My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7800 EVERGREEN WAY HYUNDAI 2025-08-22
>
Address Records
>
EVERGREEN WAY
>
7800
>
HYUNDAI
>
7800 EVERGREEN WAY HYUNDAI 2025-08-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2025 8:31:28 AM
Creation date
7/17/2025 11:29:27 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7800
Tenant Name
HYUNDAI
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
120
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NEW PYLON POLE TO METAL FLAGPOLE, FREIHEIT <br /> ACCOMMODATE SEE SPECIFICATIONS <br /> NEW SIGNAGE DESIGN MATCH CONCRETE PER 121A2.03 FLAGPOLE COLLAR BARRIER FREE BARRIER FREE <br /> EXISTING SIGN STRICTURE PROVDE BLOCKING,AS PARKING SIGN PARKING SIGN ARCHITECTURE <br /> 1"R TOOLED REQUIRED <br /> EDGES,TYP. LANDSCAPE AREA BEYOND, <br /> PER LANDSCAPE <br /> DRAWINGS <br /> EXISTING PYLON FLAG TYPE Iw-III=III= SECTION 4.6.4 OF THE ADAAG STANDARDS REQUIRES EACH VAN ACCESSIBLE PARKING AISLE IS ALSO <br /> - - I � <br /> -III= .� • - -III- EACH ACCESSIBLE PARKING STALL TO BE IDENTIFIED REQUIRED TO BE IDENTIFIED WITH A SIGN WITH <br /> SIGN STRUCTURE TO REMAIN. WITH VERTICAL SIGNAGE-SEE DETAIL 5/A2.20 FOR THE TEXT,"VAN ACCESSIBLE"MOUNTED BELOW <br /> ADDITIONAL DETAILS. THE ISA.IT IS REQUIRED THAT A SIGN BE USED <br /> it I III= = = = TO DESIGNATE EACH VAN ACCESSIBLE PARKING <br /> wz JIL--IIII IIII��III <br /> o = III THE SIGN DESIGNATING THE PARKING STALL AS STALL.CAN PARKING STALLS SHALL BE <br /> COMPACTED SAND PER =III ACCESSIBLE MUST DEPICT THE INTERNATIONAL PERMITTED TO BE 96"MINIMUM IN WIDTH <br /> o c f III-III-III SYMBOL OF ACCESSIBILITY(ISA).THE SIGN MUST WHERE THE ADJACENT AISLE IS 96"MINIMUM IN <br /> Qz FLAGPOLE MFGR = = L-III= <br /> LL RECOMMENDATIONS - -I 4"COMPACTED LAYER OF ALSO USE TEXT TO IDENTIFY THE SPACE AS WIDTH PER SECTION 502.2 OF ICC a117.1-2009 <br /> zR <br /> III- APPROVED SUBGRADE RESERVED. <br /> r; <br /> m z a -III-II <br /> III-III- MATERIAL THE VERTICAL SIGNAGE IS REQUIRED IT IS RECOMMEND THAT THE U.S.DEPT.OF REMAIN VISIBLE WITH A VEHICLE PARKING IN <br /> FOUNDATION SLEEVE, -PER FLAGPOLE TRANSPORTATION STANDARD R7-8 SIGN BE THE SPACE.IT IS RECOMMENDED THAT THE <br /> w III - <br /> > MANUFACTURER MOUNTED IN FRONT OF AND CENTERED ON THE i BOTTOM EDGE OF THE LOWEST ADAAG <br /> *NOTE:ALL SIGNAGE UNDER _ 11 � INSTALL BASE PER MFGR. PARKING STALL. PAINTED STALL REQUIRED SIGN BE MOUNTED @60"ABOVE <br /> J RECOMMENDATIONS q STRIPE TYP. FINISH GRADE.THE PARKING SIGNAGE MAY <br /> SEPERATE PERMIT z STATE AND LOCAL CODES MAY HAVE VARYING ALSO BE MOUNTED ON A WALL OR BUILDING. <br /> cz7 FLAGPOLE BASE PLATE AND REQUIREMENTS.SOME STATE OR LOCAL CODES J <br /> EMBEDDED SPIKE,PER REQUIRED AN ADDITIONAL SIGN THAT INDICATES A IT IS RECOMMENDED THAT THE HORIZONTAL <br /> MANUFACTURE FINE AMOUNT FOR PARKING GIN THE RESERVED DIMENSION FROM THE SIGN PLACEMENT TO THE W <br /> w RECOMMENDATIONS STALL WITHOUT PARKING REGISTRATION.FINE PAINTED SYMBOL PAINTED SYMBOL FRONT OF THE SPACE BE 60"OR LESS.IF THE 0 <br /> z NOTE: AMOUNT MAY VARY. PER 71A2.20 PER 71A6.00 SIGN IS LOCATED WHERE IT COULD BE <br /> EXISTING SIGN O EXTERIOR FLAGPOLE TO BE A DEFERRED SUBMITTAL.PRIOR TO INSTALLATIONS OF EXTERIOR DAMAGED BY VEHICLES,ABOLLARDOROTHER O <br /> BASE LANDSCAPING FLAGPOLE,THE FOLLOWING MUST BE SUBMITTED TO CITY OFBOTHELL: PROTECTION IS RECOMMENDED. <br /> TO BE REWORKED ¢ SHOP DRAWINGS(PLANS&DETAILS) 11 I <br /> -STAMP&SIGNED CALCULATIONS I W <br /> -SPECIFICATIONS l/1w/1, <br /> -ANY OTHER REQUIRED DOCUMENTATION REQUIRED BY THE C OF BOTHELL <br /> 10 VAN W <br /> UPGRADED PYLON SIGN SECTION FLAGPOLE BASE DETAIL <br /> A6.00 / A6.00 1 <br /> Scale:118"=V-0" Scale: I-. 