Laserfiche WebLink
SECTION 01 40 00 QUALITY ASSURANCE <br />AIR BARRIER REQUIREMENTS <br />PER THE 2015 WSEC, SECTION C402.5.1 AIR BARRIERS, "A CONTINUOUS AIR BARRIER SHALL BE PROVIDED THROUGHOUT THE BUILDING THERMAL ENVELOPE. THE AIR BARRIER SHALL BE PERMITTED ON THE INSIDE OR OUTSIDE OF THE BUILDING ENVELOPE, LOCATED WITHIN THE ASSEMBLIES COMPOSING THE ENVELOPE, OR ANY COMBINATION THEREOF. THE AIR BARRIER SHALL <br />COMPLY WITH SECTION C402.5.1.1 AND C402.5.1.2." 1.4. PER OWNER, ESDS V3.0 SECTION 5.1A, ADDITIONAL CREDIT TO BE ACHIEVED BY SELECTING ITEM #8 FROM WSEC C406.9 REDUCED AIR INFILTRATION THE MEASURED AIR LEAKAGE RATE OF THE BUILDING ENVELOPE SHALL NOT EXCEED 0.25 CFM/FT2 AT A PRESSURE DIFFERENTIAL OF 0.3 INCHES WATER GAUGE (2.0 US X M2 AT <br />75 Pa). REFER TO SHEET XBE0.01, SECTION A.5 FOR OWNER REQUIREMENTS TO MEET ADVANCED AIR INFILTRATION, PER 2015 WSEC C406.9. <br />AIR BARRIER PRE -CONSTRUCTION MEETING <br />HOLD BUILDING ENVELOPE PRE -CONSTRUCTION MEET AT CONSTRUCTION COMMENCEMENT. DISTRIBUTE CONTACT INFORMATION AND REVIEW ROLES AND RESPONSIBILITIES IN REGARDS TO THE ARCHITECT, BUILDING ENCLOSURE CONSULTANT, GENERAL CONTRACTOR, TESTING AGENCY, AND ANY APPLICABLE TRADES. DISCUSS OBSERVATION SCHEDULE, FIELD REPORTING, <br />SUBMITTALS, SUBSTITUTION REQUESTS, FIELD TESTING, CONSTRUCTION SEQUENCING, AND GENERAL REQUIREMENTS. <br />PRE -INSTALLATION MEETING <br />HOLD INDIVIDUAL PRE -INSTALLATION MEETINGS, AS NECESSARY, PRIOR TO THE START OF WORK OF EACH ENCLOSURE -RELATED TRADE WORK (I.E. INSULATION, ROOFING, WEATHER BARRIERS, WINDOW INSTALLATION, SIDING, ETC.) TO ENSURE PROPER COORDINATION AND INSTALLATION OF THE BUILDING ENVELOPE SYSTEMS. REPRESENTATIVE OF ALL INVOLVED PARTIES <br />SHOULD BE PRESENT INCLUDING OWNER, GENERAL CONTRACTOR, SUBCONTRACTOR, ARCHITECT, BUILDING ENCLOSURE CONSULTANT, AND SPECIFIC PRODUCT MANUFACTURER REPRESENTATIVES. APPLICABLE SUBMITTAL ITEMS SHOULD BE REVIEWED AND APPROVED PRIOR TO PRE -INSTALLATION MEETINGS. <br />TRADE CONTRACTOR'S ARE ENCOURAGED TO PROVIDE VALUE ENGINEERING SUGGESTIONS AND MAYSUBMIT ALTERNATE PRODUCTS FOR REVIEW AND APPROVAL BY OWNER/CONTRACTOR AND ARCHITECT/BUILDING ENVELOPE CONSULTANT. ALLOWADDITIONAL TIME FOR REVIEWAND APPROVALS. <br />MOCK-UPS <br />EACH TRADE CONTRACTOR SHALL COMPLETE A MOCK-UP OF THEIR WORK TO DETAIL THE CORRECT MATERIALS, METHODS, SEQUENCING, AND INTERFACING OF THEIR WORK WITH OTHER TRADES FOR REVIEW AND APPROVAL BY OWNER/CONTRACTOR AND BUILDING ENVELOPE CONSULTANT. THE MOCK-UP WILL SERVE AS THE APPROVED METHOD OF INSTALLATION AND THE <br />MODEL