Laserfiche WebLink
GENERAL NOTES <br /> WET SYSTEM 1. ALL GROOVED COUPLINGS TO BE RIGID UNLESS NOTED(III)WHICH ARE FLEXIBLE. <br /> AREA AREA NUMBER OF 2. ALL STEEL PIPE TO BE AS FOLLOWS: <br /> DESCRIPTION SQ.FOOTAGE SPRINKLERS <br /> STEEL PIPE ASTM E-53/ASTM A-795 OR BETTER <br /> A 12;DI 12"DI SYS 1 39,698 457 SCHEDULE END PREP TYPES ALLOWED T of PIPE WALL INTERNAL EIBH cnvncitt <br /> � � � F SIZE THICKNESS DIAMETER nTEBIrrvE IN OuwNs <br /> HYDRAULICCALCULATION DATA 1 40 0.133 1.049 THREADED,CUT GROOVED,ROLL GROOVED,PLAIN END,POLISHED 2.053 0.044 <br /> 6"DI I e °a. ,, 1 1/4 40 0.140 1.380 ROLL GROOVED,POLISHED,PLAIN END(FOR BUTT WELDING) 1.817 0.097 <br /> 15 `% DENSITY: (12) ESFR SPRINKLERS FLOWING AT 40 PSI EACH 11/2 EDDY FLOW 0.086 1.728 ROLL GROOVED,POUSHED,PLAIN END(FOR BUTT WELDING) 2.860 0.122 <br /> 0000 DEMAND AT BASE OF RISER 2 EDDY FLOW 0.086 2.203 ROLL GROOVED,POUSHED,PLAIN END(FOR BUTT WELDING) 3.982 0.198 <br /> °' I $ 1708.9 GPM AT 107.6 PSI ( 0 GPM INSIDE HOSE ALLOWANCE) 21/2 EDDY FLOW 0.085 2.705 ROLL GROOVED,PLAIN END(FOR BUTT WELDING) 5.299 0.298 <br /> s 000o a 6"DI 3 EDDY FLOW 0.063 3.334 ROLL GROOVED,PLAIN END(FOR BUTT WELDING) 7.144 0.453 <br /> � <br /> I= DEMAND AT SOURCE <br /> 10'-9.5" 9'-9.5" 5'-2.5' 4 EDDY FLOW 0.085 4.295 ROLL GROOVED,PLAIN END(FOR BUTT WELDING) 11.290 0.758 <br /> 1959.9 GPM AT 27.5 PSI ( 250 GPM OUTSIDE HOSE ALLOWANCE) <br /> I 5 10 0.134 5.295 ROLL GROOVED,PIAIN END(FOR BUTT WELDING) 17.300 1.144 <br /> 6 *0 0.134 6.357 ROLL GROOVED,PLAIN END(FOR BUTT WELDING) 23.030 1.649 <br /> 8 0.188 8.249 ROLL GROOVED,PLAIN END(FOR BUTT WELDING) 40.080 2.78 <br /> o ** WALL THICKNESS PER NFPA#13 <br /> "I A WET SYSTEM <br /> AREA AREA NUMBER OF <br /> BAKER VIEW: 10`55" = DESCRIPTION SQ.FOOTAGE SPRINKLERS SCOPE OF WORK <br /> OCCUPANCY:S-1,B.F-1 SYS 2 37,288 418 <br /> o CONSTRUCTION TYPE:III-B 1 �O CONc. SMITH FIRE SYSTEMS(SFS)WILL INSTALL(5)WET PIPE SPRINKLER SYSTEMS TO PROTECT THE <br /> I� TOTAL AREA:166,958 FT I • FOOTING HEATED INTERIORS OF THE BUILDING.SFS WILL START WORK AT A 10"SUPPLY FLANGE AND 6" <br /> PARCEL NO:00392200000800 HYDRAULIC CALCULATION DATA FDC FLANGE LOCATED IN THE SPRINKLER ROOM BY OTHERS.THE SYSTEMS WILL BE <br /> r' F.F:ssa'-o" INSTALLED PER NFPA#13 2022 EDITION,NFPA#20 2016 EDITION AND REQUIREMENTS OF THE <br /> Qey, DENSITY: (12) ESFR SPRINKLERS FLOWING AT 40 PSI EACH CITY OF EVERETT. <br /> DEMAND AT BASE OF RISER <br /> 1709.4 GPM AT 100.4 PSI ( 0 GPM INSIDE HOSE ALLOWANCE) CLARIFICATIONS <br /> DEMAND AT SOURCE <br /> 6"DI I - I 15'-0 1959.3 GPM AT 20.3 PSI ( 250 GPM OUTSIDE HOSE ALLOWANCE) 1. THE SPRINKLER RISER ROOM AND ALL AREAS PROTECTED BY WET SYSTEMS MUST BE <br /> MAINTAINED BY OTHERS AT A MINIMUM OF 40'F TO PREVENT FREEZING. <br /> oI 2. STORAGE WILL NOT OCCUR