Laserfiche WebLink
GENERAL NOTES-DEMOLITION PLAN FREIHEIT <br /> 1.PRIOR TO DEMOLITION,GENERAL CONTRACTOR TO VISIT THE SITE AND VERIFY EXTENT OF ARCH ITECTURE <br /> DEMOLITION ACTIVITIES REQUIRED FOR NEW CONSTRUCTION <br /> 2.REMOVE ALL DEBRIS AND GARBAGE PRIOR TO START OF CONSTRUCTION.REPAIR SUBSTRATES AS <br /> RQUIRED FOR NEW FINISHES <br /> 3.COORDINATE CONSTRUCTION SCHEDULE WITH ARCHITECT AND BUILDING OWNER TO MINIMIZE <br /> DISRUPTIONS TO BUSINESS HOUR OPERATIONS <br /> 4.THE CONTRACTOR SHALL ENSURE THAT THIS PROJECT AND ALL CONSTRUCTION ACTIVITIES RELATED <br /> THERETO CONFORM WITH ALL LOCAL,REGIONAL,STATE AND/OR FEDERAL REGULATIONS PERTAINING <br /> TO DISTURBING,DISPLACING,AND/OR REMOVAL OF ASBESTOS OR ASBESTOS CONTAINING MATERIALS. <br /> NOTE SPECIFICALLY THAT FOR PROJECTS IN WASHINGTON STATE,THE CONTRACTOR SHALL CONFORM <br /> TO THE REQUIREMENTS OF THE PUGET SOUND AIR POLLUTION CONTROL AGENCY REGARDING <br /> INSPECTION,CERTIFICATION,AND NOTIFICATION <br /> 5.ALL SALVAGED ITEMS SHALL BE RETURNED TO BUILDING OWNER AT OWNER'S OPTION.ALL <br /> UNWANTED MATERIAL SHALL BE DISPOSED OF PROPERLY <br /> 6.DEMOLISH ALL EXISTING IMPROVEMENTS AND FIXTURES AS NECESSARY TO ACCOMMODATE NEW <br /> WORK <br /> 7.PROTECT ALL AREAS OF BUIDLING AND HVAC SYSTEM FROM DUST AND DEBRIS AT ALL TIMES; <br /> PROTECT ANY ITEMS TO REMAIN AGAINST DAMAGE DURING CONSTRUCTION <br /> 8.ALL ABANDONED FASTENERS AND ANCHORS SHALL BE REMOVED FROM ALL WALL SURFACES,AND J <br /> WALLS TO BE PATCHED/REPAIRED AS NECESSARY w <br /> 9.ALL DEMOLISHED AND UNUSED CABLE AND WIRING TO BE DEMOLISHED BACK TO SOURCE Q <br /> 10.DEMOLISH ALL ELECTRICAL AND PLUMBING WITHIN DEMOLISHED WALLS.REROUTE UTILITIES IN NEW 0 <br /> OR REMAINING WALLS PER FLOOR PLAN C <br /> 11.DEMOLISH FLOORING AND WALL BASE THROUGHOUT EXISTING SHOWROOM,UNLESS NOTED W <br /> OTHERWISE.PREP TO RECEIVE NEW FLOOR MATERIALS ^' <br /> 12.DEMOLISH EXISTING CEILING GRID,ACOUSTIC TILES,GWB CEILINGS&SOFFITS,AND LIGHTING W <br /> THROUGHOUT EXISTING SHOWROOM AND FIRST FLOOR OFFICES,UNLESS NOTED OTHERWISE ON THE <br /> REFLECTED CEILING PLAN. <br /> 13.EXISTING WINDOW TREATMENTS TO REMAIN.CONTRACTOR TO REMOVE PRIOR TO DEMOLITION, Cl) <br /> CLEAN,AND REINSTALL AFTER ALL WORK IS COMPLTED,UNLESS NOTED OTHERWISE <br /> r) <br /> KEYNOTES-DEMOLITION FLOOR PLAN z <br /> Q <br /> FD-01 EXISTING STOREFRONT TO BE DEMOLISHED IN PREPARATION FOR NEW CONSTRUCTION; <br /> SEE SHEET A3.04 FOR ADDITIONAL INFORMATION. <br /> FD-02 EXISTING DOORS,FRAMES,AND ASSOCIATED HARDWARE TO BE DEMOLISHED,VERIFY O <br /> POSSIBLE REUSE OR SALVAGE WITH OWNER;SEE SHEET A3.04 FOR ADDITIONAL <br /> INFORMATION. O <br /> FD-03 REMOVE EXISTING CASEWORK.PATCH AND REPAIR WALLS AND FLOOR AFFECTED BY 0 } <br /> DEMOLITION AS REQUIRED. <br /> FD-04 REMOVE PORTIONS OF EXISTING SHOWROOM TO ACCOMMODATE NEW SHOWROOM > MO <br /> CONSTRUCTION-EXTENTS INDICATED BY HATCH PATTERN;SEE SHEET A3.04 FOR <br /> ADDITIONAL INFORMATION. O Z N <br /> FD-05 REMOVE EXISTING EXTERIOR FACADE FINISH,DOWN