Laserfiche WebLink
NOTE: <br /> PROVIDE SOLID BEARING @ <br /> BOTH ENDS OF ALL BEARING <br /> BEAMS & GIRDER TRUSSES <br /> TO THE FOUNDATION. <br /> r- LINE OF LOWER LEVEL <br /> II <br /> I <br /> I � <br /> I I <br /> I I <br /> 40,_0.. I <br /> 11'-6" 14'-4" 14'-2" <br /> NOTES. <br /> 216 EXT STUD WALLS®16"O.C. <br /> P1-6 5040 7� _ <br /> -6 6040 P1-6 7040 Pi-6 +R-21 IN WALL WELL BATTS W/VAPOR BARRIER <br /> +BEAMS AND HEADERS TO BE 6.8 p2 IF OR <br /> 4.8 b2 OF FURRED-OUT U.N.O. <br /> +REFER TO ELEVATIONS FOR PLATE HEIGHTS <br /> (2)2%10 #2HF-1.3 (3)2x10 #2 HF-1.4 SITE) #2 DF-1.5 +FIREBLOCN ALL PLUMBING PENETRATIONS <br /> BEGROOM EGGRE55/R31 G-1: PROv1DE Soup BLOCKING OVER BEAMS&BEARING <br /> WALL AN 502.7 <br /> SILL Hi 44 OR LESS ABV FIN FLR HANGERS TO BE SIMPSON OR EQUAL <br /> MIN NET OPN'G TO BE 5.)50 FT W/ •®DENOTES OBL STUD LAMINATED TOGETHER <br /> MIN WIDTH HO MIN HEIGHT /I6d 2 EA END THEN 12'O.C.STAGGERED <br /> NHEN SILL IS OVER 6'-0'O8V GRME SILL MUST (CARRIES POINT LOAD FROM ABOVE) <br /> BE MIN 24"ABV FIN FLR R312.2.1 'INSULATION BAFFLES®EAVES TO EXTEND 6'ABOVE <br /> BATTS®12"ABOVE BLOWN INSULATION <br /> gpRM #4 <br /> STAIRWAYS/I.R.C. R311.7 <br /> +TxE MAxIMUM STAI RISER xENMi SXALL BE <br /> 34 MAX,RISE&a 10' <br /> °FHANDRAIL HEAD <br /> r1N2 sr"" <br /> AIRS <br /> LOFT M SUITE �U_HA EREGW R5UR ES. <br /> 'EN <br /> SOFFITS <br /> Op Mt/2'GIB <br /> AC <br /> 7-$ IS <br /> 'THE IADIUS OF THE CU <br /> NCE/R311.�.3 <br /> WHOLE HOUSE +FIRE STOP 6FaIR60/R602.gN3 E2 tihl2 <br /> FAN - 75CFM-SEE No CRCAii VAN B/,6 Ea NosiHc BET LESS <br /> TABLE M1507.3.3(1) cRROT 3/1ED BUTTNOT NO E TR sailo/4'SHAULRS BE <br /> s�elroLD sD CONNECTED TO SD <br /> In CLOSET TIMER IRC 1507.3 <br /> Qlo <br /> 41" TUB&SHWR NOTES <br /> FIRESTOP TUBS&SxWRS 302A1 <br /> N --- - --- 1 ONE RATED PER WSEC awa AREA IA HE <br /> sMoow <br /> S&P •GUARDRAIL+36°HIGH PER R312 AREA MATERIAL UP 6'-0' <br /> INTERMEDIATE RAILS SHALL BE wH W.P.OWN BACNwc OR E0. <br /> PLACED SO THAT A 4"0 SPHERE 3'-4" 2'-6" 3'-4" 8'-4" I s s:3o o&10 <br /> 2 <br /> 4 so.w.M <br /> CANNOT PASS THROUGH THEM, ErvcLosuREs ro BE SAFETY CLASS <br /> SHOWER FLOW RESTRICTOR 2.5 GPM <br /> o c Q CLEAR PLEXIGLASS OR EQUIV vAPOR BARRIER NOT PERMITTED <br /> _SCISSOR BEHIND WTRPRF GWH®E%T WALL <br /> N m T '24 DN 15R HVAC FLA <br /> 17 al V�s BATH25 <br /> O �d Ii 22x30 i T�� <br /> N L' A GJ1S iV`�6 T <br /> --- --- LAUNDRYINENCLOSET v �x o <br /> s-BIFOLo DRYER ASH Q <br /> V.yp.s o <br /> 7,_8" m N a <br /> SD 23 L6 S&P v.T <br /> SD N ---- ---- ® l�1 34x7 I <br /> SD CLOSET I <br /> soBlFan I a <br /> ZZ I I <br /> BDRM #J -CLOTHES DRYERS WITH MORE <br /> THAN 200CFM EXHAUST REQUIRE <br /> A 100 SO IN OPENING,ROR <br /> E HW 110 <br /> OPEN MAKE UP AIR IS TO BE Ia <br /> Oo PROVIDED PER IMC 504 24 <br /> BDRM #2 <br /> I <br /> al �a o <br /> (z)zx W.T.C. <br /> lo #z HF-1.1 (z)zx6 #z HF-1.z �I <br /> P1-6 5040 - <br /> MST37 _________, SHEARWALL SCHEDULE <br /> o (2) PLACES T S&P T P1-6 7/16" OSB W/8d @ 6" O.C. EDGES <br /> 21 BOUNDARY MEMBERS 12" O.C. FIELD <br /> L_ LINE OF LOWER LEVEL 1-65040 Pi 5/8" A.B.'s @ 48" O.0 LTP5 @ 24" O.C. <br /> 5040 Pi-6 <br /> P1_3 7/16" OSB W 8d @ 3 O.C. EDGES <br /> 3x BOUNDARY MEMBERS 12" O.C. FIELD <br /> 5/8" A.B.'s @ 36" O.0 LTP5 @ 12" O.C. <br /> ————— MST37 P2-3 7/16" OSB W/8d @ 2" O.C. EDGES <br /> (4) PLACES 3x BOUNDARY MEMBERS 12" O.C. FIELD <br /> 5/8" A.B.'s @ 12" O.0 LTP5 @ 6" O.C. <br /> SMOKE DETECTOR FLOOR: 3/4" CDX W/10d @ 6" O.C. EDGE 12" FIELD <br /> 3"-4" 2'-0" 3'-3" 2"-9' INSTALLED PER MFG. SD ROOF: 7/16" OSB W/8d @ 6" O.C. EDGE 12" FIELD <br /> SP CS AND IRC R314 <br /> 7'-8" WOATTERY BACKUP STRAPS MWOOD RS BOLT EMBED(IBOLT <br /> NTERCONNECT) <br /> 18'-10" 11'-8" 9'-6'" INSTALLED MONOXIDE MFG. CO HOEDOWNS (2)2x 22-16d <br /> SPECS AND IRC R315 <br /> 40'-0" (INTERCONNECT) HDU2 (2)2x SB5/8x24 181" <br /> HDU4 (2)2x SB5/8x24 18" <br /> UPPER FLOOR PLAN SCALE: 1 4"=1'—O" <br /> FAWN CREEK DESIGN <br /> 429 PINE CREEK ROAD OF <br /> TONASKET, WA 98855 [2 <br /> 509-486-1988 <br />