Laserfiche WebLink
I <br /> I <br /> i <br /> 1 .0 The Isolator Row <br /> I 1.1 INTRODUCTION The Isolator Row is typically designed to capture the <br /> An important component of any Stormwater Pollution "first flush"and offers the versatility to be sized on a vol- <br /> Prevention Plan is inspection and maintenance.The ume basis or flow rate basis. An upstream manhole not <br /> I StormTech Isolator Row is a patent pending technique only provides access to the Isolator Row but typically <br /> to inexpensively enhance Total Suspended Solids(TSS) includes a high flow weir such that storm water flowrates <br /> removal and provide easy access for inspection and or volumes that exceed the capacity of the Isolator Row <br /> maintenance. overtop the over flow weir and discharge through a <br /> I <br /> manifold to the other chambers. <br /> The Isolator Row may also be part of a treatment train. <br /> s, \\' s, <br /> By treating storm water prior to entry into the chamber <br /> system, the service life can be extended and pollutants <br /> such as hydrocarbons can be captured. Pre-treatment <br /> best management practices can be as simple as deep <br /> sump catch basins, oil-water separators or can be inno- <br /> (00.-7/. <br /> vative storm water treatment devices. The design of <br /> I <br /> the treatment train and selection of pretreatment devices <br /> Z by the design engineer is often driven by regulatory <br /> requirements.Whether pretreatment is used or not,the <br /> Isolator Row is recommended by StormTech as an <br /> effective means to minimize maintenance requirements <br /> and maintenance costs. • <br /> I - <br /> Note:See the StormTech Design Manual for detailed <br /> Looking down the Isolator Row from the manhole opening, woven information on designing inlets for a StormTech system, <br /> geotextile is shown between the chamber and stone base. including the Isolator Row. <br /> 1.2 THE ISOLATOR`"ROW I The Isolator Row is a row of StormTech chambers, either Stor Tech Isolator Row with Overflow Spillway <br /> (not to scale) <br /> SC-310, SC-740 or MC-3500 models,that is surrounded OPTIONAL <br /> with filter fabric and connected to a closely located man- PRE-TREATMENT <br /> Ihole for easy access. The fabric-wrapped chambers <br /> provide for settling and filtration of sediment as storm <br /> water rises in the Isolator Row and ultimately passes STORMTECH <br /> I through the filter fabric.The open bottom chambers and ISOLATOR ROW <br /> perforated sidewalls allow storm water to flow both verti- <br /> cally and horizontally out of the chambers. Sediments � � N.'. <br /> are captured in the Isolator Row protecting the storage MANHOLE =I <br /> areas of the adjacent stone and chambers from sedi- WITH = i <br /> ment accumulation. OVERFLOW <br /> WEIR f 1 <br /> Two different fabrics are used for the Isolator Row. A <br /> I woven geotextile fabric is placed between the stone = : r <br /> and the Isolator Row chambers.The tough geotextile \ <br /> provides a media for storm water filtration and provides ECCENTRIC zr J <br /> a durable surface for maintenance operations. It is also — 1 <br /> designed to prevent scour of the underlying stone and J <br /> remain intact during high pressure jetting.A non-woven r ) <br /> fabric is placed over the chambers to provide a filter — ) <br /> media for flows passing through the perforations in the — r <br /> I sidewall of the chamber. <br /> OPTIONAL --� <br /> ACCESS -STORMTECH CHAMBERS <br /> 2 Call StormTech at 888.892.2694 or visit our website at www.stor tech.co for technical and product information. <br /> I <br />