Laserfiche WebLink
TAYLOR DESIGN ARCHITECTS <br /> PO Box 54, Clear Lake, Washington 98235 <br /> Ph: (360)540-8223 <br /> Email: taylordesignarch@yahoo.com <br /> Date: July 3, 2023 <br /> Ref: Owner name(s):Extended Stay America <br /> Site address: 6410 Broadway <br /> Subject: <br /> Plan review Response <br /> To Whom It May Concern: <br /> Drew Martin <br /> Architectural <br /> 1. The occupancy classification is—R-2 <br /> 2. construction type--VA <br /> 3. The walls are having the sheathing replaced and rebuilt exactly the same as when it was permitted 4. <br /> 4. This building met energy code when originally built the insulation is being replaced with R-21 <br /> insulation <br /> Structural <br /> 1. Plans are now Stamped <br /> 2. Shear wall nailing is added <br /> 3. Wall loading analysis verifies 2x6 16" oc. And two extra studs are added for HDU5's at first level. <br /> 4. HDU5-SDS are added at lower levels, and MSTA48 straps are added through floors to walls above <br /> and below <br /> 5. 5/8"Titen installation can be field verified with 90 lb torque wrench value on installed titen with <br /> HDU5 for buidling inspector if City accepts. Don't torque these over 100# <br /> Al Taylor, Architect <br /> (360)202-7718 <br />