My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2309 PINE ST 2025-08-21
>
Address Records
>
PINE ST
>
2309
>
2309 PINE ST 2025-08-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/21/2025 1:27:39 PM
Creation date
8/8/2025 11:58:48 AM
Metadata
Fields
Template:
Address Document
Street Name
PINE ST
Street Number
2309
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
127
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> PINE STREET HOUSE I February 15, 2020 SDA Job# 8910 1 7 <br /> . FRONT SEGMENTED SHEARWALL WIND SEISMIC <br /> ' Floor Info Tributary Area(ROOF) Tributary Area(ROOF) <br /> ROOF Floor Level,e.g.Roof,4TH,3RD,2ND 1 0 tributary width 1 0 tributary area <br /> Lt-Rt Load Direction,e.g.Left-Right,Front-Rear 2 0 total width 2 0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Area(NA) Tributary Area(NA) <br /> r CDX Sheathing type(T4.3A of SDPWS-2015) tributary width tributary area <br /> total width total area <br /> ROOF Resisting Dead Load Tributary Area(NA) Tributary Area(NA) <br /> Shearwall Segment Lengths: Adj,Total Length= 10.4 ft tributary width tributary area <br /> I 3,0 ft I 4.0 ft I 4.0 ft } I I total width total area <br /> Tributary Area(NA) Tributary Area(NA) <br /> IV(ROOF)= 6424 lb 3918 lb Htributary width tributary area <br /> IV()= 0 lb 0 lb total width total area <br /> IV O= O lb 0 1b <br /> IV O= 0 lb 0 lb Height of Shearwall= 9.0 ft Weight of Shearwall= 10.0 lbs <br /> I(Wind)= 6,424 lb E(Smc)= 3,918 lb Length of Shearwall= 3 0 ft Tributary width for dead load= 185 ft <br /> ULT.v= 310 PLF ULT. V= 189 PLF Aspect Ratio OK Length of adjoining wall= 4 5 ft <br /> Use alternate R factor for seismic? No R= 6 5 <br /> ASD SHEAR WALL DESIGN PER:AF&PA SDPWS-2015 DO Holdown Design? No Do= 2.5 <br /> WIND CAPACITY:1.4 x 0.93 x 460 PLF/(2 x 0.6)=499 PLF Ductile Anchor Design?, No Block Shear Wall <br /> SEISMIC CAPACITY:1 x 0.93 x 460 PLF/(2 x 0.7)=305 PLF USE A <br /> Floor Above:[ NO FLOOR ABOVE t•4/)1lc controls sheart•`all design <br /> ASD C.TOTAL= (floor above)+(this floor)= 0 lbs + 1672 lbs = 1672 lbs Wind controls-C1(ASD eq,5): <br /> ASD T. TOTAL w/o D0= (floor above)+(this floor)= 0 lbs + 935 lbs = 935 lbs Wind controls-T1(ASD eq,7): <br /> Unfactored C.WL=2786 lbs Unfactored T.WL=3764 lbs I SIMPSON DESIGNED HOLDOWN: CS14 <br /> Unfactored C.EQ=1699 lbs Unfactored T.EQ=1699 lbs ) FOUNDATION/INTERIOR WALLS: I LSTHDB/RJ J <br /> Unfactored C DL= 2205 lbs Unfactored C,LL/SL=2775 lbs I <br /> REAR SEGMENTED SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Area(ROOF) Tributary Area(ROOF) <br /> 1 ROOF Floor Level,e.g.Roof,3RD,2ND,1ST.. 1.0 tributary width 1.0 tributary area <br /> Lt-Rt Load Direction,e.g.Left-Right,Front-Rear 2 0 total width 2.0 total area <br /> (For Left Wall.Use Front-Rear Load Direction) Tributary Area(NA) Tributary Area(NA) <br /> CDX Sheathing type(T4.3A of SDPWS-2015) 1.0 tributary width 1.0 tributary area <br /> 2 0 total width 2.0 total area <br /> ROOF Resisting Dead Load Tributary Area(NA) Tributary Area(NA) <br /> Shearwall Segment Lengths: Adj.Total Length= 22 0 ft tributary width tributary area <br /> 9.5 ft I 5.8 ft 1 4 8 ft I 3 0 ft I I total width total area <br /> Tributary Area(NA) Tributary Area(NA) <br /> IV(ROOF)= 6424 lb 3918 lb tributary width tributary area <br /> IV()= 0 lb 0 lb total width total area <br /> IV()= 0lb 0lb <br /> IV O= 0 lb 0 lb Height of Shearwall= 9 0 ft Weight of Shearwall= 10.0 lbs <br /> I(Wind)= 8,424 lb I(Smc)= 3,918 lb Length of Shearwall= 3 0 ft Tributary width for dead load= 18.5 ft <br /> ULT.v= 146 PLF ULT. v= 89 PLF Aspect Ratio OK Length of adjoining wall= 4.5 ft <br /> Use alternate R factor for seismic? No R= 6 5 <br /> ASD SHEAR WALL DESIGN PER:AF&PA SDPWS-2015 DO Holdown Design? No Go= 2.5 <br /> WIND CAPACITY:1.4 x 0.93 x 460 PLF 1(2 x 0.6)=499 PLF Ductile Anchor Design? No A Block Shear Wall <br /> SEISMIC CAPACITY:1 x 0.93 x 460 PLF/(2 x 0.7)=305 PLF USE <br /> Floor Above: NO FLOOR ABOVE blond controls strea,wal(design <br /> ASD C.TOTAL= (floor above)+(this floor)= 0 lbs + 815 lbs = 815 lbs Seismic controls-C3(ASD eq.8): <br /> ASD T. TOTAL w/o 00= (floor above)+(this floor)= 0 lbs + 52 lbs = 52 lbs Wind controls-T1(ASD eq 7): <br /> Unfactored C.WL=1314 lbs Unfactored T.WL=2291 lbs i NO HOLDOWNS REQUIRED ( OK I <br /> Unfactored C.EQ=801 lbs Unfactored T.EQ=801 lbs FOUNDATION/INTERIOR WALLS: I _OK_ J <br /> Unfactored C.DL= 2205 lbs Unfactored C,LUSL=2775 lbs <br />
The URL can be used to link to this page
Your browser does not support the video tag.