FOR ALL WORK IN PLACE ON THE PROJECT. THE MOCK-UP WILL BE FREESTANDING, OR COMPLETED AS AN INTEGRAL PART OF FINAL WORK IN PLACE AT THE DISCRETION OF THE OWNER. <br />PRODUCT RECOMMENDATIONS <br />SPECIFICATION NUMBER <br />PRODUCT <br />APPLICATION <br />COMMENTS <br />PRIMARY <br />ALTERNATE(S) <br />TREMCO: TREMGARD HB <br />03 30 00 <br />PENETRATING SEALER (CLEAR) <br />WATER REPELLANT FOR EXPOSED C.I.P. WALLS ENCOMPASSING <br />BASF: MASTERPROTECT H1000 <br />TNEMEC: DU A PELL 100 <br />CAST IN PLACE CONCRETE <br />CONDITIONED SPACES <br />W.R. MEADOWS: PENTREAT 244-100 <br />WATERPROOF COATING AT EXPOSED CMU WALLS <br />ENCOMPASSING CONDITIONED SPACES, EQUIPMENT ROOMS, <br />TNEMEC: ENVIRO-CRETE 156 <br />ELASTOMERIC WATERPROOFING <br />OR STORAGE ROOMS (RECOMMENDED OVER WATER <br />BASF: MASTERPROTECT EL 750 <br />DOWSIL: ALLGUARD <br />REPELLANT) <br />TREMCO: TREMGARD HB <br />04 43 13 <br />PENETRATING SEALER (CLEAR) <br />WATER REPELLANT FOR EXPOSED STONE VENEERS <br />BASF: MASTERPROTECT H1000 <br />TNEMEC: DU A PELL 100 <br />ADHERED STONE MASONRY <br />ENCOMPASSING CONDITIONED SPACES <br />W.R. MEADOWS: PENTREAT 244-100 <br />WATER REPELLANT & ANTI -GRAFFITI COATING <br />WATER REPELLANT AND ANTI -GRAFFITI COATING FOR STONE <br />(CLEAR) <br />VENEERS ENCOMPASSING CONDITIONED SPACES <br />PROSOCO: BLOK-GARD & GRAFFITI CONTROL II <br />TNEMEC: DU A PELL 100 <br />07 11 13 <br />COLD -APPLIED EMULSIFIED -ASPHALT <br />EXTERIOR WALLS IN CONTACT WITH EARTHWORKOR OTHER <br />W.R. MEADOWS: SEALMASTIC EMULSION <br />CANNOT BE USED IN LIEU OF A WATERPROOFING MEMBRANE - DO NOT USE WHEN ADJACENT TO <br />BITUMINOUS DAMP PROOFING <br />MEMBRANE <br />BACKFILL (NON -WATERPROOFING) <br />BASF: MASTERSEAL 610 <br />KARNAK: 83 FIBERED DAMP PROOFING <br />CONDITIONED SPACE. <br />07 14 20 <br />FOUNDATION WATERPROOFING, OR BELOW TOPPING SLABS <br />HOT- OR COLD -FLUID APPLIED <br />COLD, SHEET MEMBRANE SYSTEM <br />AND PAVERS. INSTALL WITH PROTECTION BOARD (OR DRAIN <br />CARLISLE: MIRADRI 860-ULT <br />GCP APPLIED TECHNOLOGIES: BITUTHENE 3000 <br />WATERPROOFING <br />MAT) OVER MEMBRANE <br />GCP APPLIED TECHNOLOGIES: PREPRUFE 30OR <br />DRAINAGE PLANE COLLECTOR AND CONNECTION TO PIPED <br />VERIFY APPLICABLE DRAIN MAT FOR THE CONDITIONS BEING INSTALLED (I.E. COMPRESSIVE <br />GEO-COMPOSITE DRAINAGE MAT <br />DRAINAGE SYSTEM <br />CARLISLE: MIRADRAIN <br />GCP APPLIED TECHNOLOGIES: HYDRODUCT <br />STRENGTH, DRAINAGE CAPABILITIES, ETC.). <br />07 18 13 <br />WATERPROOFING MEMBRANE FOR PEDESTRIAN TRAFFIC <br />PEDESTRIAN TRAFFIC <br />HORIZONTAL