My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8102 EVERGREEN WAY EVERETT 4 CORNERS - BLDG B 2025-08-22
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG B
>
8102 EVERGREEN WAY EVERETT 4 CORNERS - BLDG B 2025-08-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2025 11:16:45 AM
Creation date
7/29/2025 6:29:44 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG B
Imported From Microfiche
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1616
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'VIEW OF WINDOW I <br />FROM INTERIOR <br />MIN. SEALANT JOINT w/ BACKER ROD <br />AROUND INTERIOR PERIMETER OF <br />WINDOWAT HEAD, JAMBS, AND SILL TO <br />MEET AIR AND WATER INFILTRATION <br />REQUIREMENTS. SIM. @ SLIDING GLASS <br />DOORS <br />@ SILL, INSTAL <br />BACKER ROD BET <br />1 LIYL I lx( I1V11 Vvlx( l <br />STEP J: INTERIOR SEALANT JOINT <br />SCALE:NTS <br />GENERAL NOTES: <br />1. WINDOW WRAP SEQUENCE CONFORMS AND IS APPROVED BY TYVEK AND <br />SHOULD NOT BE DEVIATED FROM FOR THIS PROJECT WITHOUT PRIOR <br />APPROVAL. TYVEK APPROVAL VIA EMAIL TO OAC/HEARTLAND 2018-08-05. <br />2. REFER TO MANUFACTURER'S INSTRUCTIONS AND INSTALLATION <br />GUIDELINES FOR ADDITIONAL INFORMATION. <br />3. REFER TO SHEET XBE1.00 AND NOTES ON PAGE XBE7.00 FOR ADDITIONAL <br />AIR BARRIER INFORMATION. <br />4. ALL SEAMS IN WRB/ PENETRATION WRAP ARE TO BE SEALED OR TAPED, <br />IN ACCORDANCE WITH THE AIR BARRIER INSTALLATION REQUIREMENTS, <br />PER THE 2015 WASHINGTON STATE ENERGY CODE (WSEC) TABLE <br />C402.5.1.1 AND R402.4.1.1. <br />6", TY <br />INSTALL FIELD WRB IN A SHINGLED, <br />WATER -SHEDDING MANNER. TAPE/ <br />SEAL ALL SEAMS PER AIR <br />REQUIREMENTS <br />6". TY <br />STEP G: FIELD WRB <br />SCALE:NTS <br />INSTALL 24 GA. PRE -FINISHED SM <br />FLASHING w/ FOLDED END DAMS <br />AND HEMMED DRIP. REFER TO <br />DETAIL 1/XBE2.01 FOR TYPICAL <br />WINDOW HEAD FLASHING <br />LOCATION(S) AND INTEGRATION <br />TRIM, AS SCHEDULED. ALLOW FOR <br />Ay" SEALANT JOINT BETWEEN <br />WINDOW FRAME AND TRIM, ALL <br />SIDES. <br />STEP H: TRIM & SHEET METAL HEAD FLASHING <br />SCALE:NTS <br />WRB, LAPPED o/ HEAD FLASHING <br />AND SEALED TO THE VERTICAL <br />LEG, TYP. <br />TAPE/ SEAL SEAMS, TYP. <br />FIELD WRB FROM ABOVE <br />SCALE:NTS <br />CUT AND FOLD PENETRATION FLASHING <br />INTO ROUGH OPENING @ HEAD, MIN. 4" <br />PENETRATION FLASHING TO BE OF WRB, <br />TYP. <br />TAPE BOTTOM EDGE OF JAMB <br />FLASHING, PER AIR REQUIREMENTS <br />E✓]IW11►1 <br />9", TYP. <br />3", OR TO DEPTH OF WINDOW FR Y2" <br />STEP D: HEAD PENETRATION FLASHING <br />SCALE:NTS <br />PROVIDE COMPLETE SEAL (CONTINUOUS <br />SEALANT) BETWEEN PENETRATION <br />FLASHING AND WINDOW JAMB AND HEAD <br />FLANGES. SEALANT SHOULD FLOW OUT <br />BEYOND EDGE OF WINDOW FLANGES AND <br />FILL FLANGE NAIL HOLES, TYP. <br />INSTALL WINDOW PER <br />MANUFACTURER'S SPECIFICATIONS, IF <br />OAC WINDOW INSTALLATION DIFFERS <br />FROM