29 20 <br /> TYP OF 2 TOTAL ENERGY CREDITS PER 406.2 8.0 <br /> NA Fi BRNA E FLDUNE RJo 11211 <br /> T Sv51EM IS <br /> 11CIT^TOE,HE IUNEISOIC ONEFOR APPROVAL *SEE PAGE <br /> WSEC <br /> (ATTACHED) FOR SPECIFICS <br /> CI Ty NG CI ASGIFIfATIDN <br /> IRC R309 <br /> K nIGH15 i0 COMPBM w/IRCw/R3p8.6 IN NI <br /> NOTES: NOTE: GO o <br /> PLANS TAKE PRECEDENCE TO DETAIL SHEETS/NOTES M <br /> zx6 E%r BID WADS®IV O.C. ALL MULTI-MEMBERS TO BE In <br /> -2 IN N WALL NSUL BATTS W/VAPOR BARRIER GLUED & NAILED W/(3)16dEXT BID-.1 <br /> "2x4 NT STUD WALLS®116"O.C.G.®NOFAGE ® 12" O.C. U.N.O. I. NO <br /> + OR <br /> B.R#2 or FURRED-0 u°BE ONEkSTORY COMET U.N.O. USE HANGARS WHERE APPLICABLE <br /> "BEAMS AND HEADERS TO BE ONE#2 DE OR <br /> 4XQ p2 DF FURRED-OUT FOR MAIN FLOOR of 9'-6" 6'-6" 1 4'-0" <br /> TWO-SiORT CONSTRUCTION U.N.O. <br /> +REFER TO ELEVATIONS FOR PLATE HEIGHTS <br /> FINEBLOG ALL PLUMBING PENETRATIONS <br /> ^PRO DE SOLD BLOCKING OVER BEAMS&BEARING I I <br /> WALLS/R502.7 <br /> +ALL HANGERS TO BE SIMPSON OR EQUAL HDU2 <br /> DENOTES DEL STUD LAMINATED TOGETHER Y' MAX. TRANSITION (2) PLACES <br /> (ARR 2 EA END THEN 12'G.C.STAGGERED __P1-6 5046 P1-6 6' S.G.D. W SAF GL P1-3 5050 5050 P1-3 <br /> (CARRIES POINT LOAD FROM R <br /> •EXHAUST VENTS TO HAVE A MAX.MA%.RUN OF 14'-0' <br /> W/NO MORE THAN TWO(2)BO's J(3)2x12 #2 HF-I (3)2x12 #2 HF-2.11 m (3)2x18 #2 HF-2.12 VENTED <br /> 1 AS FIREPLACES <br /> GENERAL <br /> (2)2x1�0 RE <br /> � I VENTED GAS FIREPLACES SHALL BE LISTED <br /> FURNACE/WATER HEATER UU IDW I IN ACCORDANCE WITH ANSI Z21.50/CSA <br /> DnE�eocTueELEOM ro BE couiPPcoE WITH THE MANUFACTURER'S INSTRUCTIONS <br /> �, r, II 2.22, SHALL BE INSTALLED IN ACCORDANCE <br /> B a <br /> W/A PRV L"PLUMBED TOFEXT.& <br /> (SSEEI&I BSTRAPS'OR BE �HKRIZER OR Ao2.a) AND SHALL BE DESIGNED AND EQUIPPED AS <br /> SPECIFIED IN SECTION G2432.2. <br /> )Nsio Ric oT wEH U oA oN PLACED ONry cS,ON G2434.2(604.2)ACCESS <br /> aioT WATER'ANiK ioABE sSED PER PANELS,GRILLES AND ACCESS DOORS THAT <br /> Mc 7RE11VER RATE m GAL PER HR) ARE REQUIRED TO BE REMOVED FOR <br /> �.A.0 IVHIT 0 COMPLY w/THE w.S.E.C. <br /> Z NORMAL SERVICING OPERATIONS SHALL NOT <br /> LABELED wNRIERS A D S."NES TO GO oo W B R K FS T - BE ATTACHED TO THE BUILDING. <br /> GO <br /> NHFOME'A <br /> D W1EN LOCATED I'FACTN ~ (, FAMILY <br /> x G2435.1 (605.1)GENERAL <br /> THE GARAGE. � 'O VENTED GAS FIREPLACE HEATERS SHALL BE <br /> INSTALLED IN ACCORDANCE WITH THE <br /> MANUFACTURER'S INSTRUCTIONS,SHALL BE <br /> STAIRWAYS/AARnCoBTM Y LISTED IN ACCORDANCE WITH Z21.88/CSA <br /> AN HA N AN <br /> 7r 38'URINE&A tD MIN,O EAD, 2 33 D SHALL CI DESIGNED ED D <br /> IANDRAIL H H uL o EQUIPPED AS SPECIFIED IN SECTION <br /> CLO E USABLE Is ACEia NDERSTAIsfi , <br /> UNDER N w * HOUSE VENTILATION SYSTEM IS G2432.2. <br /> S'ALLHAVE N TO BE INTEGRATED WITH THE HVAC <br /> eE6 vnix;jzG.weFAGEs. SYSTEM, IT WILL BE UNBALANCED <br /> 'HEADROOM fioigNioz3i'z'2 5'-6" 5'-8" 4'-0" 3'-8" 3'-7" CO AND INTERMITTENT PER M1504/1505 '° <br /> °DiNeVAFN"E En°rvosa'c or L ss 2)2x6#2 H 2.7 4X6#2 HF-2.8 3 SEE NOTES PAGE 4b. <br /> PROWNO�DED ON°T NOT MORE DiAN STNR I SOLID RISERS R31B7.5.3 O <br /> 24 CLOSET I <br /> iex2a a ❑ (2)2x6#2 HF-2.7 <br /> GARAGE FIRE SEP./R302.5/e M - a LJ <br /> N C.S. D_ 7Ya MAX STEP <br /> "SEE AL50 TABLE R302.6 FOR UP <br /> SPECIFICS aj W PANTRY V.T,p.S 26 26 L40� LL **ALTHOUGH FURN <br /> ^GAR CE/RESIDENCE COMMON WALL TO S SHOWN-A HEAT <br /> _ <br /> BE i/2-G.W.B.G.W.B TO RUN FROM ;O I L <br /> FOUNDATION TO ROOF SHEATHING <br /> "2- to _U_ O PUMP IS TO BE <br /> BTORY CEILING,STRUCTURAL BEAMS,& P D R <br /> GO <br /> PasTs TOBE covERED w/s/B'TYPE'x' SHELVES sD -�- N 2 OPTIONLL2ED PER R406.2 <br /> +1/2 TMPE'X'G.W B.IS TO BE APPLIED <br /> TO THE GARAGE SIDE OF CONSTRUCTION. -�- N <br /> +A NIGHT FITTNG SOLID-CORE DOOR <br /> 1 3/8'THICK,OR A TIGHT FITTING DOOR 1 N IIII N <br /> W/2G MIN.FIRE RATING SHALL BE USED, <br /> STEEL BOLLARD <br /> (TO BE SELF-CLOSING OR AUTOMATIC DOOR). U III U GO <br /> *ALL FUEL FIRED _ <br /> TUB & SHWR NOTES oo eD' BE APPLIANCES <br /> FOR <br /> O .-�N la <br /> FREsrOP Tubs&1.1T ooTMii `r°z MIIIBU <br /> 1'-`Tesoee ninrcelnL uP 6'-0- L.U.L. COMBUSTION FROM ANGO <br /> WHIP.GWIS BACKING OR EO. LL OUTSIDE SOURCE IFGC 304 SO <br /> N..30*0&1024 NQ.IN.MIN. - �a DO o a IIII GARAGE o a <br /> CLOSURES TO BE SAFETY GLASS U U <br /> GF LIVING a 'III IIII 386 SO FT INT. <br /> BEHIND WIRPRF GWB®EXTT WALL <br /> M N} NIII N <br /> SHEARWALL SCHEDULE N <br /> UP 16R **R309.6.2 PROVIDE A IIII <br /> P1-6 7/16" OSB