I <br /> I 2.0 Isolator Row Inspection/Maintenance StormTech- <br /> I2.1 INSPECTION <br /> The frequency of Inspection and Maintenance varies `\ <br /> is‘....7 774 <br /> by location.A routine inspection schedule needs to be <br /> U <br /> established for each individual location based upon site w�. ! <br /> specific variables.The type of land use(i.e. industrial, <br /> commercial residential), anticipated pollutant load, per- <br /> cent imperviousness, climate, etc. all play a critical role <br /> I in determining the actual frequency of inspection and <br /> maintenance practices. <br /> . : : <br /> At a minimum, StormTech recommends annual inspec- MVP ISE <br /> ' tions. Initially,the Isolator Row should be inspected every <br /> 6 months for the first year of operation. For subsequent <br /> years, the inspection should be adjusted based uponli '---1 i,r " ' , <br /> previous observation of sediment deposition. t <br /> I The Isolator Row incorporates a combination of standard <br /> manhole(s)and strategically located inspection ports <br /> (as needed).The inspection ports allow for easy access Examples of culvert cleaning nozzles appropriate for Isolator Row <br /> to the system from the surface, eliminating the need to maintenance.(These are not StormTech products.) <br /> perform a confined space entry for inspection purposes. <br /> Maintenance is accomplished with the JetVac process. <br /> If upon visual inspection it is found that sediment has The JetVac process utilizes a high pressure water noz- <br /> accumulated, a stadia rod should be inserted to deter- zle to propel itself down the Isolator Row while scouring <br /> I mine the depth of sediment. When the average depth and suspending sediments. As the nozzle is retrieved, <br /> of sediment exceeds 3 inches throughout the length of the captured pollutants are flushed back into the man- <br /> the Isolator Row, clean-out should be performed. hole for vacuuming. Most sewer and pipe maintenance <br /> I <br /> companies have vacuum/JetVac combination vehicles. <br /> 2.2 MAINTENANCE Selection of an appropriate JetVac nozzle will improve <br /> The Isolator Row was designed to reduce the cost of maintenance efficiency. Fixed nozzles designed for cul- <br /> periodic maintenance. By"isolating" sediments to just verts or large diameter pipe cleaning are preferable. <br /> I one row, costs are dramatically reduced by eliminating Rear facing jets with an effective spread of at least 45" <br /> the need to clean out each row of the entire storage are best. Most JetVac reels have 400 feet of hose allow- <br /> bed. If inspection indicates the potential need for main- ing maintenance of an Isolator Row up to 50 chambers <br /> tenance, access is provided via a manhole(s) located long. The JetVac process shall only be perfor ed on <br /> I on the end(s)of the row for cleanout. If entry into the Stor Tech Isolator Rows that have AASHTO class 1 <br /> manhole is required, please follow local and OSHA rules woven geotextile (as specified by Stor Tech) over <br /> for a confined space entries. their angular base stone. <br /> I Stor Tech Isolator Row(not to scale) <br /> COVER ENTIRE ROW WITH AASHTO M288 <br /> INSPECTION PORT CLASS 2 NON-WOVEN GEOTEXTILE <br /> LOCATION PER ENGINEER'S SC-310-5'(1.5 m)WIDE STRIP <br /> DRAWING SC-740-8'(2.4 m)WIDE STRIP STORMTECH <br /> I MG3500-12.5'(3.8 m)WIDE STRIP END CAP <br /> CATC�, -- - ��� ' <br /> At <br /> BASIN - - 11111111I1-jill <br /> OR MANHOLE - iPPAMIIM111... M <br /> X,.�= III= <br /> Illinir-` �AIAIAIAIAIAIAIAI�►�ifAi 'AIAIAIAIAIAIAIAIAIA�•' 17 4'f& <br /> INV il?:;1141.00100101PlifittliffliektIONIVitil�lil�lil�lil�liIVi Y ' d <br /> SUMP DEPTH <br /> " ..r...'!i.�� <br /> I <br /> BY DESIGN 11=11=11. •:-• 1=11 Ilu, <br /> ENGINEER <br /> SC -12"(300 mm)PIPE 2 LAYERS OF WOVEN GEOTEXTILE THAT MEETS AASHTO M288 CLASS 1 <br /> SC-740-24"(600 mm)PIPE REQUIREMENTS,BETWEEN STONE BASE AND CHAMBERS <br /> MC3500-24"(600 mm)PIPE SC-310-4'(1.2 m)WIDE STRIP <br /> SC-740-5'-6'(1.5 m)WIDE STRIP <br /> I - - MC-3500-8.25'(2.5 m)WIDE STRIP <br /> Call StormTech at 888.892.2694 or visit our website at www.stor tech.co for technical and product information. 3 <br /> I <br />