B2301-001 <br /> 9227 4th Ave W <br /> Napa Homes LLC <br /> Architectural (Reviewer: Darren Chang, dchang@everettwa.gov) <br /> 1. The separation wall between the two dwelling units should be 1-hour fire-resistance rated. <br /> This wall should be the wall separating the two storages in the middle. This wall assembly <br /> should extend from the foundation to the underside of the roof sheathing. Openings in this <br /> wall, if any, should be equipped with not less than a 45-minute fire-rated door assembly <br /> equipped with a self-closing or automatic-closing device. Please annotate the fire-resistance <br /> rating requirement in the floor plan and provide a detail of the fire-rated assembly. IRC <br /> Sections 302.3, R302.3.1, R302.3.2, R302.3.4. <br /> 2. The floor plans need to show that the egress windows'sill height is not greater than 44 <br /> inches from the finished floor on the interior. Please annotate egress windows'sill heights in <br /> the floor plan on Sheet 2/6 and 3/6 or in the window schedule on 6/6. IRC Section <br /> R310.2.3. <br /> 3. The window of the second-floor bathroom (next to the stair land) is missing window <br /> annotation. <br /> 4. The dimensions of the stair's treads & risers should be annotated in Detail 6/5 on sheet 5/6. <br /> V IRC Section R311.7.5. <br /> /5. The frost depth of the foundation footing should be 18"deep minimum. Please annotate it <br /> V in Detail 3/5 and 4/5 on sheet 5/6. IRC Section R403.1.4 and EMC 16.01.010.J. <br /> 6. Please add the crawlspace access locations and dimensions to the floor plan. IRC Section <br /> R408.4. <br /> Energy&Whole House Ventilation (Reviewer: Darren Chang, dchang@everettwa.gov) <br /> 7. The application proposes to obtain 0.5 energy credit through 2018 WSEC Table 406.3 <br /> Option 1.7, which requires advanced framing and raised heel trusses or rafters, and R-49 <br /> J . Advanced as listed in Section A102.2.1, Ceilings below a vented attic. Detail 1/5 on Sheet <br /> — 5/6 shows an attic framing detail not conforming to the"advanced framing and raised heel <br /> trusses" requirement. Please revise. 2018 WSEC Section A102.2.1. <br /> 8. The application proposes to obtain 0.5 energy credit through 2018 WSEC Table 406.3 <br /> Option 2.1 "Compliance based on R402.4.1.2: Reduce the tested air leakage to 3.0 air <br /> changes per hour maximum at 50 Pascals."To qualify for this credit, the building permit <br /> drawings need to specify the option being selected and the maximum tested building air <br /> leakage, and show the qualifying ventilation system and its control sequence of operation. <br /> Please supply this information. 2018 WSEC Table 406.3. <br /> /9. The application proposes to obtain 1.5 energy credits through 2018 WSEC Table 406.3 <br /> / Option 3.5.1 "Air-source, centrally ducted heat pump with minimum HSPF of 11.0."The <br /> OJ 3200 Cedar Street © 425.257.8810 0 permitservices@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 2 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.