W/Sd O 6" O.C. EDGES ENTRY DEDICATED CIRCUIT IN <br /> 2x BOUNDARY MEMBERS 12" O.C. FIELD III GARAGE FOR EV CHARGING IIII <br /> 5/8" A.B.'s ®48" O.0 LTP5 ®24" O.C. p <br /> 7/1 <br /> 16" OSB W 8d ®3" O.C. EDGES (3)2x10 #2 HF-2.4 soya 3 sv/cL <br /> P1-3 / / 22x6-2.6 IIII 3x BOUNDARY MEMBERS 12" O.C. FIELD P2_3 - <br /> 5/8" A.B.'s @ 36" O.0 LTP5 ®12" O.C. 6050 P2-3 1060 1060 16'x8' O.H. GARAGE DR <br /> P2-3 7/16" OSB W/8d ®2" O.C. EDGES o HDU2 4x12 WIND STRUT RIM 51Sx18 24F-V4 GLB-2. <br /> 3x BOUNDARY MEMBERS 12" O.C. FIELD COVERED PORCH III IIII -1-31 <br /> 5/8" A.B.'s ®12" 0.1 LTPS ®6" O.C. (2) PLACES p1_3 <br /> FLOOR: 3/4" COX W/10d ®6" O.C. EDGE 12' FIELD 6x8 #2 DF-2.1 TYPICAL PORCH III- ------ - - HDU4 <br /> jE _- SOFFIT& IIEL (4) PLACES <br /> ROOF: 7/16" OSB W/8d ®6" O.C. EDGE 12" FIELD o 6x6 POST LINE OF UPPER TEVEL%CANT <br /> WOOD NAILS/ BOLT <br /> STRAPS MEMBERS BOLTS EMBED TYP OF 4 <br /> MST37 (2)2x 22-16d <br /> 7�a'MAX STEP <br /> HOLDOWNS <br /> HDU2 (2)2x SB5/8x24 18 INSMALLEDER <br /> HDU4 2)2xSIEI24 18" 2'-10" 9'-4" S-7" SPECS AND RC R31G4 <br /> WBATTERY . <br /> SD <br /> BACKUP <br /> 11'-0" 8'-4" '-OY2' 16'-3" '_42" (INTERCONNECT) <br /> CARBON MONOXIDE ALARM <br /> CO <br /> INSTALLED PER MFG. <br /> 18'-10" 21'-2" SPECS AND IRC R315 <br /> (INTERCONNECT) <br /> 40'-0" INSTALLED PERC MFG.O <br /> SPECS AND IRC R314 <br /> (INTERCONNECT) <br /> MAIN FLOOR PLAN SCALE: 1/4"=V-O" <br /> 998 SQ.FT. MAIN <br /> 1352 SQ.FT.UPPER <br /> 2350 SQ.FT.TOTAL �N <br /> A I HOEDOWNS, FRAMING 404 S0.FT.GARAGE <br /> CALL ANCHORS AND SHEARWALLS <br /> MUST BE INSPECTED BEFORE COVERING <br /> LOT LOCATION: <br /> 901 91ST PLACE SW <br /> EVERETT, WA 98204 <br /> PLAN 2350 <br /> FOR: <br /> THESE PLANS MAY NOT BE REPRODUCED V L A D M O N I C H <br /> WITHOUT SPECIFIC PERMISSION OF <br /> FAWN CREEK DESIGN,TONASKET,WA. <br /> DESIGNERS LIABILITY TERMINATES UPON 8829 5TH AVE W EVERETT,WA 98204 <br /> ISSUANCE OF BUILDING PERMIT.IT IS THE 425-508-7521 <br /> OWNER AND BUILDERS RESPONSIBILITY TO FAWN CRF.F.K T)FSTGN <br /> CONFIRM ALL DIMENSIONS ON-SITE AS DRAWN: 02-16-22 <br /> WELL AS COMPLIANCE WITH ALL 429 Pine Creek Road BY: MORGAN OF <br /> GOVERNING CODE REQUIREMENTS. CAI <br /> Tonosket, WA, 98855 <br /> 406-916-9888 REVISED: <br />