WATERPROOFING SYSTEM <br />VERSAFLEX: FSS 45DC-F <br />SURFACES <br />COATINGS <br />07 26 00 <br />VAPOR RETARDER <br />PRINTABLE VAPOR RETARDER AND AIR BARRIER PAINT (PVA) <br />BENJAMIN MOORE: ULTRA SPEC LATEX VAPOR <br />SHERWIN WILLIAMS: PVA INTERIOR LATEX PRIMER & <br />VERIFY PRODUCTS ARE COMPLIANT WITH ESDS REQUIREMENTS. <br />VAPOR RETARDERS <br />BARRIER PRIMER SEALER 573 <br />SEALER <br />UNDER CONCRETE SLAB -ON -GRADE CONDITIONS <br />VAPOR RETARDER <br />STEGO INDUSTRIES: STEGO WRAP 15-MIL <br />VIPER II: VAPORCHECK 15-MIL <br />INSTALL PER MANUFACTURERS RECOMMENDED INSTALLATION INSTRUCTIONS AND ACCESSORIES. <br />ENCOMPASSING CONDITIONED SPACES <br />MECHANICALLY ATTACHED SHEET MEMBRANE BEHIND SIDING <br />VAPROSHIELD: WRAPSHIELD IT <br />072500 <br />WEATHER -RESISTIVE BARRIER SHEET <br />AT CMU/FRAMED WALLS. APPROVED FOR AIR BARRIER <br />DUPONT: TYVEK DRAINWRAP <br />DORKEN: DELTA -VENT S <br />INSTALL PER MANUFACTURERS RECOMMENDED INSTALLATION INSTRUCTIONS. <br />WEATHER BARRIERS <br />MEMBRANE <br />APPLICATIONS (NON -EXPOSED CLADDING ASSEMBLIES) <br />KINGSPAN: GREENGUARD C2000 <br />TROWL, ROLL, OR SPRAY -APPLIED MEMBRANE BEHIND SIDING <br />TREMCO: EXOAIR 230 <br />WEATHER -RESISTIVE BARRIER FLUID -APPLIED <br />AT CMU/FRAMED WALLS. APPROVED FOR AIR BARRIER <br />PROSOCO: R-GUARD SYSTEM <br />GCP APPLIED TECHNOLOGIES: VPL50 <br />MEMBRANE <br />APPLICATIONS (NON -EXPOSED CLADDING ASSEMBLIES) <br />DUPONT: FLUID APPLIED WBER <br />ACCESSORY MATERIALS: ROUGH OPENING <br />SHEET MEMBRANE FOR WINDOWS AND DOORS PENETRATION <br />DUPONT: TYVEK DRAINWRAP <br />VAPROSHIELD: WRAPSHIELD IT/SA <br />FLASHING <br />FLASHING <br />DUPONT: TYVEKCOMMERCIAL WRAP <br />ACCESSORY MATERIALS: ROUGH OPENING <br />FLUID -APPLIED MEMBRANE FOR WINDOWS AND DOORS <br />PROSOCO: FAST FLASH <br />VAPROSHIELD: VAPROLIQUI-FLASH <br />FLASHING <br />PENETRATION FLASHING <br />VAPROSHIELD:VAPROTAPE <br />DORKEN: DELTA -MULTI BAND <br />ACCESSORY MATERIALS: ROUGH OPENING <br />ADHESIVE MEMBRANE AND SILL FLASHING COMPONENTS OF <br />DUPONT: FLASHING TAPE <br />DORKEN: DELTA -FLASHING <br />FLASHING <br />PENETRATION FLASHING SYSTEM <br />DUPONT: FLEXWRAP NF <br />DORKEN: DELTA-FLEXX-BAND <br />SIGA: WIGLUV ## (TAPE) <br />NICHIGO: G-TAPE <br />ACCESSORY MATERIALS: COMPOSITE FLASHING <br />FLASHING PANELS AT STANDARD PENETRATIONS (ELECT. <br />PANELS <br />BOXES, VENTS, PIPES, HOSE BIBS, ETC.) <br />WEATHERPROOFING PRODUCTS: QUICKFLASH <br />ACCESSORY MATERIALS: SELF-ADHESIVE <br />SELF -ADHERED MEMBRANE AT BUILDING TRANSITIONS AND <br />PROTECTOWRAP: PS 45 <br />MEMBRANE ("SAM") <br />UNIQUE CONDITIONS THAT MAY NOT BE COVERED BY PRIMARY <br />GCP APPLIED TECHNOLOGIES: VYCOR <br />DUPONT: FLASHING TAPE <br />VERIFY SUBSTRATE/WRB/ROOFING COMPATIBILITIES PRIOR TO INSTALLING. <br />WRB SYSTEM <br />H&B: TEXTROFLASH <br />ACCESSORY MATERIALS: HIGH -TEMPERATURE <br />SELF -ADHERED MEMBRANE BELOW SHEET METAL CONDITIONS <br />GCP APPLIED TECHNOLOGIES: ULTRA <br />TREMCO: EXOAIR 111 <br />SELF-ADHESIVE MEMBRANE ("HTSAM") <br />SUBJECTED TO HIGHER TEMPERATURES <br />GCPAPPLIED TECHNOLOGIES: ICE & WATER SHIELD <br />CARLISLE: CCW WIP300 <br />VERIFY SUBSTRATE/WRB/ROOFING COMPATIBILITIES PRIOR TO INSTALLING. <br />PROTECTOWRAP: JIFFY SEAL HT <br />0731 13 <br />CERTAINTEED: LANDMARK <br />ASPHALT SHINGLE ROOFING PANELS <br />STEEP -SLOPE ROOFING <br />GAF: TIMBERLINE HD <br />ASPHALT SHINGLES <br />MALARKEY: LEGACY <br />07 54 19 <br />CARLISLE: SURE -FLEX PVC <br />POLYVINYL -CHLORIDE (PVC) <br />SINGLE -PLY SHEET MEMBRANE ROOFING <br />LOW -SLOPE ROOFING - 60-MIL MINIMUM <br />GAF: EVERGUARD PVC <br />SIKA: SARNAFIL PVC <br />ROOFING <br />07 54 23 <br />CARLISLE: SURE -WELD TPO <br />THERMOPLASTIC (TPO) <br />SINGLE -PLY SHEET MEMBRANE ROOFING <br />LOW -SLOPE ROOFING - 60-MIL MINIMUM <br />GAF: EVERGUARD EXTREME TPO <br />JOHNS MANVILLE: JM TPO <br />ROOFING <br />V) <br />co <br />O <br />N <br />ui <br />0') <br />LID <br />Z <br />z fn <br />COO <br />0 V <br />Z <br />U) <br />Z <br />Q <br />W <br />J <br />U' W <br />0 <br />�(If <br />W W <br />W W <br />• • v <br />0 <br />• • • N <br />r <br />0 <br />cn <br />m � <br />E <br />0 <br />o <br />� m <br />c r <br />NaD <br />o r y <br />Or U <br />> M <br />m M > <br />Q <br />a <br />- N <br />-3 <br />L0Iw <br />co 00 0 <br />a� <br />N N <br />3 <br />ILL — <br />co co 3 <br />O <br />0 N <br />00 3 <br />N N <br />N0 N <br />N cn <br />3 <br />PRODUCT <br />MATRIX <br />2020-1009 PERMIT SET <br />THE UNDERSIGNED HAS <br />PROVIDED <br />BUILDING ENCLOSURE DOCUMENTS <br />THAT, IN MY PROFESSIONAL <br />JUDGEMENT, ARE APPROPRIATE TO <br />SATISFY THE REQUIREMENTS OF RCW <br />64.55.005 THROUGH 64.55.090. <br />a Mon T000mmmco—Ill <br />COPYRIGHT© 2019 OAC SERVICES, INC. <br />THESE DOCUMENTS, THE IDEAS AND DESIGNS INCORPORATED <br />HEREIN AS AN INSTRUMENT OF SERVICE, ARE THE PROPERTY OF <br />OAC SERVICES, INC. AND ARE NOT TO BE USED IN WHOLE OR IN <br />PART WITHOUT WRITTEN AUTHORIZATION OF OAC SERVICES, INC <br />DESIGN <br />KRM <br />DRAWN <br />KRM <br />CHECK <br />XBEO,02 <br />OAC PROJ. No. <br />R12-2o0��70� <br />