Laserfiche WebLink
8 <br /> A <br /> T-6.5" 2' 2' 2' 2' V-6.5" 3'-1" 1'-4" 9.5" 1. 9"T7 2'-5" 4'-.5" 1'-8" 2'-2.5" V-5" 2-1" 8'-2.5" <br /> L <br /> EPP <br /> A BLUE <br /> 12 <br /> r 8 <br /> - ELEC.ALARM BELL(BY OTHERS) L (14-10.5) <br /> 1 8 8 8 8 8 <br /> 1(2-0) (2-0) 1 (4-0) �1 <br /> BOR1 N1� OR V OR3 N1� OR4 BOR ` p <br /> - A <br /> L L r <br /> 2 BLUE BLUE BLUE <br /> 4 6 m a 13 13 13 <br /> BLUE (0-11) T <br /> Ir <br /> (1 s) (7-8) (1-0) (0-9) (0-9) (4-9.5)` <br /> BF2 BLUE 11 BLUE 1[4� PIPE _ <br /> STAND <br /> 11 BU ( 6"GRV U TYP. <br /> I� BLUE 1> FLG x GRV e a <br /> I� 5 Y i as ae <br /> 1.25 1.25 T T <br /> 11 (2-3.5) JP (1-5.5) C III III III III III III III III III III III III III <br /> _ = - = _ =III III III -III III -III III- FLOOR DRAIN(BY OTHERS) T�T <br /> _ 2 III III -III III III- III -III III - III D CLEAR SPACE <br /> m m N - - - <br /> wC------------ ----------- ---r------- -- <br /> m ° SECTION B/2 <br /> Vy/ I P <br /> (2)45°ELB <br /> FILLER OWS 2 <br /> BF7 10 BLl <br /> �� 0 2 4 I <br /> BLUE' <br /> E BLUE I5) ` �--ly� SCALE 1/21'-0" a <br /> Y CLEAR SPACE <br /> REQUIRED r P2 1 b 2 "= <br /> FACING NORTH REQUIRED <br /> CLEAR SPACE 1 I�' 8 LL O <br /> � 8 8 <br /> Lb 3 N1 (4-3) (1-0) ® +~°° o-s) n <br /> 4 a <br /> • ° m <br /> � ^ 1 4 I <br /> N 3 BLUE 1> °' 7 8 4 <br /> J B� Y/ v mt 1 N 6„(0-6) BLUE <br /> III ---- --- <br /> a O CLEAR SPACE 8 FLG x GRV 8.5" 1'-4' 3'-2.5" 2'-6.5" 2'-2 5" 4'-11' 10'9 5" <br /> w¢ REQUIRED 8 ° + <br /> O (5-4.5) ni <br /> B <br /> 4 z <br /> 8 <br /> BLUE <br /> BLUE L -'I <br /> p L MIN.5'-0"APART L <br /> 2 ' DRILL 3/32"HOLE IN UNION <br /> e 4 P2 8 8 <br /> - DRAIN & SENSING LINE PLAN <br /> (0-0) 1 (1-3) _ (4-0) 0 2 4 Z <br /> 4 PIPE _ <br /> 4 _ - STAND - SCALE <br /> BLUE ryp, <br /> BLUE <br /> DRAIN PIPING: 1/2"GALVANIZED SCH.-40 ------------- <br /> __ __ ___ __ ___ CONTROLLER PIPING: 1/2"COPPER(TYPE L)PIPE ------------- <br /> PUMP PLAN -III -III --III-III III III III III III III III-III 11-III III III ****SEND STANDARD CONTROLLER AND DRAIN PIPING MATERIALS**** <br /> -1 11--I <br /> 1 1 1 1 I'-1 1 1-1 1 I= 1 1 1 I I I--1 I I-1 1 -I I H I- I -I I-I i - I -I I--1 I--I I - I-- <br /> 1 I--1 I, <br /> 0 2 4 , <br /> SCALE 1/2"=1'-0" <br /> SECTION C/2 <br /> 8 D 2 4 EQUIPMENT LIST <br /> SCALE 1/2"=1'-0' <br /> 1'-6.5" 2' 1 2' 1 2' 1 2' 1 4'-7.5' 1'4" 9.5' 9.5" FACING EAST <br /> �+ ITEM QTY SIZE DESCRIPTION MANUFACTURER MODEL <br /> Y m <br /> 1 O1 y N 1 1 8x6 HOR.SPLIT CASE PUMP P W.DR ROTATION, E,6 GPM 46 1V)PSI) PEERLESS 6AEF16 <br /> �111` _-`F` _-`F` as'-7s" N 2 1 125 HP ELECTRIC FIRE PUMP DRIVER(3 PHASE,60 HZ,460 V) FACTORY CHOICE <br /> oR1 oR oaa oaa oas $36 '-0 3 1 FIRE PUMP CONTROLLER(3 PHASE,60 HZ,460 V,WYE-DELTA OPEN) CUTLERHAMMER FD-70-125D <br /> sv A 4 1 3/4" CASING RELIEF VALVE CALVAL <br /> vRED 3 �7/ ``''� vTAN[>fiGRN E// m v 3 VLW 5-2" 8'-r' 2-s" a'-zs^ <br /> GILD5 1 1.5 HP JOCKEY PUMP(3 PHASE,60 HZ,460 V) GRUNFDOS CR <br /> 3 <br /> 6 1 - JOCKEY PUMP CONTROLLER(3 PHASE,60 HZ,460 V) EATON XTJP <br /> 7 1 1/4" SUCTION PRESSURE GAUGE FACTORY CHOICE <br /> 8 1 1/4" DISCHARGE PRESSURE GAUGE FACTORY CHOICE <br /> � 9 1 1/2" AUTOMATIC AIR RELEASE VALVE CALVAL <br /> GILD[2� RED[> TAN�> GRN > az vLw 10 1 8" OS&Y GATE VALVE GRV X FLG KENNEDY 7092ABF <br /> Y 11 1 8" DOUBLE CHECK BFP W/OS&Y GATE VALVES WILKINS 350A-OSYG <br /> T T 12 (2)(3) (6)(6") SFS STANDARD SHOTGUN RISER: <br /> (2)(3) 1/4" WATER PRESSURE GAUGE ASHCROFT 1005P <br /> 0 11 5 2" TEST&MAIN DRAIN W/PRESSURE RELIEF AGF 1011T <br /> EPDXY COATED 90°ELBOW 6 (2)(3) (8")(6") WATER FLOW SWITCH POTTER ELECTRIC VSR <br /> � (6-9) � <br /> BLUE[1) m �y PIPE � = 13 (1)(2) (6")(8") SWING CHECK VALVE ALEUM DGC <br /> 10x8(0-6)FLG x GRV �m FUG 0 TS`T/PND L:J - 14 (3)(6) (6")(8") BUTTERFLY CONTROL VALVE VICTAULIC 705 <br /> EPDXY COATED ADAPTER BLUE LL 15 2 1.25" OS&Y GATE VALVES UNITED BRASS 18 <br /> o °p 7 16 1 1.25" SWING CHECK VALVE FPPI 99S <br /> _ __ - �I-I i I- I i I-I I i I-I i i I-I -= <br /> �, _ 17 1 8x6 CONCENTRIC REDUCER GRUVLOK 7072 <br /> SLID I> RED[> TAN[> GRN[> `1]YI_w - -I -I III III- III III- III = _I 18 2 12 HEAD SPARE HEAD CABINET RELIABLE A4 <br /> �/ 4 �/ 4 �/ 4� _ iq <br /> Z. <br /> m <br /> SECTION D/2 <br /> m -� F _U F _U F -n <br /> m� D 2 4 <br /> \ m W W W W W SCALE 1/2"=1'-0' <br /> LIE 13 - - FACING NORTH <br /> SPARE SPRINKLERS <br /> 8 8 8 8 8 K THREAD <br /> r MANUFACTURER TYPE MODEL FINISH FACTOR SIZE TEMP QTY <br /> / F ¢ (2 0) ¢ (2-0) ¢ (2-0) ¢ (2 0) OR (4 0) <br /> PIPE STANDTVP. 