UNDER THE EXTERIOR ENTRY CANOPIES <br /> r I I <br /> WET SYSTEM EXCLUSIONS <br /> AREA AREA NUMBER OF 1. ELECTRICAL WIRING OF ANY KIND. <br /> SFS START POINT DESCRIPTION SQ.FOOTAGE SPRINKLERS 2. CENTRAL STATION ALARM EQUIPMENT,WIRING,AND MONITORING. <br /> Q 6"FDC FLANGE IN <br /> RISER ROOM(BY OTHERS) FIRE PUMP ROOM 3. PAINTING OF SPRINKLER PIPE. <br /> 10" FLG UG1 I SYS 3 13,821 170 4. STRUCTURAL REVIEW. <br /> UG2 6"DI <br /> CI 5. HEAT TRACE AND INSULATION OF SPRINKLER PIPE. <br /> SFS START PAINT • HYDRAULIC CALCULATION DATA 6. DE <br /> RISER ROOM(BY OTHERS) SIGN OR INSTALLATION OFANY UNDERGROUND WORKOFANYKIND(10"WATER <br /> RI 10"SUPPLY FLANGE ° SUPPLY,6"OUT TO YARD FDC). <br /> DENSITY: (12) ESFR SPRINKLERS FLOWING AT 40 PSI EACH 7. HOUSEKEEPING PADS FOR FIRE PUMP AND JOCKEY PUMPS. <br /> ❑ - FIRE PUMP ROOM ,. DEMAND AT BASE OF RISER 8. BEAM PENETRATIONS,ANTICIPATING(276)6-INCH BEAM PENETRATIONS THAT WILL BE <br /> ELEC.ALARM BELL(BY OTHERS) I 1729.2 GPM AT 101.8 PSI ( 0 GPM INSIDE HOSE ALLOWANCE) REQUIRED FOR BRANCHLINES AT GRIDLINES B,C,D,E,&E.5. <br /> _ DEMAND AT SOURCE <br /> 6"DI I <br /> I I FLANGE PLAN 1979.2 GPM AT 22.2 PSI ( 250 GPM OUTSIDE HOSE ALLOWANCE) DESIGN CRITERIA <br /> Z <br /> 0 4 8 <br /> m SCALE 1/4°=1'-o^ PER NFPA 13-2019,SNOHOMISH COUNTY <br /> WET SYSTEM WAREHOUSE-LESS THAN 45'-0"BUIDING HEIGHT <br /> AREA AREA NUMBER OF <br /> (12) K22.4 ESFR SPRINKLERS FLOWING AT 40 PSI MINIMUM. (TABLE 14.4.1) <br /> e I DESCRIPTION SQ.FOOTAGE SPRINKLERS <br /> I 1 I � MAXIMUM BUILDING HEIGHT TO BOTTOM OF ROOF DECKING IS 45'-0" <br /> SYS 4 35,536 396 MAXIMUM STORAGE HEIGHT TO TOP OF STORAGE IS 40'-0" (TABLE 14.4.1) <br /> Io I HYDRAULIC CALCULATION DATA ESFR SPRINKLERS WILL PROTECT THE FOLLOWING: <br /> DENSITY: (12) ESFR SPRINKLERS FLOWING AT 40 PSI EACH 1. CARTONED UNEXPANDED PLASTIC. <br /> s of DEMAND AT BASE 2. CLASS I-IV COMMODITIES,ENCAPSULATED OR UNENCAPSULATED. <br /> 1708.3 AT .0 PSI RISER 3. IDLE WOOD OR PLASTIC PALLETS. <br /> _ WATER SUPPLY INFORMATION DEMAND AM SOURCE <br /> ( 0 GPM INSIDE HOSE ALLOWANCE) 4. OPEN SHELF RACKS <br /> 6"DI I 1958.3 GPM AT 18.9 PSI ( 250 GPM OUTSIDE HOSE ALLOWANCE) <br /> - STATIC 46 PSI <br /> - o - RESIDUAL 21 PSI <br /> •I , <br /> _ FLOWING 2 M SHEET INDEX <br /> I^ = LOCATION OF TEST 1215215 80 BOTH ST.SW-FH SO4 <br /> _ I DATE OF TEST 02.02.23 WET SYSTEM 1 SITE PLAN <br /> DATA SUPPLIED BY CITY OF EVERETT <br /> ELEVATION OF FLOW TEST: 607.31 FTA.S.L. AREA AREA NUMBER OF 2 FIRE PUMP ROOM <br /> 1 DESCRIPTION SQ.FOOTAGE SPRINKLERS <br /> 1 4 I 3 DETAILS <br /> SYS 5 38,773 457 <br /> SITE PLAN SYMBOL 4 AREA1 <br /> - HYDRAULIC CALCULATION DATA 5 AREA <br /> 12"DI EXISTING UNDERGROUND <br /> 1z�DI DENSITY: (12) ESFR SPRINKLERS FLOWING AT 40 PSI EACH 6 AREA 3 <br /> 12"DI