Specifications <br /> EE D WARDS Catalog Number SIGA-CT1 HT I SIGA-CT1 SIGA-CT2 I SIGA-MCT2 <br /> Description Single Input Module Dual Input Module <br /> LIFE SAFETY&INCIDENT MANAGEMENT Type Code 48(factory set)Four sub-types 49(factory set)Four sub-types <br /> (personality codes)are available (personality codes)are available <br /> Contact us... Address Requirements Uses One Module Address Uses Two Module Addresses <br /> Email: edwards.fire@fs.utc.com Operating Current Standby=250pA; Standby=396NA; <br /> Web: edwards-fire.com Activated=400pA IActivated=680pA <br /> 1016 Corporate Park Drive Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) <br /> Mebane,INC 27302 Construction High Impact Engineering Polymer <br /> EDWARDS is a registered mark in the Mounting North American 21/2 inch(64 mm)deep one-gang box- U102R/6R/6 <br /> United States and other countries. es and 11/2 inch (38 mm)deep 4 inch square boxes Motherboard <br /> ©2018 United Technologies Corporation. with one-gang covers and SIGA-MP mounting plates <br /> All rights reserved. Operating Environment 32°F to 158°F 32°F to 120°F(0°C to 49°C) <br /> (0°C to 70°C) <br /> Storage Environment -4°F to 140°F(-20oC to 60oC);Humidity:0 to 93%RH <br /> LED Operation On-board Green LED-Flashes when polled;On-board Red LED- <br /> Flashes when in alarm/active. <br /> Compatibility Use with Signature Loop Controller <br /> Agency Listings UL,ULC,MEA,CSFM <br /> Ordering Information <br /> Catalog Description Ship Wt. <br /> Number Ibs(kg) <br /> SIGA-CT1 Single Input Module— UL/ULC Listed 0.4(0.15) <br /> SIGA-CT1 HT Single Input Module High Temperature Operation UL/ULC Listed 0.4(0.15) <br /> SIGA-CT2 Dual Input Module— UL/ULC Listed 0.4(0.15) <br /> —0 SIGA-MCT2 Dual Input Plug-in(UIO)Module — UL,ULC Listed 0.1 (0.05) <br /> Related Equipment <br /> 27193-11 Surface Mount Box-Red, 1-gang 1.0(0.6) <br /> 27193-16 Surface Mount Box-White, 1-gang 1.0(0.6) <br /> SIGA-U102R Universal Input-Output Module Board w/Riser Inputs 0.32(0.15) <br /> —Two Module Positions <br /> SIGA-U106R Universal Input-Output Module Board w/Riser Inputs 0.62(0.28) <br /> —Six Module Positions <br /> SIGA-U106 Universal Input-Output Module Board —Six Module Positions 0.56(0.25) <br /> MFC-A Multifunction Fire Cabinet— Red,supports Signature Module 7,0(3.1) <br /> Mounting Plates <br /> SIGA-MB4 Transponder Mounting Bracket(allows for mounting 0.4(0.15) <br /> two 1-gang modules in a 2-gang box) <br /> SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5(0.70) <br /> SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5(0.23) <br /> SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02(0.46) <br /> N <br /> Page 4 of 4 DATA SHE, E85001-0241 <br /> Not to be used for instal, i purposes. Issue 1 <br />