Laserfiche WebLink
(E) POTTER PAD 1 00-D I M <br /> The Symbol of Protection Dual Input Module <br /> Features Q5S�MB�Fo <br /> • Single module with dual contact monitoring inputs « <br /> • Two(2)Class B or one(1)Class A monitoring inputs i . Q <br /> • SLC Class A,Class X&Class B A 2 THE V� <br /> • Mounts in a standard 4"or double gang box <br /> • Wiring terminals accessible when mounted in box J <br /> • All wiring terminals accept 22 to 12 AWGR <br /> • Product includes a 5 year warranty ..... <br /> • UUKL Listed for Smoke Control <br /> NOTE:This addressable module does not support 2-wire smoke <br /> detectors. <br /> F M � U <br /> APPROVED <br /> Description Technical Specifications <br /> The PAD100-DIM uses one (1) SLC loop address when monitoring Operating Voltage 24.OV <br /> two(2)Class B circuits or one(1)Class A circuit.The module mounts <br /> on either a 4" square or double gang box. The module is capable Max SLC Standby 240µA <br /> of monitoring two (2) separate class B circuits making it ideal for Current <br /> monitoring sprinkler waterflow and valve tamper switches when they Max SLC Alarm 240µA <br /> are located in the same proximity.The PAD 100-DIM includes one red Current <br /> LED to indicate the module's status. In normal condition, the LED Max Wiring Resistance 100 S2 <br /> flashes when the device is being polled by the control panel.When an of IDC <br /> input is activated,the LED will flash at a fast rate. Max Wiring 1 µF <br /> Capacitance of IDC <br /> Application EOL Resistor 5.1KD <br /> The PAD 100-DIM is compatible with Potter's IPA and AFC/ARC Operating Temperature 32 to 120°F(0 to 49°C) <br /> series addressable fire alarm control panels. The PAD100-DIM is an Range <br /> interface module used to monitor dry contact devices such as sprinkler Operating Humidity 0 to 93%(non-condensing) <br /> waterflow, valve tamper switches, or conventional pull stations. The Range <br /> module is capable of monitoring two separate Class B or one Class A Max no.of Module Per 127 units <br /> circuits. Loop <br /> SettingtheAddress 4.17"(106mm)L x 4.17" <br /> Dimensions (I06mm)W x 1.14"(29mm)D <br /> Each addressable SLC device must be assigned an address. The Standard 4"Square or <br /> address is set using the DIP switch located on the PAD 100-DIM.When Mounting Options Double Gang Box <br /> the PAD 100-DIM is used to monitor two individual Class B circuits Shipping Weight 0.6 lbs <br /> a single device address is assigned, each input is then identified as a <br /> sub-point of the module address. For example,if the address number <br /> is assigned as"8", the first input will be "8.1" and the second input <br /> will be"8.2". <br /> Before connecting a device to the SLC loop, take the following <br /> precautions to prevent potential damage to the panel or device: <br /> 1. Power to the device is removed. <br /> 2. Field wiring is correctly installed. <br /> 3. Field wiring has no open or short circuits. <br /> Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br /> 8830082-REV D 12/18 PAGE 1 OF 2 <br />