My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
202 ALDER ST Geotech Report 2025-07-30 (2)
>
Address Records
>
ALDER ST
>
202
>
Geotech Report
>
202 ALDER ST Geotech Report 2025-07-30 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2025 2:44:57 PM
Creation date
7/30/2025 2:43:20 PM
Metadata
Fields
Template:
Address Document
Street Name
ALDER ST
Street Number
202
Notes
PRELIMINARY
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Proposed View Ridge Subsurface Exploration, Geologic Hazards, Infiltration Potential, <br /> Elementary School Replacement and Preliminary Geotechnical Engineering Report <br /> Everett, Washington Preliminary Design Recommendations <br /> drainage conditions where site grades will slope towards pavement edges or building areas, <br /> since surface water and perched seepage might be directed towards these structures. If site <br /> grades will slope toward pavement edges or structures, it would be appropriate to include <br /> cutoff drains in project plans. We should be allowed to offer situation-specific <br /> recommendations for these drains once a grading plan has been finalized. For planning <br /> purposes, cutoff drains should be located outside of the building perimeter(s) and pavement <br /> edges, and should extend to depths sufficient to achieve a minimum 1 foot of penetration into <br /> the underlying advance outwash. The cutoff drains should be at least 18 inches wide, should <br /> be graded to drain by gravity to a suitable discharge location, and should be provided with a <br /> perforated pipe surrounded by washed drain rock. For the planned south driveway, the drain <br /> for the expected south retaining wall may serve as an effective cutoff drain, depending on final <br /> design. <br /> 12.0 FLOOR SUPPORT <br /> Floor slabs can be supported on suitable native sediments, or on structural fill placed above <br /> suitable native sediments. Floor slabs should be cast atop a minimum of 4 inches of clean, <br /> washed, crushed rock or pea gravel to act as a capillary break. Areas of subgrade that are <br /> disturbed (loosened) during construction should be compacted to a non-yielding condition prior <br /> to placement of capillary break material. Floor slabs should also be protected from dampness <br /> by an impervious moisture barrier at least 10 mils thick. The moisture barrier should be <br /> placed between the capillary break material and the concrete slab. <br /> 13.0 FOUNDATION WALLS <br /> All backfill behind foundation walls or around foundation units should be placed as per our <br /> recommendations for structural fill and as described in this section of the report. Horizontally <br /> backfilled walls, which are free to yield laterally at least 0.1 percent of their height, may be <br /> designed to resist active lateral earth pressure represented by an equivalent fluid equal to 35 <br /> pounds per cubic foot (pcf). Fully restrained, horizontally backfilled, rigid walls that cannot <br /> yield should be designed for an equivalent fluid of 50 pcf. Walls with sloping backfill up to a <br /> maximum gradient of 2H:1V should be designed using an equivalent fluid of 55 pcf for <br /> yielding conditions or 75 pcf for fully restrained conditions. If parking areas are adjacent to <br /> walls, a surcharge equivalent to 2 feet of soil should be added to the wall height in determining <br /> lateral design forces. <br /> As required by the 2009 IBC, retaining wall design should include a seismic surcharge <br /> pressure in addition to the equivalent fluid pressures presented above. Considering the site <br /> September 22, 2010 ASSOCIATED EARTH SCIENCES, INC. <br /> DWG/tb-KE100255A2-Projects120100255IKElWP Page 19 <br />
The URL can be used to link to this page
Your browser does not support the video tag.