> <br /> Everett Housing Authority JN 12080 <br /> May 16, 2012 Page 4 <br /> • <br /> bathing. Excessive water vapor trapped within structures can result in a variety of undesirable <br /> • <br /> conditions, including, but not limited to, moisture problems with flooring systems, excessively moist <br /> air within occupied areas, and the growth of molds, fungi, and other biological organisms that may <br /> be harmful to the health of the occupants. The designer or architect must consider the potential <br /> vapor sources and likely occupant uses, and provide sufficient ventilation, either passive or <br /> mechanical, to prevent a build up of excessive water vapor within the planned structure. <br /> Geotech Consultants, Inc. should be allowed to review the final development plans to verify that the <br /> recommendations presented in this report are adequately addressed in the design. Such a plan <br /> review would be additional work beyond the current scope of work for this study, and it may include <br /> revisions to our recommendations to accommodate site, development, and geotechnical <br /> constraints that become more evident during the review process. <br /> We recommend including this report, in its entirety, in the project contract documents. This report <br /> should also be provided to any future property owners so they will be aware of our findings and <br /> recommendations. <br /> SEISMIC CONSIDERATIONS <br /> In accordance with the International Building Code IBC, the site soil profile within 100 feet of the <br /> ground surface is best represented by Site Class Type D (Stiff Site Class). As noted in the USGS <br /> website, the mapped spectral acceleration value for a 0.2 second (Ss) and 1.0 second period (Si) <br /> equals 1.15g and 0.40g, respectively. <br /> The IBC states that a site-specific seismic study need not be performed provided that the peak <br /> ground acceleration be equal to Sip8/2.5, where Sips is determined in ASCE 7. It is noted that Sips is <br /> equal to 2/3SMs. SMS equals Fa times Ss,where Fa is determined in Table 11.4-1. For our site, Fa = <br /> 1.04. Thus, the calculated peak ground acceleration that we utilized for the seismic-related <br /> parameters of this report equals 0.32g. <br /> The site soils are not susceptible to seismic liquefaction because of their dense nature and/or the <br /> absence of near-surface groundwater. <br /> CONVENTIONAL FOUNDATIONS <br /> As noted earlier, where overexcavation depths are not significant, the proposed structures can be <br /> supported on conventional continuous and spread footings bearing on undisturbed, medium-dense • <br /> native soil, or on structural fill placed above this competent native soil. See the section entitled <br /> General Earthwork and Structural Fill for recommendations regarding the placement and <br /> compaction of structural fill beneath structures. Adequate compaction of structural fill should be <br /> verified with frequent density testing during fill placement. Prior to placing structural fill beneath <br /> foundations, the excavation should be observed by the geotechnical engineer to document that <br /> adequate bearing soils have been exposed. We recommend that continuous and individual spread <br /> footings have minimum widths of 16 and 24 inches, respectively. Exterior footings should also be <br /> bottomed at least 18 inches below the lowest adjacent finish ground surface for protection against <br /> frost and erosion. The local building codes should be reviewed to determine if different footing <br /> widths or embedment depths are required. Footing subgrades must be cleaned of loose or <br /> disturbed soil prior to pouring concrete. Depending upon site and equipment constraints, this may <br /> require removing the disturbed soil by hand. <br /> GEOTECH CONSULTANTS,INC. <br />