Installation Wrenches <br /> AM <br /> Model FC Model W3 <br /> For use with Model RFC Series sprinklers For use with Model RFC Series sprinklers with <br /> without wrench-able cap installed wrench-able cap installed <br /> Service/SpareListings and Approvals <br /> Listed by Underwriters Laboratories, Inc. and UL Certified for <br /> Model W8 Canada to UL 199,Automatic Sprinklers for Fire-protection <br /> High-strength plastic wrench Service(cULus). <br /> for limited (emergency) Certified by Underwriters Laboratories, Inc. and Underwriters <br /> use with Model RFC Series Laboratories of Canada for Health Effects to NSF/ANSI Standard <br /> sprinklers without wrench-able 61 Annex G(LL) (RFC30LL, RFC43LL,and RFC49LL only). <br /> cap installed. Meets NFPA <br /> requirements for sprinkler <br /> wrench on premises. Australian WaterMark Certified(RFC30LL, RFC43LL,and <br /> RFC49LL only). <br /> Patents <br /> Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, <br /> RFC58, and RFC76 sprinklers are covered by U.S. Patent No. <br /> Maintenance 9,248,327 and U.S. Patent No. 7,275,603. <br /> Model RFC series sprinklers should be inspected and the Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are <br /> sprinkler system maintained in accordance with NFPA 25. Do additionally covered by U.S. Patent No. 8,776,903. <br /> not clean sprinklers with soap and water, ammonia or any other <br /> cleaning fluids. Remove dust by gentle vacuuming. Replace any <br /> sprinkler cover plate assembly which has been painted (other Ordering Information <br /> than factory applied)or damaged in any way.A stock of spare <br /> sprinklers should be maintained to allow quick replacement of Specify the following when ordering. <br /> damaged or operated sprinklers. Prior to installation, sprinklers <br /> should be maintained in the original cartons and packaging until Sprinkler <br /> used to minimize the potential for damage to sprinklers that would • Model(RFC30, RFC30LL, RFC43, RFC43LL, <br /> cause improper operation or non-operation. RFC49, RFC49LL, RFC58, RFC76) <br /> • Temperature Rating <br /> Guarantee Cover Plate <br /> • Model G5 <br /> •For the Reliable Automatic Sprinkler Co., Inc.guarantee,terms, Temperature RatingFinish (See Table H) <br /> and conditions,visit www.reliablesprinkler.com. Sprinkler Wrench <br /> • Model FC <br /> • Model W3 <br /> • Model W8(Limited use) <br /> rn <br /> rn <br /> rn <br /> rn <br /> rn <br /> z <br /> a <br /> Bulletin 006 Reliable Page 8 of 8 <br /> June 2021 www.reliablesprinkler.com <br />