Laserfiche WebLink
ell <br />"v <br />CLADDING, AS SCHEDULED <br />FURRING, AS SCHEDULED <br />WRB LAP o/ AND SEAL TO VERT. LEG OF FLASHING <br />INSECT SCREEN <br />26 GA. PRE -FINISHED SM'Z' FLASHING w/ FOLDED END DAMS <br />CEMENTITIOUS TRIM/BLOCKING <br />SEAL BETWEEN THE BIB FLANGE AND BLOCKING w/ <br />SILICONE SEALANT <br />HOSE BIB, TYP. <br />SEAL LA <br />(CI <br />HOSE BIB, TYP <br />SCALE:NTS <br />CONTINUOUS CLOSED -CELL SPRAY FOAM (FROM <br />INTERIOR) @ PIPE PENETRATION THROUGH EXTERIOR <br />SHEATHING (AIR SEAL) <br />QUICKFLASH @ ALL PENETRATIONS, TYP. SHINGLE w/ WRB <br />AND TAPE ALL SIDES <br />CLADDING, AS SCHEDULED <br />FURRING, AS SCHEDULED <br />WRB LAP o/ AND SEAL TO QUICKFLASH PANEL, TYP. <br />SEALANT FILLET @ PENETRATION THROUGH SIDING, TYP. <br />PIPE PENETRATION, TYP. <br />CONTINUOUS CLOSED -CELL SPRAY FOAM (FROM <br />INTERIOR) @ PIPE PENETRATION THROUGH EXTERIOR <br />SHEATHING (AIR SEAL) <br />QUICKFLASH PANEL @ ALL PENETRATIONS, TYP. SHINGLE w/ <br />WRB AND TAPE ALL SIDES PER A.B. REQUIREMENTS <br />PIPE PENETRATION, TYP <br />SCALE:NTS <br />PRE -FORMED THROUGH -WALL CORNERS <br />SCALE:NTS <br />tE-FINISHED <br />f DRIP <br />FOLD FLASHING <br />_ . LAP w/ SEALANT <br />(COLOR MATCH) <br />WRB LAP o/ AND SEAL TO VERT. LEG OF FLASHING, <br />TYP. <br />CLADDING, AS SCHEDULED <br />INSECT SCREEN <br />TARGET FLASHING BEHIND VENT FLANGES - EXTEND <br />4" MIN. PAST FLANGES ALL SIDES, TYP. <br />CONTINUOUS CLOSED -CELL SPRAY FOAM (FROM <br />INTERIOR) @DUCT PENETRATION THROUGH EXTERIOR <br />SHEATHING (AIR SEAL) <br />1-PIECE, PRE -MANUFACTURED FLANGED <br />VENT AND HOOD ASSEMBLY <br />a <br />SM VENT FLAP, WHERE APPLICABLE <br />REMOVABLE PERFORATED SCREEN (IF NOT <br />DRYER VENT) <br />SEAL EDGES AND LAPS, TYP. <br />CLADDING, AS SCHEDULED <br />SAM @ INSIDE CORNER, TYP. <br />ALUM. TRIM, AS SCHEDULED <br />FIELD WRB, CONT. @ CORNER <br />FURRING, AS SCHEDULED <br />INSIDE CORNER (o/ R.S.), TYP. <br />SCALE:NTS <br />SEAL EDGES AND <br />LAPS. TYP. <br />FIELD WRB <br />CLADDING, AS <br />SCHEDULED <br />FURRING, AS <br />SCHEDULED <br />NOTE: <br />1. SEAL WRB TO VENT FLANGES AT THE TOP ALUM. TRIM,) <br />TAPE/ SEAL SEAMS AND SIDES. LEAVE BOTTOM FLANGE OPEN SCHEDULI <br />OF WRB, TYP. FOR DRAINAGE. <br />2. VERIFY WITH ARCHITECT VENT ASSEMBLY. <br />3. WRB/TARGET FLASHING SAME FOR VENTS <br />LOCATED IN ENGINEERED STONE VENEER. <br />VENT SHROUD HOOD, TYP. <br />SCALE:NTS <br />CLADDING, AS SCHEDULED <br />FURRING, AS SCHEDULED <br />WRB LAP o/ AND SEAL TO VERT. LEG OF FLASHING, TYP. <br />VENT COVER 1" PROUD OF SIDING, <br />OR, PER ARCH. <br />26 GA. PRE -FINISHED SM 'Z' FLASHING w/ FOLDED END DAMS FACE OF SIDING <br />CEMENTITIOUS TRIM/BLOCKING, TYP. FLAPPER <br />SLOPED TO DRAIN <br />EXTERIOR RATED ELECTRICAL BOX <br />EXTERIOR RATED LIGHT FIXTURE, <br />PER SCHEDULE <br />HEMMED DRIP EDGE <br />�N F1" TYP. @ SIDES, BETWEEN HOLES AND @ <br />BOTTOM. TIGHT TO TOP <br />/Ty <br />S/�FA <br />F <br />R V��TS <br />OUTSIDE CORNER (o/ R.S.), TYP. <br />SCALE:NTS <br />VENTING HOLES, AS