4 RELIABLE ESFR HL22 BRZ 22.4 1" 165° 20 <br /> NORMALLY OSED BLUE i11�T RELIABLE ESFR HL22 BRZ 22.4 1" 212° 2 <br /> �1 1.25 RELIABLE SSP F1FR BRZ 5.6 1/2" 155° 1 <br /> a AFF <br /> (09) 4 4 4 1.25 RELIABLE SSP F1FR BRZ 5.6 1/2" 212° 1 <br /> ° e 2a.5) SPARE WRENCHES <br /> 111 111 111 111 111 111 111 111 111 1111 111 111 111 111 111 1 -III-III-III-III-III-III-III-III-III-III-III-III-I 1.25 )`@a) (0-3) 1.25 RELIABLE MODEL W2 HEAD WRENCH 1 <br /> . III II -1 I I- <br /> I11 I11'--I 11 1 1 I I I-III I I I (0-3)TxG (0-3)TxG <br /> (4)3/8"KWIK BOLTS RELIABLE MODEL H1 HEAD WRENCH 1 <br /> SECTION A/2 <br /> 0 2 4 JOCKEY PUMP DETAIL <br /> SCALE 1/2"EST FACING EAST FIRE PUMP ROOM <br /> N.T.S. <br /> FACING WEST <br /> HANGER LEGEND SPRINKLER LEGEND ABBREVIATIONS SYMBOL LEGEND REVISIONS CONTRACT WITH SMITH FIRE SYSTEMS, INC. <br /> SYM MANUFACTURER S.I.N. TYPE MODEL AFF ABOVE FINISHED FLoofl NO. DATE BY REASON FOR REVISION <br /> BOB BOTTOM NI BEAM 12 CENTERLINE OF PIPE TO REFERENCED <br /> ■■■■■■■■■ ............... 1106 54th AVE EAST <br /> BOO BOTTOM OF DECK STRUCTURE IN INCHES ■ WASHIE OF C MPET ■ <br /> BOD CERTIFICATE OF COMPETENCY TACOMA,WA 98424 <br /> BOP B0TiOM OF JOIST ■ ■ <br /> BOP BOTTOM OF PUflLIN ■ FIRE PROTECTION SPRINKLER SYSTEMS ■ CONTR.REG.NO.SMITHFS7360T <br /> BOT BOTTOM OF TRUSS LETTER <br /> EARTHQUAKE SWAY BRACE <br /> CrS Cur TO SUIT LETTER INDICATES TYPE Aaron Stewart Nelson Bus: (253)926-1880 FAX: (253)926-2350 <br /> Fo FIELD ORDER <br /> 4-WAY EARTHQUAKE SWAY BRACE ■ 2345-1019-C Level 3 ■ <br /> IFOW INSIDE FACE OF WALL <br /> OFDW NOOUTSIDEUTO.SPE OF WALL LETTER INDICATES TYPE : Smith Fire Systems,Inc. SMARTCAP - BAKER VIEW <br /> NAB NO AUTO.SPRINKLERS PROJECT MANAGER: SMITHFS1360T 0 <br /> UNo UNLESS NOTED OTHERWISE f HANGER LOCATION <br /> A ELEVATION ABOVE REFERENCED PHONE: ■ o■ <br /> POINT IN FEET AND INCHES M <br /> 1215 80TH ST SW <br /> FAX: <br /> O HYDRAULIC CALCULATION NODE SUPERINTENDENT: ■Si nature EVERETT,WA <br /> M FLEXIBLE COUPLING PHONE: �. ................ <br /> FAX: DESIGNER PROJECT MGR I DATE I SHEET JOB NO. <br /> TDTAL THI$$HEET �� RIGID COUPLING CERTIFICATE OF COMPETENCY STAMP KEY PLAN VLAD Y. B.COOK 08.10.23 2 OF 9 NC23102 <br />