TO STUDS,PROTECT WALLS FOR <br /> S GE (E)OFFICE FD-02 NEW CONSTRUCTION;SEE SHEET A3.04 FOR ADDITIONAL INFORMATION. v= W C) <br /> — <br /> (E)IT NEW <br /> REMOVE NON-STRUCTURAL INTERIOR WALLS TO EXTENTS SHOWN,PATCH AND REPAIR ! ) <br /> TORA AS REQUIRED. Q <br /> �J L211= —L204--]- — (N)TECH FD-07 EXISTING STEP AND ASSOCIATED HANDRAILS TO BE REMOVED IN PREPARATION FOR NEW <br /> -_d BREAK ROOM SHOWROOM CONSTRUCTION;SEE SHEET A3.04 FOR ADDITIONAL INFORMATION. <br /> L201 FD-08 REPLACE EXISTING EXIT DOOR AND FRAME,SEE SHEET A3.04 FOR ADDITIONAL 0 FD-1 INFORMATION. w <br /> E HALL FD-09 REMOVE EXISTING OVERHEAD DOOR AND ASSOCIATED HARDWARE.PREP OPENING FOR Z > W <br /> — — — - — — — — — — — 200::] (E)STORAGE — — — — INFILL. w Lu <br /> C20371 FD-10 REMOVE EXISTING SECURITY DOOR/GRATE AND ASSOCIATED HARDWARE.PREP � CV w <br /> OPENING FOR INFILL. CD > <br /> FD-12 REMOVE RELIGHTS.PREP OPENING FOR INFILL. = r Lu <br /> FD-13 REMOVE EXISTING FLOORING AND WALL BASE THROUGHOUT.REPAIR SUBSTRAIT TO <br /> (E)STORAGE PREP FOR NEW FINISH. <br /> 210 (E)OFFICE (E)OFFICE FD-14 EXISTING COLUMNS TO REMAIN,PROTECT THROUGHOUT CONSTRUCTION. <br /> L208a C207� FD-15 GOODNG FIRE RISER TO CONDITION AND PAINTED,PROTECT THIFY FIRE RISER CAGE TO BE ROUGHOUT CONSTRUCTION.RBOUGHT TO <br /> (E))OFFICE (E))OFFICE I FD-16 EXISTING SERVICE BAYS TO RECIEVE NEW CONCRETE SEALER,PREP EXISTING <br /> C206� C205� CONCRETE FLOOR FOR NEW FLOOR FINISH.VERIFY WITH OWNER SCHEDULE FOR <br /> — — — — PHASED FLOOR PREP. <br /> FD-17 REMOVE EXISTING EMBEDDED ALLIGNMENT EQUIPMENT,VERIFY WITH OWNER SALVAGE <br /> OR RE-USE. <br /> FD-18 REMOVE EXISTING SINK,FACUET AND ASSOCIATED PLUMBING.PREP AREA FOR NEW <br /> PLUMBING FIXTURES PER A3.05. <br /> FD-05 L FD-19 REMOVE EXISTING RESTROOM PLUMBING FIXUTRES,REWORK PLUMBING FOR NEW <br /> TYP LAYOUT,SEE A3.05 FOR ADDITIONAL INFORMATION. <br /> FD-20 REMOVE EXISTING FINISHES THROUGHOUT RESTROOM,INCLUDING BUT NOT LIMITED TO <br /> FD-21 FLOORING,WET-WALL FINISHES,TOILET PARTITIONS,LIGHTING AND PLUMBING FIXTURES. <br /> SHOWROOM BELOW TYP SEE A3.05 FOR ADDITIONAL INFORRAITON. <br /> �l FD-21 REMOVE EXISTING STOREFRONT WINDOWS AND PREP OPENING FOR INFILL. <br /> R <br /> EGISTERED <br /> I I I I I I I I I I I LEGEND-DEMOLITION PLAN 12733 <br /> ARCHITECT <br /> NO WORK THIS AREA <br /> EXTENTS OF EXISTING SHOWROOM MICHAEL J. L TON <br /> DEMOLITION STATE OF WASHINGTON <br /> EXISTING CONSTRUCTION/ <br /> ELEMENT TO REMAIN <br /> EXISTING CONSTRUCTION/ <br /> --- ELEMENT TO BE REMOVED ISSUE LIST <br /> — — — — — — — — — — — — — — — — — — — — — — — — PERMIT SUBMITTAL 03.31.2022 <br /> PRICING UPDATE 08.09.2022 <br /> 1 BLDG REVISION 09.30.2022 <br /> 2 PW REVISION 10.04.2022 <br /> o— — — — — — — — — — — — — — — — — — — — — — — — — — — 3 PLANNING/PW REVISION 11.23.2022 <br /> I I I I I I I I I I I I <br /> 8 <br /> DEMOLITION SHOWROOM 2ND FLOOR PLAN 6 4 6 16 <br /> 1 B DEMOLIITION <br /> A3.01 <br /> Scale:1/8"=V-0" <br /> SHOWROOM 2ND <br /> FLOOR PLAN <br /> A3.01 <br />