REQ'D <br />PROVIDE METAL COLLAR TO <br />RECEIVE VENT SHROUD. <br />SOLDER METAL COLLAR <br />JOINTS AND PROVIDE DRIP <br />EDGE @ BOTTOM <br />M//y <br />LyCONTINUOUS CLOSED -CELL SPRAY FOAM (FROM <br />INTERIOR) @ CONDUIT/WIRE PENETRATION OPENING SIZE - COMBINED <br />THROUGH EXTERIOR SHEATHING (AIR SEAL) SOFT FROM VENT DUCTS <br />24 GA. (MIN.) PRE -FINISHED SM VENT <br />QUICKFLASH PANEL - FLANGED TO SHAPE SH ROUD. COLOR TO MATCH ADJACENT <br />OF ELECTRICAL BOX SIDING FROM MANUF. STANDARD COLORS <br />(PER ARCH.) <br />NOTE: <br />WRB CONT. FROM BELOW 1. MECHANICAL PANEL SCREEN PER ELEVATIONS (PER <br />ARCH.). NFVA TO MEET CODE, COLOR TO MATCH Z <br />ADJACENT CLADDING (OR, PER ARCH). <br />EXT. LIGHT FIXTURE, TYP. <br />SCALE:NTS <br />VENT SHROUD, TYP. <br />SCALE:NTS <br />WRB, LAP o/ AND SEAL TO <br />VERT. LEG OF FLASHING, TYP. <br />CLADDING, AS SCHEDULED <br />SEAL WRB TO VERT. LEG OF <br />FLASHING, TYP. <br />24 GA. PRE -FINISHED SM FLASHING w/ 2y" <br />DRIP (MATCH ADJACENT DECK EDGE <br />FLASHING, WHERE APPLICABLE). BED <br />FLASHING IN SEALANT. TYP. <br />EXTEND WRB CONT. BEHIND <br />BELLY BAND TRIM, TYP <br />TRIM, AS SCHEDULED <br />CLADDING, AS SCHEDULED <br />THROUGH -WALL FLASHING @ BELLY BAND, TYP. <br />SCALE:NTS <br />17. <br />SEAL EDGE, <br />INSIDE CORNER, TYP. <br />SCALE:NTS <br />FIELD WRB <br />CLADDING, AS <br />SCHEDULED <br />SAM @ OUTSIDE <br />CORNER. TYP <br />Tf <br />OUTSIDE CORNER, TYP. <br />SCALE:NTS <br />CLADDING, AS SCHEDULED <br />FURRING. AS SCHEDULED <br />WRB, LAP o/ AND SEAL TO VERT. LEG OF <br />FLASHING, TYP. <br />INSECT SCREEN <br />24 GA. PRE -FINISHED SM FLASHING w/ 2y" <br />DRIP. ALLOW FOR BUILDING MOVEMENT - <br />VERIFY w/ STRUCTURAL <br />FIELD WRB CONT. BEHIND <br />FLASHING, TYP. <br />THROUGH WALL FLASHING, TYP <br />SCALE:NTS <br />V) <br />01. <br />M <br />O <br />N <br />ui <br />0') <br />LN <br />Z <br />z <br />� O <br />0 <br />z <br />C) z <br />U) <br />Z <br />Q <br />W <br />I..L <br />JU <br />Lu <br />0 <br />D- D- <br />LLl LLl <br />LLl LLl <br />• • v <br />0 <br />• • • N <br />r <br />0 <br />cl) <br />m � <br />44�d <br />E <br />0 <br />o <br />�m <br />c r <br />m CID <br />o r m <br />O 0 <br />> m <br />(h M > <br />Q <br />a <br />m <br />-3 <br />LOIw <br />m <br />m 00 0 <br />m <br />N N <br />3 <br />— <br />co <o 3 <br />0 <br />O N <br />0 <br />00 3 <br />N N <br />N m <br />N W <br />3 <br />EXTERIOR <br />DETAILS <br />2020-1009 PERMIT SET <br />THE UNDERSIGNED HAS <br />PROVIDED <br />BUILDING ENCLOSURE DOCUMENTS <br />THAT, IN MY PROFESSIONAL <br />JUDGEMENT, ARE APPROPRIATE TO <br />SATISFY THE REQUIREMENTS OF RCW <br />64.55.005 THROUGH 64.55.090. <br />COPYRIGHT© 2019 OAC SERVICES, INC. <br />THESE DOCUMENTS, THE IDEAS AND DESIGNS INCORPORATED <br />HEREIN AS AN INSTRUMENT OF SERVICE, ARE THE PROPERTY OF <br />OAC SERVICES, INC. AND ARE NOT TO BE USED IN WHOLE OR IN <br />PART WITHOUT WRITTEN AUTHORIZATION OF OAC SERVICES, INC <br />DESIGN <br />KRM <br />DRAWN <br />KRM <br />CHECK <br />XBE5,05 <br />CAC PROJ. No. <br />