Laserfiche WebLink
NOT USED <br />NOT USED <br />SCALE: NTS \ ' / SCALE:NTS <br />NOT USED <br />SCALE: NTS <br />NOT USED <br />SCALE: NTS <br />SEALANT JOINT w/ <br />BACKER ROD <br />ALUM. SF ASSEMBLY, <br />PER SCHEDULE <br />MIN. SEALANT JOINT w/ BACKER <br />ROD - DO NOT BLOCK WEEPS <br />24 GA. PRE -FINISHED SM FLASHING <br />w/ HEMMED EDGE SPRUNG TO <br />MASONRY CAP <br />PENETRATION FLASHING <br />MASONRY VENEER, AS <br />SCHEDULED <br />WRB, SEAL BOTTOM EDGE <br />(AIR BARRIER) <br />TAPE VERT. LEG OF WEEP <br />SCREED TO WRB, TYP. <br />WEEP SCREED <br />:fY <br />FIELD WRB <br />FURRING. AS SCHEDULED <br />CLADDING, AS SCHEDULED <br />ALUM. STOREFRONT DOOR JAMB, TYP. <br />SCALE: NTS <br />�J <br />a s <br />a a a <br />a . <br />WINDOWSILL @ MASONRY VENEER, TYP. 6 ALUM. STOREFRONT SILL <br />SCALE: NTS REF. DETAILS 2,3/XBE5.07, TYP. SCALE: NTS <br />gum <br />ZIP <br />SEALANT JOINT w/ BACKER ROD <br />FOIL -FACED SAM PENETRATION <br />FLASHING, TYP. <br />ALUM. SF DOOR, PER <br />SCHEDULE <br />SEALANT JOINT w/ <br />BACKER ROD <br />— 24 GA. PRE -FINISHED SM JAMB <br />FLASHING - BED INT. LEG IN <br />SEALANT, TYP. <br />%" SEALANT JOINT w/ BACKER ROD <br />ALUM. SF DOOR, AS SCHEDULED <br />SEALANT w/ BACKER ROD <br />.025" SSTL (IF EXPOSED)/ 24 GA. GALV. G-90 <br />(IF CONCEALED) SILL PAN w/ HEMMED DRIP. <br />SET IN (3) CONTINUOUS BEADS OF SEALANT, <br />TYP. <br />SEALANT w/ BACKER ROD <br />COMPRESSIBLE FILLER, TYP. <br />SLAB, TYP <br />%" SEALANT JOINT <br />w/ BACKER ROD <br />WRB LAP o/ AND SEAL TO <br />VERT. LEG OF FLASHING <br />CLADDING. AS SCHEDULED <br />FOIL -FACED SAM PENETRATION <br />FLASHING <br />24 GA. PRE -FINISHED SM <br />FLASHING w/ HEMMED DRIP <br />INSECT SCREEN <br />24 GA. PRE -FINISHED CLEAT - <br />BED IN SEALANT TO FA PF, <br />TYP. <br />ALUM. SF ASSEMBLY, PER <br />SCHEDULE <br />ALUM. STOREFRONT HEAD, TYP. <br />SCALE: NTS <br />SEALANT JOINT w/ BACKER ROD <br />ALUM. SF ASSEMBLY, PER <br />SCHEDULE <br />0 <br />FURRING, AS SCHEDULED <br />CLADDING, AS SCHEDULED <br />SEALANT JOINT w/ <br />BACKER ROD <br />— 24 GA. PRE -FINISHED SM JAMB <br />FLASHING - BED INT. LEG IN <br />SEALANT, TYP. <br />%" SEALANT JOINT w/ BACKER ROD <br />FOIL -FACED SAM PENETRATION FLASHINC <br />ALUM. STOREFRONT JAMB, TYP. <br />SCALE: NTS <br />3/" MIN. SEALANT w/ <br />BACKER ROD, TYP. <br />0 <br />M <br />ALUM. STOREFRONT SILL <br />SCALE: NTS <br />G <br />n <br />GRADE, TYP. <br />ALUM. SF ASSEMBLY, PER <br />SCHEDULE <br />MIN. SEALANT JOINT w/ BAC <br />ROD - DO NOT BLOCK WEEPS <br />24 GA. PRE -FINISHED SM <br />FLASHING SPRUNG TO <br />SIDEWALK- VERIFY DEPTH OF <br />FLASHING w/ ARCH. SET IN BEC <br />OF SEALANT TO PENETRATION <br />FLASHING <br />V) <br />co <br />O <br />N <br />ui <br />0') <br />LN <br />Ifn Z <br />Z <br />� O <br />LL <br />0 CD <br />z <br />z <br />C) <br />, <br />J <br />U' Lu <br />0 <br />(If <br />LLJ LLJ <br />W W <br />• • v <br />0 <br />0 0 0 N <br />• • • r <br />0 <br />cl) <br />m <br />E <br />0 <br />0 <br />�m <br />c r <br />maD <br />o r m <br />Or U <br />> m <br />m M > <br />Q <br />a <br />N <br />-3 <br />L0Iw <br />0 00 0 <br />a) <br />N N <br />. . 3 <br />U- — <br />co <o 3 <br />0 <br />O N <br />0 <br />00 3 <br />N N <br />N a <br />N W <br />3 <br />WINDOW & <br />DOOR DETAILS <br />2020-1009 PERMIT SET <br />THE UNDERSIGNED HAS <br />PROVIDED <br />BUILDING ENCLOSURE DOCUMENTS <br />THAT, IN MY PROFESSIONAL <br />JUDGEMENT, ARE APPROPRIATE TO <br />SATISFY THE REQUIREMENTS OF RCW <br />64.55.005 THROUGH 64.55.090. <br />COPYRIGHT© 2019 OAC SERVICES, INC. <br />THESE DOCUMENTS, THE IDEAS AND DESIGNS INCORPORATED <br />HEREIN AS AN INSTRUMENT OF SERVICE, ARE THE PROPERTY OF <br />OAC SERVICES, INC. AND ARE NOT TO BE USED IN WHOLE OR IN <br />PART WITHOUT WRITTEN AUTHORIZATION OF OAC SERVICES, INC <br />DESIGN <br />KRM <br />DRAWN <br />KRM <br />CHECK <br />XBE5,03 <br />OAC PROJ. No. <br />R12-200117.01 <br />