My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1606 SE EVERETT MALL WAY ANTHEM SELF STORAGE 2025-07-25
>
Address Records
>
SE EVERETT MALL WAY
>
1606
>
ANTHEM SELF STORAGE
>
1606 SE EVERETT MALL WAY ANTHEM SELF STORAGE 2025-07-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2025 2:44:55 PM
Creation date
7/25/2025 2:42:55 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1606
Tenant Name
ANTHEM SELF STORAGE
Notes
DRAINAGE REPORT AND STORMWATER POLLUTION PREVENTION PLAN (SWPPP)
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> ' DEVELOPED CONDITIONS <br /> The Anthem Self-Storage Facility Project proposes to build a storage building with a <br /> covered drive aisle connecting the proposed storage facility on a 1.75-acre site. The <br /> building will cover approximately 35,750 SF of the site. Approximately 1,000-feet of <br /> paved driveway with a minimum width of 20ft will be constructed for vehicle circulation <br /> around the buildings and access to the storage units. Parking spaces as well as the area <br /> between the proposed building face and edge of drive aisle are also paved. The proposed <br /> ' driveway will take access from Everett Mall Way via a 35-foot wide commercial drop <br /> curb entrance. Parking will be provided near the southwest corner of the site in <br /> conjunction with the office area located near the entrance of the site. <br /> ' A detention system consisting of a concrete vault is proposed to mitigate the increased <br /> storm water runoff from the developed impervious surfaces. Storm water runoff will be <br /> released from the detention vault at rates per the City of Everett and WWHM2012. <br /> The vault was designed and sized using the following parameters: <br /> • The developed contributing basin is the entire development site. All areas not <br /> identified as impervious are assumed to be in lawns and landscaping(see <br /> ' drainage area map in appendix). <br /> • Lawns and landscaped areas shall contain amended soils per 2012 DOE BMP <br /> ' T5.13, and are modeled as "pasture"in WWHM2012. <br /> • Detention calculations are based on an assumption of pre-development second- <br /> growth forested conditions over the entire site. <br /> • Vault: 20ft wide, 160ft long and 9.5ft inside height. <br /> • 9.5ft Riser <br /> • Water Quality detained water levels are lower than filter outlets <br /> I <br /> 1 <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.