My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10930 HOLLY DR Geotech Report 2025-08-08
>
Address Records
>
HOLLY DR
>
10930
>
Geotech Report
>
10930 HOLLY DR Geotech Report 2025-08-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2025 9:49:44 AM
Creation date
8/8/2025 9:44:07 AM
Metadata
Fields
Template:
Address Document
Street Name
HOLLY DR
Street Number
10930
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�." �.`��%'•° 1 ,, c �:ice fro. � „�'t�.:: it',,�,..t. S -.,�^ �'. fi 'Fc.=- ''*t T • <br /> • <br /> Helix Design.Group,Inc.-Greenwood Heating Sr Air Conditioning,Everett,WA April 22,2022 <br /> Geotechnical Engineering Report Z0219 <br /> 5.0 RECOMMENDED ADDITIONAL SERVICES <br /> Because the future performance and integrity of the structural elements will depend largely on <br /> proper site preparation, drainage, fill placement, and construction procedures, monitoring and <br /> testing by experienced geotechnical personnel should be considered an integral part of the <br /> construction process. Subsequently,we recommend that MGI be retained to provide the following <br /> post-report services: <br /> • Review all construction plans and specifications to verify that our design criteria presented <br /> in this report have been properly integrated into the design; <br /> • Prepare a letter summarizing all review comments (if required); <br /> • Check all completed subgrades for footings and slab-on-grade floors before concrete is <br /> poured, in order to verify their bearing capacity; and <br /> • Prepare a post-construction letter summarizing all field observations,inspections,and test <br /> results (if required). <br /> 6.0 CLOSURE <br /> The conclusions and recommendations presented in this report are based, in part, on the <br /> explorations that we observed for this study;therefore,if variations in the subgrade conditions are <br /> observed at a later time,we may need to modify this report to reflect those changes. Also,because <br /> the future performance and integrity of the project elements depend largely on proper initial site <br /> preparation, drainage, and construction procedures, monitoring and testing by experienced <br /> geotechnical personnel should be considered an integral part of the construction process. MGI is <br /> available to provide geotechnical monitoring of soils throughout construction. <br /> We appreciate the opportunity to be of service on this project. If you have any questions regarding <br /> this report or any aspects of the project,please feel free to contact our office. <br /> Respectfully submitted, <br /> MIGIZI GROUP, INC. <br /> „„, do,/ <br /> rdp 20646:50, <br /> eo <br /> . 04/22/22 <br /> 1Logan,L.G. James E.Brigham, P.E. <br /> 'roject Geologist Principal Engineer <br /> Migizi Group,Inc. Page 16 of 16 <br />
The URL can be used to link to this page
Your browser does not support the video tag.