Laserfiche WebLink
NOT USED <br />RAILING ATTACHMENT <br />SCALE:NTS \ ' / SCALE:NTS <br />NOT USED r 4 \ NOT USED <br />SCALE:NTS \ " / SCALE:NTS <br />NOT USED r \ NOT USED <br />SCALE:NTS <br />SCALE:NTS <br />�'^'"'^ AS SCHEDULED <br />DNTINUOUS <br />SIDING. AS SCHEDULED <br />C� <br />RGET FLASHING BEHIND BLOCKING <br />EXTEND <br />FITIOUS BLOCKING MEMBRANE CONT. <br />4" ONTO FACE OF <br />SHEATHING, TYP. <br />AND ATTACHMENT. PER ARCH. <br />CORNER TRIM, <br />EXTENDED BELOW <br />WR <br />SHING <br />CORNER TRIM, AS <br />SCHEDULED <br />DECK TO WALL INTERFACE <br />SCALE:NTS <br />5 DECK TO OUTSIDE WALL (FLUS <br />SCALE:NTS <br />EXTERIOR SHT'G <br />WRB (NOT SHOWN) TO <br />SHINGLE OVER VERTICAL <br />FLANGE AND SEAL <br />24 GA. GALVANIZED SM <br />BOOT FLASHING <br />DECK EDGE FLASHING, PER <br />TYPICAL DETAIL 5/XBE4.04 <br />FASCIA, TO BE FIT FLUSH <br />w/ ADJACENT SIDING. <br />CONTRACTOR TO VERIFY <br />WIDTH OF FASCIA <br />DECK TO WALL (PERPENDICU <br />SCALE:NTS <br />UPTURN MEMBRANE 6" <br />MIN. TO WALL <br />SHEATHING <br />24 GA. SM DECK TO <br />WALL FLASHING <br />DECK MEMBRANE, <br />AS SCHEDULED <br />DECK EDGE FLASHING - <br />REF. DETAIL 2/XBE5.04, TYP. <br />EXTERIOR SHT'G <br />24 GA. GALVANIZED SM <br />BOOT FLASHING <br />col <br />DECK EDGE FLASHING, PER <br />TYPICAL DETAIL 5/XBE4.01 <br />FASCIA, TO BE FIT FLUSH w/ <br />ADJACENT SIDING. <br />CONTRACTOR TO VERIFY <br />WIDTH OF FASCIA <br />�� <br />IJ <br />WRB, LAP o/ MEMBRANE AND SEAL <br />BOTTOM EDGE, TYP. <br />CLADDING, AS SCHEDULED <br />24 GA. PRIMED SM FLASHING (OR MESH), <br />N TYP., PER MEMBRANE MANUF. <br />REQUIREMENTS <br />DECK WP MEMBRANE - CONTINUOUS <br />UP JAMBS 6" MIN. MEMBRANE TO <br />ADHERE DIRECT TO SHEATHING, TYP. <br />SLOPE 2% MIN. <br />DECK FRAMING, AS SCHEDULED <br />WRB TARGET - CONTINUOUS BEHIND <br />DECK LEDGER, TYP. - PROVIDE A 6" <br />MIN. LAP EA. SIDE OF LEDGER <br />DECK TO WALL, TYP <br />SCALE:NTS <br />ALUM. GUARDRAIL - FACE <br />MOUNT TO <br />MOISTURE -RESISTANT <br />BLOCKING, TYP. <br />24 GA. GALV. SADDLE <br />FLASHING - SEE DETAIL <br />5,6/XBE5.04, TYP. <br />ROUTE EDGE OF SHEATHING <br />TO ALLOW FOR FLUSH <br />INSTALL OF FLASHING. TYP. <br />24 GA. PRIMED SM <br />FLASHING w/ HEMMED <br />DRIP <br />FASCIA, PER ARCH. <br />DECK EDGE FLASHING, TYP. <br />SCALE:NTS <br />rRA!"I <br />NOTE: <br />1. SIMILAR AT CONCRETE PODIUM. <br />DECK EDGE FLASHING W/ OVERFRAMING, TYP <br />SCALE:NTS <br />)RAIL -TOP MOUNT, PER <br />RILL FASTENER HOLES/ <br />NE SEALANT PRIOR TO <br />3TALLATION <br />V) <br />M <br />O <br />N <br />ui <br />0') <br />LN <br />Z <br />z <br />� O <br />0 V <br />06 <br />z <br />z <br />C) <br />Lu <br />J <br />U' Lu <br />0 <br />(If <br />LLJ LLJ <br />W W <br />• • • <br />0 <br />• • • N <br />r <br />0 <br />cl) <br />m � <br />E <br />0 <br />o <br />�m <br />c r <br />0) CID <br />o r m <br />Or 0 <br />> m <br />(h M > <br />Q <br />a <br />N <br />3� <br />n m <br />0 co 0 <br />a) <br />N N <br />. . 3 <br />U- — <br />co <o 3 <br />0 <br />O N <br />0 <br />00 3 <br />N N <br />N a) <br />N W <br />3 <br />EXTERIOR <br />DETAILS <br />2020-1009 PERMIT SET <br />THE UNDERSIGNED HAS <br />PROVIDED <br />BUILDING ENCLOSURE DOCUMENTS <br />THAT, IN MY PROFESSIONAL <br />JUDGEMENT, ARE APPROPRIATE TO <br />SATISFY THE REQUIREMENTS OF RCW <br />64.55.005 THROUGH 64.55.090. <br />ROUTE EDGE OF SHEAI <br />TO ALLOW FOR FLUSH <br />INSTALL OF FLASHING,' <br />24 GA. PRE -FINISHED <br />SM FLASHING w/ <br />HEMMED DRIP <br />CLADDING, AS <br />SCHEDULED <br />OVER -FRAMING, PER <br />ARCH. <br />131112 RIIIISTEGIEARAHTEcEr <br />COPYRIGHT© 2019 OAC SERVICES, INC. <br />THESE DOCUMENTS, THE IDEAS AND DESIGNS INCORPORATED <br />HEREIN AS AN INSTRUMENT OF SERVICE, ARE THE PROPERTY OF <br />OAC SERVICES, INC. AND ARE NOT TO BE USED IN WHOLE OR IN <br />PART WITHOUT WRITTEN AUTHORIZATION OF OAC SERVICES, INC <br />DESIGN <br />KRM <br />DRAWN <br />KRM <br />CHECK <br />XBE5,04 <br />CAC PROJ. No. <br />