Laserfiche WebLink
CLADDING, AS SCHEDULED <br />WRB, LAP o/ AND SEAL TO <br />VERT. LEG OF FLASHING <br />24 GA. PRE -FINISHED SM <br />FLASHING w/ HEMMED <br />DRIP AND FOLDED END <br />DAMS <br />FLASHING TAPE o/ HEAD <br />FLANGE <br />TRIM, PER ARCH. <br />WINDOW, PER SCHEDULE <br />ys' SHIMS UNDER <br />WINDOW FLANGE FOR <br />DRAINAGE <br />TRIM, PER ARCH. <br />SEALANT FILLET <br />PENETRATION FLASHING <br />WRB, LAP o/ AND SEAL TO <br />VERT. LEG OF FLASHING <br />CLADDING, AS SCHEDULED <br />RIGID INSULATION @ <br />FACE OF SLAB, PER <br />ARCH. <br />24 GA. PRE -FINISHED SM <br />FLASHING w/ HEMMED <br />DRIP <br />TYPICAL WALL ASSEMBLY @ SLAB OVERHANG <br />SCALE:NTS <br />WRB TO LAP ONTO SIDE <br />DAMS OF SILL PAN OR SILL <br />WATERPROOFING, TYP. <br />DOOR FRAME, TYP. <br />SEALANT. TYP. <br />SAM/ TAPE TO DOOR FRAME, <br />TYP. <br />TRIM, AS SCHEDULED <br />NOTE: <br />1. WINDOW TO WINDOW TRANSOM SIMILAR. <br />FILL VOID BETWEEN PENETRATION <br />FLASHING AND DOOR FRAME w/ <br />NON -EXPANDING CLOSED -CELL <br />SPRAY FOAM (AIR SEAL) <br />VERTICAL TRANSOM @ WINDOW/ <br />SCALE:NTS <br />SET THRESHOL9 IN <br />CONTINUOUS SEALANT, <br />1 <br />I � <br />I Q <br />D' <br />I a <br />5 UNIT DECK DOOR THRESHOLD <br />SCALE:NTS <br />D INSULATION <br />)CONCRETE <br />\RRIER). TAPE ALL <br />D EDGES, TYP. <br />R ARCH. <br />= I <br />Q I <br />� I <br />a I <br />SPRAY FOAM @ <br />RIM <br />INTERIOR SEALANT JOINT w/ <br />BACKER ROD. TYP. <br />WINDOWASSEMBLY, PER <br />SCHEDULE <br />SAM o/ WINDOW FLANGE, TYP. <br />PENETRATION FLASHING, <br />TYP. @ EA. SIDE <br />TYP <br />L2 SLAB <br />COMPOSITE DOOR, PER <br />SCHEDULE <br />P.T. CONCRETE DECK, PER <br />STRUCT. <br />1 ' 1mr�T11 '-i-C7G �►I� <br />SLOPE Y4":12" MIN. <br />COMPOSITE DOOR, PER <br />SCHEDULE <br />SET THRESHOLD IN <br />CONTINUOUS SEALANT, TYP <br />3/" MIN. SE, <br />JOINT w/ BACKEI <br />CONT. <br />SHOULDEF <br />WINDOW HEAD, TYP <br />SCALE:NTS <br />%" MIN. SEALANT <br />JOINT w/ BACKER <br />ROD CONT. @ INT. <br />SHOULDER. TYP. <br />WINDOWASSEMBLY, PER <br />SCHEDULE <br />SEAL FLANGE TO PENETRATION <br />FLASHING, TYP. @ JAMB <br />SEAL WRB o/ FLANGE w/ SAM, TYP. <br />(REF. SHEET XBE5.00, TYP.) <br />WINDOW JAMB, TYP. <br />SCALE:NTS <br />SET ON Y" COMPOSITE <br />SHIMS - SET SHIMS PER <br />MANUF. REQUIREMENTS <br />AND ORIENT T <br />FOR CONT. INTER <br />(O DECK WP MEMBRANE - <br />CONTINUOUS INTO SILL AND 6" 3/a" MIN. SEALA <br />MIN. UP JAMBS w/ BACKER R( <br />@ INT. SHOUL[ <br />SLOPEy":12" MIN. <br />DECK FRAMING <br />WRB TARGET - CONTINUOUS <br />BEHIND DECK LEDGER, TYP. <br />NOTE: <br />1. IF SILL FLANGE REMOVAL <br />REQUIRED, VERIFY WARRANTY <br />WITH SLIDING GLASS DOOR <br />MANUFACTURER. <br />UNIT DECK DOOR THRESHOLD @ FRAMED DECK, TYP. �� 1 WINDOW SILL, TYP <br />SCALE:NTS <br />SCALE:NTS <br />CLADDING, AS SCHEDULED <br />WRB, LAP o/ AND SEAL TO VERT. <br />LEG OF FLASHING <br />PENETRATION FLASHING <br />24 GA. PRE -FINISHED SM <br />FLASHING w/ Y2" END DAMS <br />AND DRIP. BED IN SEALANT, <br />TYP. <br />SAM o/ HEAD FLANGE <br />FASTEN HEAD FLANGE, PER <br />MANUF. REQUIREMENTS <br />TRIM, AS SCHEDULED <br />SEAL FLANGE CONTINUOUSLY TO <br />PENETRATION FLASHING, TYP. <br />WINDOWASSEMBLY, PER <br />SCHEDULE <br />WRB (FIELD) <br />CLADDING, AS SCHEDULED <br />PENETRATION FLASHING <br />TRIM, AS SCHEDULED <br />WINDOWASSEMBLY, PER <br />SCHEDULE <br />SEALANT JOINT BETWEEN TRIM <br />AND WINDOW @ JAMBS AND SILL, <br />TYP. SEE DETAIL 2/XBE5.01 <br />Y,s' SHIMS @ FASTENERS UNDER <br />SILL FLANGE TO DRAIN <br />TRIM. AS SCHEDULED <br />SILL FLASHING BIB, PER WINDOW <br />WRAP SEQUENCE SHEET XBE5.00 <br />WRB, FROM BELOW <br />SEAM BOT. EDGE OF BIB TO WRB <br />(AIR SEAL) <br />CLADDING, AS SCHEDULED <br />V) <br />01. <br />M <br />O <br />N <br />ui <br />0') <br />LID <br />Z <br />zfn <br />� O <br />0 V <br />z <br />U) <br />Z <br />w <br />J <br />U' w <br />0 <br />(If <br />w w <br />W W <br />0 <br />• • • N <br />r <br />0 <br />cl) <br />m � <br />E <br />0 <br />o <br />�m <br />c r <br />NCID <br />o r m <br />Or 0 <br />> m <br />(h M > <br />Q <br />a <br />N <br />-3 <br />U)I� <br />co co 0 <br />' <br />N N <br />. . 3 <br />— <br />co <o 3 <br />0 <br />O N <br />00 3 <br />N N <br />N U) <br />N W <br />3 <br />WINDOW & <br />DOOR DETAILS <br />2020-1009 PERMIT SET <br />THE UNDERSIGNED HAS <br />PROVIDED <br />BUILDING ENCLOSURE DOCUMENTS <br />THAT, IN MY PROFESSIONAL <br />JUDGEMENT, ARE APPROPRIATE TO <br />SATISFY THE REQUIREMENTS OF RCW <br />64.55.005 THROUGH 64.55.090. <br />COPYRIGHT© 2019 OAC SERVICES, INC. <br />THESE DOCUMENTS, THE IDEAS AND DESIGNS INCORPORATED <br />HEREIN AS AN INSTRUMENT OF SERVICE, ARE THE PROPERTY OF <br />OAC SERVICES, INC. AND ARE NOT TO BE USED IN WHOLE OR IN <br />PART WITHOUT WRITTEN AUTHORIZATION OF OAC SERVICES, INC <br />DESIGN <br />KRM <br />DRAWN <br />KRM <br />CHECK <br />XBE5,01 <br />OAC PROJ. No. <br />