My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
701 COLBY AVE 2025-09-10
>
Address Records
>
COLBY AVE
>
701
>
701 COLBY AVE 2025-09-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 9:04:16 AM
Creation date
8/15/2025 9:40:43 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
701
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF EVERETT <br /> EVE RETT Public Works Department <br /> WASHINGTON <br /> Date: 02/01/2024 <br /> Owner: Timothy R. Crane <br /> Job Address: 701 Colby Ave <br /> Plan Check No: B2312-041/W2312-003 <br /> RE: Building Submission Intake Letter <br /> Hello Timothy, <br /> In response to the application for a building permit,the plans have been examined and you are advised <br /> that revisions are required before a review may begin. Please review and respond to the comments <br /> below: <br /> General: <br /> 1. Drawing clarity: A few items are missing from the drawings to substantiate ample clarity for <br /> construction as required by Sections R106.1.1 and R106.2 of the 2018 WRC, and Section 107.2.1 <br /> of the 2018 WBC. Please provide the listed items below: <br /> a. Please label and indicate the individual new and existing elements to better communicate <br /> the design intent and existing condition per Section R106.2 of the 2018 WRC. <br /> b. Provide missing typical details and connecting elements to alleviate the possibility of <br /> miscommunication between construction and design intent. <br /> c. Please show on plan or in detail how the new members are to be secured to the existing <br /> structural elements. <br /> 2. Dead-end detail references: please provide the details associated with the section cut symbols <br /> provided on the proposed floor plan; namely, Section 1/S1 and 2/S1. <br /> a. Missing plans: The detail references mentioned in general comment (1) above refer to a <br /> structural sheet that is missing from the plan set. Please provide the missing sheet or <br /> clarify what the section cuts refer to. <br /> 3. Please provide general structural notes on the front page of the calculations including applicable <br /> special inspections for the anticipated concrete work during construction. These provisions can <br /> be found in Table 1705.3 of the 2018 WBC/IBC.A few items which may be relevant depending on <br /> design intent and construction: <br /> a. The special inspections required for placement of concrete reinforcement and/or cast-in- <br /> place anchors noted in list items (1) and (3) of Table 1705.3, respectively. <br /> b. The frequency and nature of the special inspections required for post-installed anchors in <br /> hardened concrete members per Table 1705.3 (List item 4a or 4b) <br /> 3200 Cedar Street ` 425.257.8810 W <br /> PermitServices@everettwa.gov <br /> Everett,WA 98201 everettwa.gov/permits <br />
The URL can be used to link to this page
Your browser does not support the video tag.