Laserfiche WebLink
PINE STREET HOUSE February 15, 2020 SDA Job# 8910 8 <br /> LEFT SEGMENTED SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Area(ROOF) Tributary Area(ROOF) <br /> ROOF Floor Level,e.g.Roof,3RD,2ND,1ST.. 1 0 'tributary width 1 0 tributary area <br /> NMI Load Direction,e.g.Left-Right,Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Area(NA) Tributary Area(NA) <br /> CDX J Sheathing type(T4.3A of SDPWS-2015) 1.0 tributary width 1 0 tributary area <br /> 2.0 total width 2.0 total area <br /> ROOF Resisting Dead Load Tributary Area(NA) Tributary Area(NA) <br /> Shearwall S rl1ent Lengths: Adj.Total Length a 30 3 ft Mtributary width 1.0 tributary area <br /> 145ft I 123ft 40ft I I I total width 2.0 total area <br /> Tributary Area(NA) Tributary Area(NA) <br /> EV(ROOF)= 8797 lb 3918 lb (4 tributary width tributary area <br /> EV()= 0 lb 0 lb i 'tributary <br /> width total area <br /> EV O= 0 lb 0 lb <br /> EV()= 0 lb 0 lb Height of Shearwall= 9 0 ft Weight of Shearwall= 10 0 lbs <br /> E(Wind)= 8,797 lb E(Smc)= 3,918 lb Length of Shearwall= 4 0 ft Tributary width for dead load= 3 0 ft <br /> ULT. V= 145 PLF ULT. V= 65 PLF Aspccl Ral.ic OK Length of adjoining wall= alleir <br /> Use alternate R factor for seismic? No R= 6 5 <br /> ASD SHEAR WALL DESIGN PER:AF&PA SDPWS-2015 D0 Holdown Design? No Do=aa <br /> WIND CAPACITY:1.4 x 0.93 x 460 PLF/(2 x 0.6)=499 PLF Ductile Anchor Design? No 1 Block Shear Wall <br /> SEISMIC CAPACITY:1 x 0.93 x 460 PLF/(2 x 0.7)=305 PLF, USE / 1 <br /> Floor Above: NO FLOOR ABOVE 'v'f'ii Cptirrclis 3llc o' a:Citts:g£i <br /> ASD C.TOTAL= (floor above)+(this floor)= 0 lbs + 784 lbs = 784 lbs Wind controls-C1(ASD eq,5): <br /> ASD T. TOTAL w/o D0= (floor above)+(this floor)= 0 lbs + 360 lbs = 360 lbs Wind controls-T1(ASD eq.7): <br /> Unfactored C WL=1306 lbs Unfactored T WL= 1478 lbs NO HOLDOWNS REQUIRED 1 OK j <br /> Unfactored C.EQ=582 lbs Unfactored T EQ=582 lbs j FOUNDATION/INTERIOR WALLS: I OK I <br /> i Unfactored C DL= 878 lbs Unfactored C.LUSL=488 lbs <br /> RIGHT SEGMENTED SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Area(ROOF) Tributary Area(ROOF) <br /> ROOF Floor Level,e.g.Roof,3RD,2ND,1ST.. 1 0 tributary width 1.0 tributary area <br /> Lt-Rt Load Direction,e.g.Left-Right,Front-Rear 2.0 total width 2 O total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Area(NA) Tributary Area(NA) <br /> CDX Sheathing type(T4.3A of SDPWS-2015) 1 0 tributary width 1 0 tributary area <br /> 2 0 total width 2 0 total area <br /> ROOF Resisting Dead Load Tributary Area(NA) Tributary Area(NA) <br /> Shearwall Segment Lengths: Adj Total Length= 37 7 ft 1.0 tributary width Mtributary area <br /> I 377 ft I 00ft I 00ft I J I 2.0 total width total area <br /> Tributary Area(NA) Tributary Area(NA) <br /> EV(ROOF)= 6424 lb 3918 lb 1.0 tributary width 1.0 tributary area <br /> EV()= 0 lb 0 lb 2.0 total width 2 0 total area <br /> EV()= O lb O lb <br /> EV()= 0 lb 0 lb Height of Shearwall= 9.0 ft Weight of Shearwall= 10 0 lbs <br /> E(Wind)= 6,424 lb E(Smc)= 3,918 lb Length of Shearwall= 37 7ft Tributary width for dead load= 3 0 ft <br /> ULT. v= 85 PLF ULT. v= 52 PLF Aspect Ratio OK Length of adjoining wall= 4 5 ft <br /> Use alternate R factor for seismic? No R= 6.5 <br /> ASD SHEAR WALL DESIGN PER:AFBPA SDPWS-2015 DO Holdown Design? No Do= 2.5 <br /> WIND CAPACITY:1.4 x 0.93 x 460 PLF/(2 x 0.6)=499 PLF Ductile Anchor Design? No A Block Shear Wall <br /> SEISMIC CAPACITY:1 x 0.93 x 460 PLF/(2 x 0.7)=305 PLF USE <br /> Floor Above: NO FLOOR ABOVE Wind controls s/i arwa!I design <br /> ASD C.TOTAL= (Floor above)+(this floor)= 0 lbs + 691 lbs = 691 lbs Seismic controls-C3(ASD eq 8): <br /> ASD T.TOTAL w/o D0= (floor above)+(this floor)= 0 lbs + -1060 lbs = -1060 lbs Wind controls-T1(ASD eq.7): <br /> Unfactored C.WL=767 lbs Unfactored T.WL= 1384 lbs ' NO HOLDOWNS REQUIRED I OK i <br /> Unfactored C.EQ=468 lbs Unfactored T.EQ=468 lbs i FOUNDATION/INTERIOR WALLS: I OK 1 <br /> Unfactored C DL= 3150 lbs Unfactored C.LL/SL= 1750 lbs <br />