8102 EVERGREEN WAY EVERETT 4 CORNERS - BLDG E 2025-08-06
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG E
>
8102 EVERGREEN WAY EVERETT 4 CORNERS - BLDG E 2025-08-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2025 8:58:29 AM
Creation date
8/4/2025 3:08:09 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG E
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
331
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM: SPF-2 <br />AREA SERVED: STAIR #2 <br />Fan Information <br />1. <br />Rated voltage: 208 <br />2. Actual Operating Voltage: 211 <br />3. <br />Rated Amperage: 5.6 <br />4. Actual Operating Amperage: 1.4 <br />5. <br />Fan RPM: 27.0 HZ <br />6. Number Fan Belts: DIRECT DRIVE <br />7. <br />Fan Belts Condition: DIRECT DRIVE <br />Measurements Taken <br />Floor <br />Inches Hz0 <br />Floor <br />Inches <br />H2O <br />Floor <br />Door Force <br />(LBS) <br />Floor <br />Door Force <br />(LBS.) <br />G-OUTSIDE <br />0.16 <br />5TH <br />0.16 <br />G- <br />OUTSIDE <br />8 <br />5TH <br />23 <br />G-PARKING <br />0.16 <br />6TH <br />0.16 <br />G- <br />PARKING <br />8 <br />6TH <br />25 <br />2ND <br />0.16 <br />2ND <br />22 <br />3RD <br />0.16 <br />3RD <br />27 <br />4TH <br />0.16 <br />4TH <br />27 <br />General <br />16. Do stair shafts have flush? CFM <br />17. Were measurements taken from atmospheric pressure? <br />18. Were measurements taken from shaft and the main occupied area? <br />19. What was static pressure? _0.16 in. H2O <br />20. Were readings taken at every 5th floor? <br />21. Do fans operate when fire alarm is activated? <br />22. Do fans operate on emergency power? <br />23. If no sprinklers, is elevator shaft pressure 0.15 in H2O or greater? <br />24. Do elevator shaft pressures measure 0.10 in H2O, in 100% automatic <br />sprinklered building? <br />25.All doors (stairway and elevator) operate correctly? <br />26. System can be operated manually? <br />27. Does life safety core type building have 0.05 in H2O between pressurized <br />core and tenant area? <br />28.Are gaskets in good condition on stair and elevator doors? <br />29. Do all dampers, controls work properly on shaft pressurization system? <br />30. Do stair shaft pressures measure 0.10 in H2O? <br />Additional Measurements, Calculations and Comments: <br />EMERGENCY POWER TEST PERFORMED BY OTHERS. <br />YES <br />NO <br />N/A <br />❑ <br />❑ <br />® <br />❑ <br />❑ <br />® <br />❑ <br />❑ <br />® <br />❑ <br />❑ <br />® <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />® <br />❑ <br />❑ <br />® <br />❑ <br />❑ <br />❑ <br />❑ <br />® <br />❑ <br />❑ <br />® <br />❑ <br />❑ <br />® <br />❑ <br />❑ <br />Shaft Pressurization Page 4 of 4 <br />