MANUF. INSTALLATION <br />INSTRUCTIONS, NOTIFY OAC OF <br />DISCREPANCIES <br />INSTALLY16 SHIMS <br />SILL FLANGE TO PR( <br />PATH FOR DRAINX <br />STEP E: SET FLANGED WINDOW <br />SCALE:NTS <br />V. <br />4" BUTYL FLASHING TAPE o/ <br />JAMBS AND HEAD - EXTEND TAPE <br />@ HEAD 1" PAST JAMB TAPE EA. <br />SIDE, TYP. <br />FIELD WRB FROM BELOW- TUCK <br />UNDER SILL BIB, TYP. TAPE/ SEAL <br />SEAMS, PER AIR REQUIREMENTS <br />CUT PENETRATION FLASHING AND <br />FOLD THROUGH ROUGH OPENING, <br />MINIMUM 4". SILL FLASHING TO BE <br />NON -ADHESIVE SHEET MEMBRANE, <br />OR APPROVED EQUAL <br />9" MIN. <br />CyY <br />E]Y <br />9119� +Y <br />OR TO DEPTH OF WINDOW" <br />1 <br />STEP A: SILL PENETRATION FLASHING <br />SCALE:NTS <br />FLEXWRAP NF CORNER "BOOT". INSTALL <br />THE JAMB AND SILL FACES FIRST AND <br />PULL SAM OVER THE CORNER TO THE <br />VERTICAL FACE OF THE SHT'G, TYP. <br />CREATE CONTINUOUS <br />CORNER BOOT. TYP. <br />STRAIGHTFLASH CONTINUOUSL <br />OVER SILL (6") - TO BE INSTALLED P <br />"SILL PAf. <br />,a V1111V1V JNDER WINDOW TO PROVIDE CLEAR <br />DRAINAGE AND ALLOW FOR CONTINUOUS SILL <br />SEALANT JOINT. VERIFY WITH MANUFACTURER <br />SHIM REQUIREMENTS. ADDITIONAL SHIMS MAY BE <br />REQUIRED TO MAKE PLUMB AND SQUARE AND TO <br />PROVIDE 3/" MIN. GAP AROUND ALL SIDE.SZYP. <br />STEP B: SILL FLASHING & CORNER BOOTS <br />STEP F: SEAL WINDOW FLANGES TO PENETRATION WRAP <br />SCALE:NTS <br />SCALE:NTS <br />CUT AND FOLD PENETRATION <br />FLASHING INTO ROUGH OPENING, <br />MINIMUM 4". PENETRATION FLASHING <br />@ JAMBS TO BE WRB, TYP. <br />TAPE BOTTOM EDGE OF JAMB <br />FLASHING, PER AIR REQUIREMENTS <br />STEP C: JAMB PENETRATION FLASHING <br />SCALE:NTS <br />V) <br />M <br />O <br />N <br />ui <br />0') <br />LN <br />Z <br />z <br />� O <br />0 V <br />z <br />LLl <br />JU <br />Lu <br />0 <br />(If <br />LLJ LLJ <br />LLJ LLJ <br />• • v <br />0 <br />• • • N <br />r <br />0 <br />cn <br />m � <br />44�d <br />E <br />0 <br />o <br />�m <br />c r <br />maD <br />o r m <br />Or U <br />> M <br />m M > <br />Q <br />a <br />N <br />0 00 0 <br />a) <br />N N <br />3 <br />co co 3 <br />0 <br />O N <br />00 3 <br />N N <br />N a1 <br />N cn <br />3 <br />WINDOW WRAP <br />SEQUENCE <br />2020-1009 PERMIT SET <br />THE UNDERSIGNED HAS PROVIDED <br />BUILDING ENCLOSURE DOCUMENTS <br />THAT, IN MY PROFESSIONAL <br />JUDGEMENT, ARE APPROPRIATE <br />TO <br />SATISFY THE REQUIREMENTS OF RCW <br />64.55.005 THROUGH 64.55.090. <br />COPYRIGHT ©2019 OAC SERVICES, INC. <br />THESE DOCUMENTS, THE IDEAS AND DESIGNS INCORPORATED <br />HEREIN AS AN INSTRUMENT OF SERVICE, ARE THE PROPERTY OF <br />OACSERVICES, INC. ANDARE NOT TO REUSED INAHOLEORIN <br />PART WITHOUT WRITTEN AUTHORIZATION OF OAC SERVICES, INC <br />DESIGN <br />KRM <br />DRAWN <br />KRM <br />CHECK <br />XBE5,00 <br />CAC PROJ. No. <br />R12-2o0��70� <br />
The URL can be used to link to this page
Your browser does not support the video tag.