DEMAND AT BASE OF RISER <br /> NEW UNDERGROUND(BY OTHERS) 7 AREA 4 <br /> - 11 1715.6 GPM AT 109.2 PSI ( 0 GPM INSIDE HOSE ALLOWANCE) <br /> - T NEW FIRE HYDRANT(BY OTHERS) DEMAND SOURCE 8 AREA 5 <br /> 29.2 PSI ( 250 GPM OUTSIDE HOSE ALLOWANCE)11965 6 GPM AT <br /> V EXISTING HYDRANT <br /> 9 AREA 6 <br /> ►1 NEW VALVE(BY OTHERS) <br /> ❑I D4 EXISTING VALVE <br /> sI �1 0 C{ NEW YARD FDC(BY OTHERS) <br /> z^DI �? ELECTRIC BELL(BY OTHERS) <br /> - a 12 DI <br /> - - - - RC - <br /> UG3 R - <br /> �- BOTH T.SW -- - - PROPERTY LINE <br /> ------------------------ <br /> �� NEW YARD PIV(BY OTHERS) <br /> N <br /> SITE PLAN <br /> 0 25 50 75 100 125 <br /> SCALE 1"=50' <br /> O <br /> 12 <br /> 31/4F <br /> FF <br /> W14x22 W24x55 W14x22 W24x68 W24z62 W24x68 W21x44 I-BEAM W21 x441-BEAM W24x76 60 MIL.TPO SINGLE-PLY W24x551-BEAM <br /> I-BEAM I-BEAM I-BEAM I-BEAM I-BEAM I-BEAM W24x68 I-BEAM ROOFING OVER R-38 RIGID <br /> I-BEAM INSUL.(2 LAYERS <br /> POLYISOCYANURATE <br /> WITH STAGGERED <br /> JOINTS,TYP.)ON METAL <br /> DECK <br /> P.C.PANELS 6.75"CONC.SLAB ON GRADE <br /> 594'-0• <br /> FIFE <br /> SECTION A/1 <br /> FACING SOUTH N.T.S. SITE P LA N <br /> HANGER LEGEND SPRINKLER LEGEND ABBREVIATIONS SYMBOL LEGEND REVISIONS CONTRACT WITH SMITH FIRE SYSTEMS, INC. <br /> SYM MANUFACTURER S.I.N. TYPE MODEL AFF ABOVE FINISHED FLOOR NO. DATE BY REASON FOR REVISION <br /> BOB BOTTOM OF BEAM 12 CENTERLINE OF PIPE TO REFERENCED i■■■■■■■■■■■■■■■■■■■■■■■■■� 1106 54th AVE EAST <br /> BOD BOTTOM OF DECK STRUCTURE IN INCHES SMARTCAP CONSTRUCTION ■ WASH INGTON STATE ■ <br /> BOD CERTIFICATE OF COMPETENCY 5 S TACOMA,WA 98424 <br /> BOP BOTTOM OF PURLI ■ FIRE PROTECTION SPRINKLER SYSTEMS ■ <br /> BOP BOTTOM OF TRLSS ■ ■ CONTR.REG.NO.SMITHFS7360T <br /> lST <br /> SOT BOTTOM OF TRDSS 2-WAY EARTHQUAKE SWAY BRACE 8201 164TH AVE NE,STE 110 <br /> CTS CUT TO SUIT LETTER INDICATES TYPE REDMOND,WA ; Aaron Stewart Nelson Bus: (253)926-1880 FAX: (253)926-2350 <br /> FO FEW ORDER ■ ■ AREA AREA AREA <br /> IFOW INSIDE FACE OF WALL 4-WAY EARTHQUAKE SWAY BRACE 2345-1019-C Level 3 <br /> OFOW OUTSIDE FACE OF WALL LETTER INDICATES TYPE : Smith Fire Systems,Inc. SMARTCAP - BAKER VIEW <br /> NAS NO AUTO.SPRINKLERS ■ d■ AREA 4 AREA 5 AREA 6 <br /> uNo UNLESS NOTED OTHERWISE f HANGER LOCATION PROJECT MANAGER:NOLAN VELLA ■ SMITHFS1360T '•■ <br /> ELEVATION ABOVE REFERENCED PHONE:(206)687-6390 o o: <br /> POINT IN FEET AND INCHES <br /> FAX: ■ Expo-ea■ 1215 BOTH ST SW <br /> O HYDRAULIC CALCULATION NODE SUPERINTENDENT: ■SW nature 2/31 23 EVERETT,WA <br /> FLEXIBLE COUPLING PHONE: �....................... <br /> FAX: DESIGNER PROJECT MGR DATE SHEET JOB NO. <br /> TOTAL THI;SHEET �� RIGID COUPLING CERTIFICATE OF COMPETENCY STAMP KEY PLAN VLAD Y. I B.COOK 1 08.10.23 1 1 OF 9 NC23102 <br />