My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10632 7TH AVE SE 2025-07-28
>
Address Records
>
7TH AVE SE
>
10632
>
10632 7TH AVE SE 2025-07-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2025 2:54:24 PM
Creation date
7/28/2025 2:48:01 PM
Metadata
Fields
Template:
Address Document
Street Name
7TH AVE SE
Street Number
10632
Notes
FULL DRAINAGE REPORT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
COMPLIANCE WITH APPLICABLE MINIMUM REQUIREMENTS <br /> I <br /> Based on the CITY OF EVERETT STORMWATER MANAGEMENT MANUAL <br /> (February 15, 2010), Volume 1,Figure 2.2 (see attached)this proposed new development project <br /> will comply with Minimum Requirements#1 through#9. The purpose of the requirements is to <br /> prevent and control adverse impacts of the drainage and stormwater on the public health, safety <br /> I and general welfare. To meet these requirements, a Construction Storm Water Pollution <br /> Prevention Plan (SWPPP) has been provided. The following address the 9 Minimum <br /> Requirements: <br /> I <br /> Minimum Requirement#1: STORMWATER SITE PLAN <br /> PREPARATION <br /> A Stormwater Site Plans have been prepared for City of Everett review and approval. These <br /> plans use LID features including infiltration,rain gardens, amended soil and catch basins with oil <br /> water separators'. <br /> 1 <br /> Minimum Requirement#2: CONSTRUCTION STORMWATER <br /> POLLUTION PREVENTION <br /> Plans have been prepared for City of Everett review and approval for both clearing, grading <br /> activities. As shown the plans establish permitted areas for clearing and grading limitations <br /> The twelve elements detailed in volume II, Chapter 2.4 shall be included in the SWPPP and the <br /> construction site operator shall insure that they are implemented unless site conditions render the <br /> element unnecessary and the exemption from that element is clearly justified in the SWPPP. <br /> Minimum Requirement#3: SOURCE CONTROL OF POLLUTION. <br /> The subject area will be graded using BMP's for the proposed 9-residential buildings, 1-veehicle <br /> wash building, private road and sidewalk, 9-driveways, drainage facilities, utilities and the <br /> I mitigation facilities. During grading, equipment will be maintained so as not to be a source of <br /> pollution. Potential pollutant materials for the pole building will not be stored within the parking <br /> area of the site. Any stored materials will be stored within the building site. Construction <br /> equipment and construction vehicle washing will not be allowed. <br /> The building constructed specifically for washing vehicles will drain to the sanitary sewer as <br /> required per city of Everett Stormwater Management Manual (Feb. 15, 2010) Volume IV, Ch. <br /> 3.3, A1.3. <br /> 7 <br />