V. RUNOFF CONTROL BMP'S <br /> The project requires compliance with the 1997 City of Everett Stormwater Management Manual. <br /> Stormwater will be discharge to the existing 24" storm drain within 4th Avenue West. <br /> A new 24"storm drain will be installed to convey the drainage from the neighboring properties to the <br /> west, replacing the existing 18" storm drain that passes under the proposed building. <br /> Since the development will result in a decrease in impervious area,flow control measures will not be <br /> required. <br /> Water quality measures will be required to treat the 6-mo/24-hr storm event. A Stormfilter manhole <br /> is proposed for water quality treatment. A Stormceptor manhole has been selected as a <br /> pretreatment measure prior to the Stormfilter. <br /> On-site storm drains have been sized to accommodate a 25-year/24-hour storm event using the <br /> Rational Method. <br /> The proposed sediment pond calculations are also included within this section of the report. <br />