9'-0'MIN. 5'-0'MIN, 8'-6'MIN. Q <br /> 1.5%MAX SLOPE IN ANY DIRECTION 7 <br /> PER MANUFACTURER L <br /> GALVANIZED ROUND 1 BARRIER FREE STALL STRIPING <br /> PIPE PER MANUF., <br /> PAINTED SW4056- A6.00 BLUEPRINT Scale:1/4"=1'0" O <br /> w CD <br /> O zN <br /> 00 <br /> - 12'k 18'M.U.T.C.D.REGULATORY 2 w CY) <br /> SIGN#P4-C6(MODIFIED)GREEN& !/)BLUE ON WHITE,REFLECTORIZED v <br /> DISABLED "VAN ACCESSIBLE"PLACARD TO I <br /> PA IKG BEINSTALLED WHERE Q W <br /> INDICATED <br /> 1.5%MAX SLOPE IN ANY DIRECTION - z LL.I LU <br /> AN <br /> �U�� Lu <br /> ;I A_CEss3LE N LLJ <br /> — 0 4 BARRIER FREE STALL STRIPING <br /> -u FOOTING SIZEIANCHORING a 6"x 12"M.U.T.C.D. = r LL.I <br /> - - PER MANUFACTURER j . A6.00 REGULATORY <br /> - Scale:1/4"=1'-0" SIGN#P3.8C(MODIFIED)BLUE <br /> ANCHOR POINT z ON WHITE,REFLECTORIZED <br /> WALL ASSEMBLY <br /> PER SECTION NOTE: v <br /> PROVIDE LOOPS FOR(5)BIKES ELECTRICAL <br /> COATING <br /> IC <br /> COATING EMBEDDED 5 LOOP BICYCLE RACK /'► <br /> WATERPROOFING 8 CHARGING 2"DIA.-3LBS./L.F.GALVANIZED <br /> - STEEL CHANNEL POST <br /> SYSTEM A6.00 Scale:3/4"=1'-0" STOP <br /> FINISHED GRADE <br /> CONCRETE SLAB PER NOTE: <br /> a STRUCTURAL TO PAINT LETT�NGE HIGHWAY PAINT VISITOR <br /> z . <br /> FOOTING PER STRUCTURAL <br /> COMPACTS&- <br /> L PE RESERVED <br /> SO �y <br /> . _ 7aa <br /> iz <br /> VAN STALL <br /> REGISTERED <br /> — — TRAFFIC LETTERING - <br /> TRA C <br /> ARCHITECT <br /> III III—III—III—I I <br /> — — — — <br /> EXISTING PYLON SIGN TO BE A6.00 Scale:6^=1'-0" <br /> REFACED,REWORK PER HMA AND <br /> TYPICAL BEOW GRADE CITY OF EVERETT SIGNAGE <br /> FOUNDATION WALL REQUIREMENTS. MICHAEL J. L TON <br /> _ . 2'-5 318" 3 11116" <br /> III_ ASSEMBLY PER SECTION *NOTE:ALL SIGNAGE UNDER 2'-37/8" 3118" STATE OF WASHINGTON <br /> —III III—III —III TIGHTLINE WHERE OCCURS SEPERATE PERMIT Z-31/16" 3/4" <br /> —I I —III —I —I EVERETT <br /> III—III —III—III PERFORATED FOOTING <br /> —III—III III DRAIN,DO NOT WRAP PIPE ISSUE LIST <br /> _ WITH FILTER FABRIC. <br /> III—III `,q ` ~•4 —III PLACE NEAR BOTTOM OF BARRIER FREE PARKING SIGNAGE PERMIT SUBMITTAL 03.31.2022 <br /> FOOTING WITH DRAIN 2 PRICING UPDATE 08.09.2022 <br /> 1 BLDG REVISION 09.30.2022 <br /> —III—III - HOLES ON THE BOTTOM. A6.00 2 PW REVISION 10.04.2022 <br /> Scale: -0" 3 PLANNING/PW REVISION 11.23.2022 <br /> III—III ;,, *NOTE:ALL SIGNAGE UNDER A S��owroom <br /> SEPERATE PERMIT Showroom <br /> i 12' 12" 12" <br /> — SsMae <br /> 41 <br /> EXTEND CURB TO ACCOMODAI E <br /> \ / — ER SIGN BASE <br /> ik <br /> II a III <br /> NOTE:USE WHITE HIGHWAY PAINT TO PAINT ARROW <br /> 11 FOUNDATION y UPGRADED PYLON SIGN DIRECTION SIGNAGE 3 DIRECTIONAL ARROW <br /> A6.00 Scale:3"=T-O" A6.00 NOT TO SCALE A6.00 ,Scale:1"=1'-0" A6.00 Scale:1 = `' SITE DETAILS <br /> A6.00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.